14
POWER LED Continuously RED:
This may happen during dark cloudy conditions. The Energiser will automatically lower its
power consumption to continue operation. We also recommend you check your solar
setup. The panel must be clean, facing toward the equator (not east or west), not covered
or experiencing shadowing and should see as much of the sky in all directions as is possible.
POWER LED is OFF:
The Energiser has entered a low power stand-by mode to avoid the battery becoming fully
depleted. This condition might happen if you forgot to switch the Energiser OFF when
putting it into storage. To rectify this, switch the Energise OFF for at least 24 hours. Then, at
the start of a sunny day, place the Energiser in FULL sun and switch ON. As it commences
charging, the Blue LED should flash briefly once per second. If it doesn’t, switch OFF for
another 24 hours then try charging again. If the battery still does not come good, contact
Sureguard for advice. After several hours, the Power LED will go GREEN and the fence
commence working.
Rectifying Fence Faults
FENCE LED Flashing RED:
Perform the following self-test of the Energiser:
1.
Switch OFF the Energiser.
2.
Disconnect the Boundary Wire from the Red and Green Terminals.
3.
Attach a short piece of wire to connect the Red and Green Terminals together.
4.
Switch ON the Energiser. If the Energiser works properly, this test indicates you have
a breakage somewhere on your Boundary Wire. If the Energiser does not pass this
test, then call Sureguard for advice.
FENCE LED Continuously RED:
This indication happens whenever the transmission experiences a fault but then restarts.
The LED Status will reset at midnight or when you switch the Energiser OFF then ON. This
fault could happen during setup if you broke the Boundary Wire. It can also indicate an
intermittent break in the Boundary Wire. You can reset this at any time by switching the
power OFF, waiting 10 seconds, then switching back ON.
NOTE
: The battery only charges while
the Energiser is switched ON.