The SurgeX

®

 XR315 is a 120V, 15 Amp AC power quality product incorporating SurgeX

® 

Advanced Series Mode

®

 

 power conditioning and surge protection. The surge protection is rated 

A-1-1, the highest standard of the Federal Commercial Item Description for Endurance. The one 
rack-space steel enclosure is designed to be installed in a 19 inch equipment rack, or placed on a 
flat surface. A total of eight 120V receptacles are provided on the rear panel. 

SurgeX ICE

®

 Inrush Current Elimination circuitry is incorporated into the XR315. This 

eliminates problems associated with inrush currents from large loads such as amplifiers. With 
SurgeX ICE

®

 

 it is not necessary to take inrush currents into account when designing the AC 

power for a system, and special time-delay circuit breakers are not required: you only need to 
ensure that the steady-state currents of all products plugged into the XR315 are within the 15 
Amp rating. 

The front panel houses a two-line back-lit LCD display which provides status information in 
normal use and allows interaction with menu items during programming. The character display 
intensity is adjusted by either a rotary dimmer knob or a push-button On/Off switch. Also on the 
front panel are two screwdriver-accessible rotary encoders which are used to step through and 
select from a menu of items which determine the operation of the unit. The power button, when 
pressed, causes the unit to power up or power down. This button can be disabled if not required. 
The LED incorporated into the button indicates the status of the unit. When the LED is off the 
unit is fully powered down; when it is on the unit is fully powered up; when it is flashing the unit 
is in the process of powering up or down. 
 
A built-in AC voltmeter indicates the line voltage on the LCD display. The internal voltmeter is 
a peak reading type which was chosen because most electronic equipment incorporates a power 
supply that charges mostly during the AC peaks. Monitoring the peak of the AC provides a more 
useful indication of the real voltage available to the electronic equipment plugged into the 
XR315. 
 
A built-in AC ammeter indicates the total current consumption of connected equipment on the 
LCD display.  The internal ammeter is also a peak reading type.   
 
A calculation of the total power being delivered to connected equipment is displayed on the 
second line of the LCD display.  Power is calculated as the product of the line voltage and total 
current draw, and is displayed with the unit Watts “W”.  Volt-Amps (“VA”) is the more correct 
unit of power, since the voltage and current measurements are based on a peak reading, but 
Watts is displayed for simplicity. 
 
The XR315 is microprocessor controlled and designed to be versatile and expandable. Two or 
more XR315s can be connected together to provide control and power conditioning for larger 
systems. The XR315 can also control other SurgeX products with its auxiliary relay contacts 
and/or its 12V dc output. All options are set via the front panel and all connections are made at 
the rear panel.  All set-up information is stored in non-volatile memory. 
 

Содержание XR315

Страница 1: ...USER MANUAL SurgeX XR315 SurgeX For Surge Eliminator Residential Applications Software Version 1 0 1 1...

Страница 2: ...OVER RIDE CONTROL 9 5 3 12V DC OUTPUT 10 5 4 AUXILIARY RELAY 11 5 5 FRONT PANEL PUSH BUTTON 11 5 6 OUT OF RANGE AC VOLTAGE SHUT DOWN 12 5 7 RESTORE FUNCTIONS 12 6 APPLICATIONS 12 6 1 GENERAL POINTS 12...

Страница 3: ...button can be disabled if not required The LED incorporated into the button indicates the status of the unit When the LED is off the unit is fully powered down when it is on the unit is fully powered...

Страница 4: ...rogrammable 12 Volt dc output can be used to control other SurgeX products Auxiliary relay or 12 Volt dc output can be programmed to provide confirmation feedback products or drive LEDs Built in AC Vo...

Страница 5: ...e such as a relay or by a switch In this manual the terms momentary and latching are used when describing switches A momentary switch is considered to be a switch which provides a connection only whil...

Страница 6: ...ng Note The front panel button will not operate with options a b or f 3 2 2 Over Ride Input The XR315 has the option of adding an over ride function for purposes such as providing fire safety over rid...

Страница 7: ...n the XR315 is powered up and will be zero when the XR315 is powered down Program 12V dc Output for Confirm Note that the XR315 common terminal is shared between the inputs and the 12V dc output If yo...

Страница 8: ...ion by rotating Adjust 4 If you have connected an LED to the 12V dc output for remote signaling step through the menu until you reach 12V dc Output Then advance Adjust to select LED This selection wil...

Страница 9: ...t up turn Select counter clockwise until the display tells you to press the power button again Doing so saves the new set up information in non volatile memory and puts you back into normal operation...

Страница 10: ...ution product to drive LEDs or to provide feedback to the previous XR315 in a cascaded chain Please see the applications section for full details on setting up an expanded system There are three menu...

Страница 11: ...SurgeX Gang or Cascade is selected when two or more XR315s are ganged or cascaded together All these options are covered in detail in the applications section Aux Delay On Set the delay time in secon...

Страница 12: ...d voltage or latching type remote control inputs Pwr Fail Restore Select Enable if you want the XR315 to power up after a power failure or out of range AC condition and the XR315 was powered up when t...

Страница 13: ...ith multiple control locations they are intended primarily for a small system or for hook up to a central controller The front panel push button will not work with a latching switch contact closure or...

Страница 14: ...d together This is covered in the section on cascaded systems If an over ride is required with a ganged system use the over ride input on the first XR315 If an over ride is required with a cascaded sy...

Страница 15: ...ontrolled by the same inputs as a single unit system Figure 3 shows how the two units are wired together using the aux relay contacts The aux relay contacts on the XR315 terminals 6 7 are connected to...

Страница 16: ...edback source and the over ride input terminal 3 is used as the feedback input Figure 6 shows how to connect and program each unit in a three unit system Note that terminals 5 and 6 are connected toge...

Страница 17: ...R315 Single Unit System Controlled by Momentary Switches Location 3 Location 2 Location 1 Mixer Signal Processing Amplifier Use an LED and 1K W resistor at each location Program Up Down Inputs Momenta...

Страница 18: ...4 5 6 7 XR315 Mixer Signal Processing Amplifier Single Unit System Controlled by Central Controller Program Up Down Inputs Latching Aux Output Confirm Confirmation Feedback Controller Low Voltage Cont...

Страница 19: ...4 5 6 7 XR315 A On Switched 1 2 3 4 5 6 7 SX1120 RT LED and 1K 1 4W Resistor Confirmation If Required Program Up Down Inputs Momentary 12v dc Output LED Aux Output A B or C Aux Delay On Set as Needed...

Страница 20: ...acles 1 2 3 4 5 6 7 XR315 A On Switched 1 2 3 4 5 6 7 SX1120 RT Confirmation If Required Program Up Down Inputs Momentary 12v dc Output A B or C 12V Delay On Set as Needed 12V Delay Off Set as Needed...

Страница 21: ...1 2 3 4 5 6 7 XR315 Receptacles 1 2 3 4 5 6 7 XR315 Program Up Down Inputs One Mom 12V dc Output LED Aux Output Gang Confirmation If Required Program Up Down Inputs Latching Aux Output Gang Program Up...

Страница 22: ...ired LED and 1K 1 4W Resistor Program Up Down Inputs One Mom Over Ride Input 5 30 Vdc Over Ride Func Master 12V dc Output LED Aux Output Cascade Program Up Down Inputs Latching Over Ride Input 5 30 Vd...

Страница 23: ...rtain that power is being supplied to the unit consult the factory for assistance Unit will not power up from remote control connection If you have performed initial checks as above and the unit will...

Страница 24: ...e you can get into the programming mode 8 Error Codes Error codes are displayed on the second line of the display Error 05 The calibration of the AC voltmeter is no longer accurate The unit is otherwi...

Страница 25: ...ry B3 pulses 1 KV 500 000 3 KV 10 000 6 KV 1000 Number of Outlets 8 Remote Control Voltage 5 to 30 Volts dc Remote Control Current Draw 4 mA maximum Contact Closure Max Resistance 100 Ohms Auxiliary R...

Отзывы: