Surge master SM2500CH Скачать руководство пользователя страница 5

5

SERIAL NUMBER LOCATION

Always reference the serial number of your SurgeMaster generator when ordering parts or requesting ser-

vice or other information.

The serial number plate is located where indicated. Please mark the numbers in the spaces provided for 

easy reference. (Serial label location is the same for ALL models)

SERIAL NUMBER LOCATION

Emergency Power Series or Contractor ReadySeries Portable Gas Generator 

Model Number  ____________________________________________________

Serial Number  ____________________________________________________

safety alert 

message

safety label

LABELLING INFORMATION

As you begin to get familiar with your SurgeMaster product, you will notice that there are numerous labels 

located on the machine. Here is a brief explanation of what they are for and how to read them.
There are three different types of labelling: safety, informative 

and product labels. 

Safety Labels

 are pictorial and always with a yellow back-

ground colour and generally 2 panel. The top panel shows the 

safety alert (the potential hazard) and the bottom panel shows 

the message (how to avoid the hazard).

Informative Labels

 are generally pictorial, have a white back-

ground colour and can vary to the number of panels. The label 

will illustrate the function of a feature and is accompanied by detailed instructions in the owners manual, 

with the label illustrated along side.  

Product Labels

 are associated with the product and carry various messages. (model, serial, etc)

See the section on safety signs for safety label definitions. For a complete illustration of labels and label 

locations, download the parts manual for your model product at www.surgemaster.ca. 

Serial Location

Содержание SM2500CH

Страница 1: ...wing this manual for safe and proper operation Keep this manual with the Generator at all times EMB Manufacturing Inc 4144 Boomer Line St Clements On N0B 2M0 Canada Ph 519 699 9283 Fax 519 699 4146 ww...

Страница 2: ...000GFI 23 SM5000CH 23 CIRCUIT BREAKERS 24 GFCI OUTLETS 24 OPERATING HINTS 24 4 6 ELECTRICAL LOAD 25 4 6 1 BALANCING LOADS 25 4 6 2 WATTAGE AND LOAD 25 REACTIVE LOAD 25 RESISTIVE LOAD 25 CONTINUOUS WAT...

Страница 3: ...contact your local engine dealer Under no circumstances will the manufacturer be liable for any consequential damage or expense of any kind including loss of profits The manufacturer is under no circ...

Страница 4: ...w surgemaster ca _________________________________________ Customer s Name _________________________________________ Contact Name _________________________________________ Dealer Name _________ ______...

Страница 5: ...e Here is a brief explanation of what they are for and how to read them There are three different types of labelling safety informative and product labels Safety Labels are pictorial and always with a...

Страница 6: ...of power outage or when the need arises The emergency power series is intended to be connected directly to the appliance equipment requiring electrical power It is not recommended to connect these gen...

Страница 7: ...3 or Fax 519 699 4146 DANGER Indicates an imminently hazardous situation that if not avoided will result in death or serious injury This signal word is to be limited to the most extreme situations typ...

Страница 8: ...ine An untrained opera tor is not qualified and exposes himself and bystanders to possible serious injury or death It is the owners responsibility to the operator to ensure familiarity and understandi...

Страница 9: ...e safety instructions with all users annually 5 This equipment is dangerous to children and persons unfamiliar with its operation The operator should be a responsible properly trained and physically a...

Страница 10: ...careless injuries Read this manual before assembly or using to acquaint yourself with the machine If this machine is used by any person other than yourself or is loaned or rented it is the machine ow...

Страница 11: ...l Each of the Safety Messages found on the safety signs on the engine and machine 2 Personal protection equipment including safety glasses safety shoes gloves hearing protection are recommended during...

Страница 12: ...ke sure that any spilled fuel has been wiped up before starting the engine 2 5 MAINTENANCE SAFETY 1 Good maintenance is your responsibility Poor maintenance is an invitation to trouble 2 Follow good s...

Страница 13: ...you cannot smell or see Breath ing carbon monoxide can be lethal 8 Do not operate near openings to any building that can be occu pied in order to help avoid the exhaust hazard 9 Never use alcoholic be...

Страница 14: ...e stored machine 5 Place the generator on a level surface Tilt ing or laying it on its side can cause fuel or oil leakage Support the frame with planks if required 6 Allow the engine exhaust to cool A...

Страница 15: ...gine starts 15 DO NOT strike flywheel with a hard object or metal tool as this may cause flywheel to shatter in operation Use proper tools to service engine 16 DONOToperateenginewithoutamuffler Inspec...

Страница 16: ...yone else to use this generator until such information has been reviewed Annually review this information before the season start up Make these periodic reviews of SAFETY and OPERATION a standard prac...

Страница 17: ...e The most important safety device on this equipment is an informed SAFE operator 3 2 SAFETY SIGN EXPLANATIONS 3 1 HOW TO INSTALL SAFETY SIGNS Be sure that the installation area is clean and dry Be su...

Страница 18: ...nd windows are open N employerJAMAIS dans la maison ou dans des secteurs partiellement inclus tels que des garages M ME SI les portes et les fenetres soient ouvertes Only use OUTSIDE and far away from...

Страница 19: ...rvicing adjusting or repairing To prevent electrical shocks do not operate this generator in the rain or with wet hands Generatorshouldbekeptdryandnotoperated on wet or damp surfaces Close and secure...

Страница 20: ...tral bonded to the frame The entire assembly is mounted within the frame for added protection and convenient access Alternator Outlets Circuit Breaker Engine see Controls sec tion and engine own ers m...

Страница 21: ...checklist is provided for the opera tor It is important for both the personal safety and maintaining good mechanical condition that this checklist is followed Before operating the SurgeMaster Portabl...

Страница 22: ...the engine Turn the valve on when running the engine and off when refuelling or not in use 4 5 1 ENGINE CONTROLS Always read the engine operator s manual supplied with the machine to familiarize yours...

Страница 23: ...120v power each protected by a 20 amp pop up breaker SM5000CH One four prong twist lock outlet is used to provide 120 240Volt protectedbytwo20amppopupbreak ers One split duplex outlet for 120v protec...

Страница 24: ...the source of the imbalance and correct depress the extended GFCI button to reset turn on or reconnect the load OPERATING HINTS Position frame on a level area to minimize the chance of spilling fuel...

Страница 25: ...require up to 3 x its running watts at start up In other words wattage will spike at starting and level off to running continuous wattage when it is operating normally See wattage chart RESISTIVE LOAD...

Страница 26: ...0 Television tube 43 flat screen 300 190 300 190 Drill 3 8 4 amps 600 440 Air Conditioner 10000 BTU 2200 1500 Drill 1 2 5 4 amps 900 600 Laptop Computer 200 250 200 250 Desktop Computer 600 800 600 80...

Страница 27: ...not operate this generator in the rain or with wet hands Generatorshouldbekeptdryandnotoperated on wet or damp surfaces Close and secure all guards deflectors and shields before starting and operatin...

Страница 28: ...shorts Use properly rated grounded 3 prong extension cords tools and appliances Do not operate at temperatures above 100 F 40 C to prevent overheating of the engine or generator Always run for a few m...

Страница 29: ...er outage is to use a portable generator and run extension cords into the house to power chosen appliances Never connect a generator to a house electrical system without an appropriate transfer switch...

Страница 30: ...r 6 months follow the engine manufactur ers recommendations for storage preparation 6 Store the machine inside in cool dry area Avoid storage areas with high humidity because that promotes rust and co...

Страница 31: ...L 1 4 US gal 3 Storing Lubricants Your machine can operate at top efficiency only if clean lubricants are used Use clean containers to handle all lubricants Store them in an area protected from dust...

Страница 32: ...y use only new genuine parts for repair and replacement Genuine factory replacement parts must be used to restore your equipment to original specifications The manufacturer will not be responsible for...

Страница 33: ...3 4 3 4 3 4 3 Weight kg lbs 68 150 85 187 4 122 269 68 150 85 187 5 122 269 Dimensions length width height Inch cm 22 x16 x16 55 8 x 40 6 x 40 6 22 x16 x16 55 8 x 40 6 x 40 5 25 5 x20 x21 64 7 x 50 8...

Страница 34: ...72 110 155 215 390 570 850 9 19 33 53 80 115 160 290 420 630 17 36 63 100 155 220 305 540 880 1320 12 27 45 75 115 165 220 400 650 970 8 8 N m lb ft Bolt Torque Bolt Diameter A 10 9 N m lb ft M3 M4 M5...

Страница 35: ...ne is off Breaker tripped Reset breaker GFCI correct reason for breaker trip replace if defective Ensure machine is off Alternator problem Check connections receptacles at control panel inspect altern...

Страница 36: ...rd For SM5000CH Generator Extention cord the right length and size to make the most of your generator Heavy Duty SJTW Cable 40 cold weather jacket Nema L14 30P 30a 125 250v Plug Nema L14 30R 30a 125 2...

Страница 37: ...S 28 I IGNITION SWITCH 22 IMPROPER MAINTENANCE 32 INSPECTION 4 L L14 30R 23 LABELING 5 LABELLING INFORMATION 5 LUBRICANTS 31 M MAXIMUM WATTAGE 25 N NEUTRAL BONDED TO FRAME 6 29 NOISE 11 O OIL 31 OIL A...

Отзывы: