18
Operating the Device
EN
5.4
Display
The above depicted display shows all displays and keys. Additional explanations
for individual elements are presented in the subsequent respective control ele-
ment descriptions.
Not all displays and functions are available for all modes.
5.5
Switch Device On
1. Plug the device into the power outlet.
2. Connect the gas supply to the gas connection port and open the gas supply.
3. Make sure
no
tube set is connected before switching the device on.
4. Press the
ON/OFF
switch (see Fig. 5-1 "Front of the Device"
(1)
). The device
now initializes and then runs the initial self test. The start screen and a prog-
ress bar are depicted on the display during the initial self test.
If the initial self test was unsuccessful, an error message and information
about how to possibly remedy the problem are displayed. An acoustic warn-
ing signal is emitted (see 12 "Informational, Warning and Error Messages").
5. The message
Device ready
is shown after the successful initial self test. An
acoustic signal is emitted and the display depicts
Mode Selection
.
NOTE!
After the successful initial self test, factory-new devices will request the user se-
lect a language. Press the desired language.
6. Press the respective key to choose the desired operating mode (e.g.
Smoke
Evacuation Mode
).
Press the
Information symbol
for a short instruction about the desired oper-
ating mode. Tutorials for the three insufflation operating modes are avail-
able.
Fig. 5-4
Display
(1)
Nominal gas flow rate level 1
(2)
Actual flow rate display
(3)
Nominal gas flow rate level 2
(4)
Nominal gas flow rate level 3
(5)
Decreasing nominal pressure
(6)
Actual pressure display
(7)
Nominal pressure display
(8)
Increasing nominal pressure
(9)
Gas supply display
(10)
Gas Consumption Display
(11)
Reset key for consumption display
(12)
Smoke gas evacuation level LOW
(13)
Smoke gas evacuation status
(14)
Smoke gas evacuation level HIGH
(15)
Status display/error & warning
messages
(16)
Mode
(17)
START/STOP key
(18)
MENU key
(19)
HOME key
(3)
(2)
(1)
(9)
(4)
(7)
(6)
(5)
(8)
(10)
(11)
(14)
(17)
(18)
(16)
(12)
(13)
(19)
(15)
(2)
(1)
Содержание AirSeal iFS
Страница 1: ...EN Instructions for use...
Страница 4: ......
Страница 6: ...2 EN 15 AirSeal iFS Warranty 52 16 Test Log 53 16 1 Test Log 53 16 2 Return Form 54 Index 55...
Страница 20: ...16 Initial Device Startup EN House gas supply pressure OK House gas supply pressure too low...
Страница 57: ...Test Log 53 EN 16 Test Log 16 1 Test Log Date Results Comment Signature...
Страница 60: ...W55 186 EN AA...