SureCall | 48346 Milmont Drive, Fremont CA 94538 | 1-888-365-6283 | [email protected]
13
12
Installing Your Hardware
For Each Indoor Panel Antenna:
1. Choose location for mounting antenna on vertical surface. Ideal height off the ground or floor should be
the approximate height of regular cell phone use.
2. Using plate, mark position of desired screw placement with pencil or marker.
3. Screw mounting plate into place with the slide panel protruding towards you.
4. Slide antenna securely onto mounting plate.
5. Connect antenna’s RF cable to the cable connector of one of the 75 ft. lengths of SC-400 cable and run
along route to planned location of your booster’s 4 way splitter.
6. Once all indoor antennas and cables are in place, connect cable runs from indoor antennas to the 4-way
splitter ports
7. Connect the provided 30 ft. of SC-400 cable to the remaining end of the splitter and route cable to the
planned location of your booster.
Note: Be sure to provide enough separation from outdoor antenna (at least 75 ft. is recommended).
Installing Your Hardware
Step 4. Install the Signal Booster
1. When placing the booster, select a location close to a working AC outlet. Do not expose the signal
booster to excessive heat, direct sunlight, moisture, and airtight enclosures.
2. If you’d like to mount the booster to a wall, mark location of screw tabs on the wall in the desired
location. Use supplied screws or appropriate screws for surface of mounting location and drill through
screw tab holes on booster.
3. Connect the outdoor antenna cable to the signal booster connector port marked OUTSIDE and hand-
tighten the connection.
4. Connect the cable coming from the indoor antennas’ 4-way splitter to the booster port marked INSIDE
and hand-tighten the connection.
5. Connect the AC power cord to the signal booster.
6. Connect the plug on the other end of the 110V AC power outlet.
7. Turn the booster’s power switch on.
Note:
If the Power LED does not turn ON or the Alert LEDs continue to flash, (see page 14).This booster is rated for 5-20V input voltage. DO NOT use the booster with
a higher voltage power supply. This can damage the booster, cause personal injury and void your warranty.
Outdoor Omni
Outdoor
Cable
(75 ft.)
Indoor Panel
Indoor Panel
4-Way Splitter
Indoor
Cables
(75 ft.)
Indoor
Cable
(30 ft.)
Planned
booster
location
RF CABLE
SC-400
FLAT SURFACE
MOUNTING PLATE
SCREWS
Indoor
Cables
(75 ft.)
Outdoor
Cable
(75 ft.)
Indoor
Cable
(30 ft.)
Indoor Panel
Indoor Panel
Indoor Panel
Option B
4-Way Splitter
Fusion5X
Power Supply
Indoor Dome
Option A
Option A
Indoor Panel
Option B
Indoor Dome
Outdoor Omni
Note:
If desired surface for installation plate is wood or concrete, wood or masonry screws for L-plate will have to be purchased separately.