background image

Insert Wire Rope

Clamp Lever 

Engaged

Attach 

Telescopic 

Handle

Safety Latch

Correct

Correct

Incorrect

Incorrect

Figure 5.

Figure 4.

Figure 3.

Figure 2.

5

INSERTING WIRE ROPE

1.  Release the clamp by pushing the clamp lever securely into 

the notch on the puller body.

2.  Insert the end of the wire rope into the rope inlet at the  

rear of the puller. Feed the wire rope through until it emerges  
at the other end.

3.  Pull the wire rope through by hand to take up the slack and 

make sure the exit point is not obstructed.

4.  While keeping the wire rope taut, push down on the clamp 

lever and allow it to spring back to its natural position.  
This will engage the wire rope within the puller.

5.  Mount the telescopic handle to either the forward or reverse 

lever, according to the action desired. Rotate the handle  
until it is secure on the lever.

6.  The puller is now ready to operate.

OPERATION

The grip puller uses standard ASA wire rope and may be used 
in any position to lift, pull, lower or stretch heavy loads. Before 
attempting operation of this product, you should become 
thoroughly familiar with the warnings on page 3.

To operate the grip puller:

1.  Place load cable(s) in the middle of the hook and inside the 

safety latch. DO NOT attach any cables outside the safety latch 
on either the puller hook or the wire rope hook. 

2.  Lay out the wire rope correctly without twisting. Twisting the 

wire rope reduces its strength. See Figure 5.

3.  To send the wire rope forward, set the telescopic handle on the 

forward lever and move it back and forth.

4.  To send the wire rope backward, set the telescopic handle on 

the reverse lever and move it back and forth.  
IMPORTANT: A shear pin is installed in the forward lever. If the 
load being handled is too excessive for the puller’s capacity, 
the shear pin is designed to break. If this occurs, decrease 
the load or use other equipment of higher pulling capacity.
 
The broken shear pin is easily replaced using one of the spare 
shear pins which are found within the hand grip of the pullers. 
See Figure 1.

Before storing the grip puller: 

1.   After use, remove the wire rope from the main body by setting 

the clamp lever into the notch (disengage clamp), then pulling 
the wire rope from the inlet side at the rear of the puller. 

2.  After the wire rope is removed, push the clamp lever out of the 

notch and let it snap back to its original position. If the clamp 
lever is kept in the notch for an extended time period, its spring 
may become stretched. 

3.  Wipe off any sand or water from the puller body, including 

internal mechanisms, and the wire rope, then apply oil  
liberally to both. 

4.  Store the grip puller away from rain, dew, high humidity areas 

or around acidic chemicals, which will promote rusting. 

M18-MH111136-38-Eng+Fre-FA.indd   5

2018-07-23   4:11 PM

Содержание JET 111136

Страница 1: ...M18 MH111136 8 Operator s MANUAL JGP SERIES GRIP PULLERS Prod No 111136 111137 111138 M18 MH111136 38 Eng Fre FA indd 1 2018 07 23 4 11 PM ...

Страница 2: ...efect or failure It is the customer s responsibility to provide this information JET shall not be held liable for any consequential or incidental damages for breach of any expressed or implied warranty on their products No claim for damages or any type will be considered and all products are sold with this understanding Any costs incurred to obtain warranty consideration or services are the Custom...

Страница 3: ...o not apply WARNINGS 1 Read and understand owner s manual before operating grip puller Familiarize yourself with the content of the warning label on your puller 2 Do not exceed rated capacity 3 Supporting structure used with this device must provide adequate support to handle all puller operations plus the weight of the puller and attached equipment If in doubt consult a registered structural engi...

Страница 4: ...oil to the puller mechanisms while continuously operating the reverse lever This will help spread the oil to the internal parts Use special care to oil pawls and links well A wear resistant oil is recommended CAUTION Without proper lubrication the pawls will fail to engage the wire rope and the wire rope will not move The above specifications were current at the time this manual was published but ...

Страница 5: ...ller hook or the wire rope hook 2 Lay out the wire rope correctly without twisting Twisting the wire rope reduces its strength See Figure 5 3 To send the wire rope forward set the telescopic handle on the forward lever and move it back and forth 4 To send the wire rope backward set the telescopic handle on the reverse lever and move it back and forth IMPORTANT A shear pin is installed in the forwa...

Страница 6: ...tical in shape The clamp is deformed Trouble Probable Cause Remedy Insufficient lubrication Oil the puller and wire rope Wire rope will not move in either direction Puller is dirty Disassemble and clean out dust dirt or other foreign matter Oil the puller after reassembly Clamp lever is not in proper position Release clamp lever from notch and allow it to return to engaged position Clamp lever is ...

Страница 7: ...7 JGP75A 3 4 T GRIP PULLER PARTS BREAKDOWN PROD NO 111136 M18 MH111136 38 Eng Fre FA indd 7 2018 07 23 4 11 PM ...

Страница 8: ... SGP75A COVER 1 8110 PWC SGP75 818 SGP75 SHEAR PIN 1 8111 PWC SGP75 808 SGP75 ROPE GUIDE 1 8112 PWC SGP75 8112 SPG75A UPPER DUST SHIELD 1 8113 PWC SGP75 8113 SPG75A LOWER DUST SHIELD 1 8114 PWC SGP75 8114 SGP75A NAME PLATE 1 8115 PWC SGP75 8115 SGP75A RIVET 8 8116 PWC SGP75 8116 SGP75A INSTRUCTION PLATE 1 8202 PWC SGP75 804 SGP75 CRANK AXLE 2 8206 PWC SGP75 816 SGP75 SHAKE ROD W 819 OPERATING LEVE...

Страница 9: ...9 JGP150A 1 1 2 T GRIP PULLER PARTS BREAKDOWN PROD NO 111137 M18 MH111136 38 Eng Fre FA indd 9 2018 07 23 4 11 PM ...

Страница 10: ...SHAKE ROD USE 1619 1 16209 PWC SGP150 18 SGP150A SHEAR PIN 1 16301 PWC SGP150 1631 SGP150 TELESCOPIC HANDLE 1 16401 PWC SGP15 16401 SGP150A SNAP RING 2 16402 PWC SGP150 1615 SGP150 RELEASE HANDLE PIN 1 16403 PWC SGP150 1610 SGP150 RELEASE HANDLE 1 16501 PWC SGP150 1612 SGP150 REVERSE LEVER 1 16502 PWC SGP150 1614 SGP150 CONNECTING AXLE 1 16503 PWC SGP150 1613 SGP150 CONNECTING ROD 1 16504 PWC SGP1...

Страница 11: ...11 JGP300A 3 T GRIP PULLER PARTS BREAKDOWN PROD NO 111138 M18 MH111136 38 Eng Fre FA indd 11 2018 07 23 4 11 PM ...

Страница 12: ...INSTRUCTION PLATE 1 32201 PWC SGP300 32201 BUSH FOR CRANK AXLE NO LONGER USED 32202 PWC SGP300 3204 CRANK AXLE 2 32203 PWC SGP300 3220 CONNECTING ROD AXLE 2 32204 PWC SGP30 32204 BUSH FOR OPERATING HANDLE AXLE 2 32205 PWC SGP300 3221 OPERATING HANDLE AXLE 1 32206 PWC SGP300 3219 OPERATING LEVER 1 32207 PWC SGP300 3217 CONNECTING ROD 1 32208 PWC SGP300 3216 SHAKE ROD 1 32209 PWC SGP150 18 SHEAR PIN...

Отзывы: