6.2

 

Single Unit System 

 
Most of the information necessary to install and set up a single unit system can be found in 
sections 3.2 and 6.1. Figure 1 shows a single unit system controlled by momentary switches at 
three different locations, and figure 2 shows a single unit controlled by a central controller. 
 

6.3

 

Expanded System 

 
A basic expanded system consists of a XR315 in combination with a remote turn-on SurgeX 
such as the SX1120-RT or the SX20-NE/RT. The auxiliary relay inside the XR315 is normally 
used to control the second unit although the 12V dc output can also be used for this purpose. The 
only difference in these remote control configurations is that, when the aux relay is used to 
control a second unit, it cannot be used for confirmation feedback to a central controller, and 
when the 12V dc output is used for control it cannot be used to drive LEDs.  
 
If more current capability is required then additional SurgeX RT products can be connected to 
the second unit. Connect pins 6 & 7 of the second unit to pins 1 & 2 of the third unit, and so on. 
 
It is possible to configure an expanded system by using both the aux relay and the 12V dc output 
to simultaneously control two separate pieces of equipment or two racks of equipment. In this 
case, refer to both figures 3 & 4 and follow the instructions below. 
 
The XR315 in an expanded system can be controlled by the same inputs as a single unit system. 
Figure 3 shows how the two units are wired together using the aux relay contacts. The aux relay 
contacts on the XR315 (terminals 6 & 7) are connected to the contact closure inputs at the back 
of the RT (terminals 1 & 2). The aux relay must be programmed accordingly. The Aux Output 
menu item must be set to A, B or C. This synchronizes the aux relay to the internal trigger used 
to turn on the receptacles on the rear panel of the XR315. The Aux Delay On and Aux Delay Off 
delay times are then set to the desired turn-on and turn-off delays.  
 
If an over-ride is used with an expanded system do not use the Special Delay. 
 
Figure 4 shows how to configure an expanded system using the 12V dc output instead of the aux 
relay to control external units. This option allows the aux relay to be used for confirmation but it 
is then no longer possible to drive external LEDs from the 12V dc output. The programming and 
delay timing set up follow the same concepts as for the aux relay which is explained above. 
 
 

6.4

 

Ganged System 

 
A ganged system consists of two or more XR315s connected together in such a way that they all 
turn off and on together. Figure 5 shows how to connect and program each unit in a three-unit 
system. If only two units are to be ganged together then ignore the middle unit in the diagram. If 
more than three units are to be ganged together then keep the first and last units set up as shown, 
add units in the middle and set them up and connect them in the same way as the middle unit in 
the diagram. 

Содержание XR315

Страница 1: ...USER MANUAL SurgeX XR315 SurgeX For Surge Eliminator Residential Applications Software Version 1 0 1 1...

Страница 2: ...OVER RIDE CONTROL 9 5 3 12V DC OUTPUT 10 5 4 AUXILIARY RELAY 11 5 5 FRONT PANEL PUSH BUTTON 11 5 6 OUT OF RANGE AC VOLTAGE SHUT DOWN 12 5 7 RESTORE FUNCTIONS 12 6 APPLICATIONS 12 6 1 GENERAL POINTS 12...

Страница 3: ...button can be disabled if not required The LED incorporated into the button indicates the status of the unit When the LED is off the unit is fully powered down when it is on the unit is fully powered...

Страница 4: ...rogrammable 12 Volt dc output can be used to control other SurgeX products Auxiliary relay or 12 Volt dc output can be programmed to provide confirmation feedback products or drive LEDs Built in AC Vo...

Страница 5: ...e such as a relay or by a switch In this manual the terms momentary and latching are used when describing switches A momentary switch is considered to be a switch which provides a connection only whil...

Страница 6: ...ng Note The front panel button will not operate with options a b or f 3 2 2 Over Ride Input The XR315 has the option of adding an over ride function for purposes such as providing fire safety over rid...

Страница 7: ...n the XR315 is powered up and will be zero when the XR315 is powered down Program 12V dc Output for Confirm Note that the XR315 common terminal is shared between the inputs and the 12V dc output If yo...

Страница 8: ...ion by rotating Adjust 4 If you have connected an LED to the 12V dc output for remote signaling step through the menu until you reach 12V dc Output Then advance Adjust to select LED This selection wil...

Страница 9: ...t up turn Select counter clockwise until the display tells you to press the power button again Doing so saves the new set up information in non volatile memory and puts you back into normal operation...

Страница 10: ...ution product to drive LEDs or to provide feedback to the previous XR315 in a cascaded chain Please see the applications section for full details on setting up an expanded system There are three menu...

Страница 11: ...SurgeX Gang or Cascade is selected when two or more XR315s are ganged or cascaded together All these options are covered in detail in the applications section Aux Delay On Set the delay time in secon...

Страница 12: ...d voltage or latching type remote control inputs Pwr Fail Restore Select Enable if you want the XR315 to power up after a power failure or out of range AC condition and the XR315 was powered up when t...

Страница 13: ...ith multiple control locations they are intended primarily for a small system or for hook up to a central controller The front panel push button will not work with a latching switch contact closure or...

Страница 14: ...d together This is covered in the section on cascaded systems If an over ride is required with a ganged system use the over ride input on the first XR315 If an over ride is required with a cascaded sy...

Страница 15: ...ontrolled by the same inputs as a single unit system Figure 3 shows how the two units are wired together using the aux relay contacts The aux relay contacts on the XR315 terminals 6 7 are connected to...

Страница 16: ...edback source and the over ride input terminal 3 is used as the feedback input Figure 6 shows how to connect and program each unit in a three unit system Note that terminals 5 and 6 are connected toge...

Страница 17: ...R315 Single Unit System Controlled by Momentary Switches Location 3 Location 2 Location 1 Mixer Signal Processing Amplifier Use an LED and 1K W resistor at each location Program Up Down Inputs Momenta...

Страница 18: ...4 5 6 7 XR315 Mixer Signal Processing Amplifier Single Unit System Controlled by Central Controller Program Up Down Inputs Latching Aux Output Confirm Confirmation Feedback Controller Low Voltage Cont...

Страница 19: ...4 5 6 7 XR315 A On Switched 1 2 3 4 5 6 7 SX1120 RT LED and 1K 1 4W Resistor Confirmation If Required Program Up Down Inputs Momentary 12v dc Output LED Aux Output A B or C Aux Delay On Set as Needed...

Страница 20: ...acles 1 2 3 4 5 6 7 XR315 A On Switched 1 2 3 4 5 6 7 SX1120 RT Confirmation If Required Program Up Down Inputs Momentary 12v dc Output A B or C 12V Delay On Set as Needed 12V Delay Off Set as Needed...

Страница 21: ...1 2 3 4 5 6 7 XR315 Receptacles 1 2 3 4 5 6 7 XR315 Program Up Down Inputs One Mom 12V dc Output LED Aux Output Gang Confirmation If Required Program Up Down Inputs Latching Aux Output Gang Program Up...

Страница 22: ...ired LED and 1K 1 4W Resistor Program Up Down Inputs One Mom Over Ride Input 5 30 Vdc Over Ride Func Master 12V dc Output LED Aux Output Cascade Program Up Down Inputs Latching Over Ride Input 5 30 Vd...

Страница 23: ...rtain that power is being supplied to the unit consult the factory for assistance Unit will not power up from remote control connection If you have performed initial checks as above and the unit will...

Страница 24: ...e you can get into the programming mode 8 Error Codes Error codes are displayed on the second line of the display Error 05 The calibration of the AC voltmeter is no longer accurate The unit is otherwi...

Страница 25: ...ry B3 pulses 1 KV 500 000 3 KV 10 000 6 KV 1000 Number of Outlets 8 Remote Control Voltage 5 to 30 Volts dc Remote Control Current Draw 4 mA maximum Contact Closure Max Resistance 100 Ohms Auxiliary R...

Отзывы: