5477Y1 Sentinel Row Control Manual
©2022 SurePoint Ag Systems 7
4/29/2022
D
Wiring & Elec.
SurePoint Harness Layout for ISO Sentinel
C
Components
CAN/Power in
CAN/Power out
(terminate or connect
to other ISO device))
M
e
te
r B
u
s 1
M
e
te
r B
u
s 2
Communication
Dust Plug
Terminate or connect
additional trunklines
Terminate or connect
additional trunklines
The Sentinel flowmeter module is chained together
with other modules using the provided trunklines and
then later assigned an implement location within the
display (module addressing). The CANBUS
trunkline is connected to the Sentinel module
through the port labeled
+12Vdc
while the remaining
port is plugged. CAN connections cannot be left
open. When a terminator is removed to plug in a
trunkline, the terminator must be moved to the end of
the trunkline. It is not required to utilize both Bus
connections on the main harness. If Meter Bus 2 is
not used, plug a terminator in to that connector.
Add 4
-
pin
Extension where needed
206
-
04
-
XXXX
CAN trunkline
208
-
06
-
XXXX
Add 4
-
pin
Extension where
needed
206
-
04
-
XXXX
Sentinel Row Control Valve Interface
226
-
01
-
4211Y1
Sentinel Flowmeter Module
204
-
01
-
4625AAGB_B_
When doing the Module Addressing pro-
cess, first plug in all the Sentinel Flowmeter
modules, then go to Valve Module Diag-
nostics and plug in all the Sentinel Row
Control Valve Interface Modules.