9
Wiring
WARNING:
Turn off the breaker until all electrical
connections are made.
WARNING:
This unit must be connected to a
protective grounding system.
Before attempting system installation, verify that
the electrical system and wiring are adequate
for supplying the required ampacity to the air
handler unit at 120 VAC. Refer to the air handler
specifications section of this document for the air
handler ampacity information. Field wiring
terminals are provided for power and control
connections. If you aren’t familiar with local
building codes and standard electrical practices.
You MUST employ the services of a qualified
electrician prior to installing and operating the
equipment. Making improper electrical
Installation Connections
connections could cause damage to the
equipment or servicing personnel. When installing
the power wiring, verify that the line conductor is
connected to the terminal marked “L”, and the
Neutral conductor is connected to the terminal
marked “N”.
A thermostat was provided installed on your unit.
If you elect to use an alternate thermostat or
control device, you can remove the pre-installed
thermostat and easily install an alternate. With
power removed from the air handler unit at the
breaker or main disconnect, remove the cover
of the electrical box using a screwdriver. Once
open, disconnect the thermostat leads from
the low voltage terminal block. Using the same
routing as the factory installed thermostat, wire
the new control device into the terminal blocks
“COM” and “SW1” terminals.
Installation Connections
A – Ground Terminal
B – Line Terminal
C – Neutral Terminal
D – Thermostat Control Terminal Block
A
B
C
D