SAFETY PRECAUTIONS 2

This product complies with the maximum allowable concentration of ozone of 0.050 parts per million by volume 

(ppmv) in a 24-hour period. The Health Canada Guideline 2010 recommends that the maximum exposure limit,

 

based on an averaging time of 8 hours, is 0.020 ppmv or less when tested in a sealed, controlled room

 

approximately 30 m³.

Ce produit est conforme avec la concentration maximale permise d’ozone de 0,050 parties par million par

 

volume (ppmv) pendant une période de 24 heures. La Ligne directrice (2010) de Santé Canada recommande un

 

niveau maximal d'exposition, basé sur un moyen de 8 heures, soit 0,020 ppmv ou moins dans une chambre de

 

teste étanchée et contrôlée de 30 m³.

INTENDED USE

 

The JADE

2.0

 Air Purifier is intended to 

capture 

particles and microorganisms from the air. 

UTILISATION PREVUE 

Le purificateur d'air 

JADE2.0

 est destine a 

capturer 

les particules et les micro-organismes de l'air. 

DIRECTIONS FOR USE

Plug the power cord in and you will hear a "Beep". The smallinner circle will turn 

blue

 this indicates the air purifier is in

 

standby mode. Use your hand to wave over the sensor, this waving motion turns the unit on & off, and can also adjust the fan 

speed. 

MODE D'EMPLOI 

Branchez le cordon d'alimentation et vous entendrez un (< bip ». Le petit cercle interieur deviendra vert - ce indique que le 

purificateur d'air est en mode veille. Utilisez votre main pour agiler le capteur, ce mouvement d'ondulation allume et eteint 

nite et peut egalement ajuster la vitesse du ventilateur. 

DISPOSAL INSTRUCTIONS 

Dispose of filters and UV

-C+

 bulbs according to local regulations based on location of use (e.g. medical waste if used in 

medical setting 

such as

 dental clinics, laboratories, etc.

). 

INSTRUCTIONS D'ELIMINATION 

Eliminez les filtres conformement aux reglementations locales en fonction du lieu.

Содержание JADE2.0

Страница 1: ...SURGICALL Y CLEAN AIRTM JADE2 0 SCA5100C OPERATION MANUAL Read the manual thoroughly before operation and retain for future reference EPA Establishment 100231CHN001 E520581...

Страница 2: ...TABLE OF CONTENTS SAFETY PRECAUTIONS HOW IT WORKS FEATURES AND SPECIFICATIONS PART NAME INSTALLATION OPERATION CARE AND MAINTENANCE TROUBLESHOOTING 3 5 6 7 8 9 10 12 13 14 15...

Страница 3: ...t block the air intake and air outlet Never insert small things into the air intake outlet Do not use the air purifier if the power cord or plug is damaged or the connection to the wall outlet is loos...

Страница 4: ...ATION PREVUE Le purificateur d air JADE2 0 est destine a capturer les particules et les micro organismes de l air DIRECTIONS FOR USE Plug the power cord in and you will hear a Beep The smallinner circ...

Страница 5: ...radiation is only emitted internally in this device Unintended use of the device or damage to the housing may result in exposure to ultraviolet radiation Ultraviolet radiation may cause eye and skin...

Страница 6: ...IT WORKS When the DC fan motor is running the indoor air will be drawn through the bottom of the unit The air will then pass through the HEPA Rx Filter the Activated Carbon Filter the UV C and Photoca...

Страница 7: ...d UV C Lamp Replacement Indicator Lights The indicator lights tell you when to replace the HEPA Rx filter the Activated carbon filter or the UV C lamp Safety and Easy Maintenance The unit is also equi...

Страница 8: ...aser sensor 10 HEPA Rx filter 11 Activated carbon filter 12 UV C lamp 13 Photocatalytic filter 14 Unit lock 15 UV C lamp set 16 Bottom plate 01 Unit body 02 Unit housing 03 Air outlet 04 Fan motor 05...

Страница 9: ...s pictured below Pic 1 3 After the bottom plate is removed pull out the power cord of the UV C lamp open the unit lock Pic 2 and take out the HEPA Rx filter and the Activated carbon filter to remove t...

Страница 10: ...Wave a 4th time all the circles light up white turbo speed Wave 5 Wave a 5th time the AUTO indicator will light up This is Auto Mode the unit will operate on low speed and will adjust speeds accordin...

Страница 11: ...d humidity Press the button turns the unit On and Off Hold the button for 3 seconds to reset the filters indicator light 2 TIMER Button Press this button to select the time for operation The timer set...

Страница 12: ...3 LOCK Button When pressed all the operation will lock at the desired speed except the NIGHT button 4 NIGHT Button When pressed all the indicator lights on the display panel will go out 5 UV C LAMP B...

Страница 13: ...t the time for the HEPA Rx filter CARE AND MAINTENANCE 1 To maintain optimum performance of this air purifier the HEPA Rx Filter the Activated carbon filter and the UV C lamp need to be replaced when...

Страница 14: ...d from UV C lamp remove screw and then twist to open the UV C lamp set to take out the used UV C lamp 3 Replace with a new one and put new UV C lamp back in the unit close the UV C lamp set re connect...

Страница 15: ...zone Many after market sellers are selling ozone generating UV C bulbs TO ORDER FILTERS OR UV C BULBS www surgicallycleanair com MODEL JADE2 0 SCA5100C Power failure Power plug disconnected Bottom pla...

Страница 16: ...1A 6300 Viscount Road Mississauga Ontario Canada L4V 1H3 Tel 1 877 440 7770 www surgicallycleanair com info surgicallycleanair com SURGICALL Y CLEAN AIRTM...

Отзывы: