background image

71030i DC-DC CONVERTER

INSTALLATION INSTRUCTIONS

LITHO IN USA

INSTRUCTION 180127A 0404

1

6

12

7

CONVERTER CONNECTOR

EV BAT -

EV BAT +

72V, 80V

96V

NOMINAL
BATTERY

BANK

IGNITION

SWITCH

Usually Ignition switch is

already wired into vehicle

Use all 3 pins for GND

TO 12V SWITCHED LOADS

TO 12V UNSWITCHED LOADS

30

AMP

30

AMP

TYPICAL INSTALLATION WITH SWITCHED & UNSWITCHED LOADS

(Total load must be less than 30A)

1.  It is recommended that the batteries be disconnected prior to installation.  

Reconnect the batteries after the installation is complete 

 

2.  Mount converter in a convenient, well ventilated area.   Use 16AWG wire 

with a voltage rating of at least 150V to connect to power source.  Use 
14AWG for the ground and 12V outputs.    
 

3.  Terminal #4, #5, and #6 (“GND 12V”):  Make ground connections first.  

Using 14AWG all three pins must be used for ground connection.  

 

4.  Terminal #7 and #8 (“SW 12V”):  Using 16AWG connect both pins to 12V 

loads.   These pins are switched On/Off with activation of Ignition, Terminal 
#3.   

 

5.  Terminal # 3 (“IGN”):  Using 16AWG connect to a switched 12V source.  For 

always ‘ON’ operation this pin can be connected directly to 12V source.   

 

6.  Terminal #9 and #10 (“UNSW 12V”): Using 14AWG connect both pins to 

12V loads.  These terminals supply continuous 12V power.   

 

NOTE:  THE SUM OF TWO OUTPUT LOADS (12V SWITCHED AND  
12V UNSWITCHED) CANNOT EXCEED 30 AMPS.   

 

7.  Terminal #12 (“72Vin, 80Vin, 96Vin”):  Using 16AWG with a minimum 

rating of 150V, connect to positive terminal of power source.   

 

8.  Terminal #1 (“GND POWER SOURCE”):  Using 16AWG with a minimum 

rating of 150V, connect to negative terminal of power source. 

 

Отзывы: