background image

2

Sufficient space must be provided around this appliance to provide air for combustion and ventilation. Any alterations 
to this unit or its controls may be hazardous.

Do not install this heater in bedrooms or bathrooms.

These instructions should be studied carefully before the installation and operation of this unit. 

The installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code ANSI Z223.1, 1992,
or latest edition.

The installation and repair of this unit should be conducted by a licensed or qualified service person. 

WARNING: This appliance is only for installation in a solid fuel burning fireplace made of non-combustible
materials or approved ventless firebox enclosure.

This appliance must be kept clear from combustible materials, gasoline or other flammable vapors and liquids. 

Solid fuels should not be burned in a fireplace where an unvented room heater is installed.

Keep burner and control compartment clean. See installation and operating instructions accompanying heater.

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies. 

Children should be supervised when they are in the same room as the appliance.

All people should be notified of high surface temperatures of the system to avoid burns or clothing ignition.

This system should be inspected upon installation and annually by a professional service person. It is necessary to 
keep controls, burner and air passageways clear of any debris. 

Do not place any combustible material on or around the appliance.

IMPORTANT INFORMATION

Fireplace sizing guide and BTU information:

BTU Information

Set 

Opening

Front

Rear

Fireplace

Natural Gas

L.P. Gas

Size

Height

Width

Width 

Depth

Max.

Min.

Max.

Min.

18”

18”

22”

18”

12”

34,000

22,000

34,000

22,000

24”/21”

18”

28”

23”

15”

39,000

22,000

39,000

22,000

30”

18”

34”

25”

15”

39,000

22,000

39,000

22,000

This appliance is designed as an unvented room heater when installed in a non-combustible fireplace with the flue damper
closed.

This appliance may be used as a heating appliance only if unvented heating appliances are permitted by local state and
city codes. If unvented heaters are not permitted, then the fireplace vent damper must be locked at the minimum area
required by local codes, or in the absence of local codes, by the latest edition of the National Fuel Gas Code (ANSI Z223.1
or latest edition).

This installation manual contains valuable safety instructions and installation procedures that should be understood before
installation of the unit. The owner of this appliance should keep this instruction manual to refer to in the future. It is the
installer’s responsibility to instruct the owner of this unit in the proper use and maintenance of this appliance. 

DANGER: THIS APPLIANCE, AS ANY GAS-FIRED APPLIANCE, CAN PRODUCE POISONOUS CARBON MONOXIDE,
ALONG WITH OTHER COMBUSTION PRODUCTS. CARBON MONOXIDE, IN STRONG CONCENTRATIONS, CAN
CAUSE SICKNESS, SERIOUS PERSONAL INJURY OR DEATH.

GASEOUS FUELS ARE HIGHLY EXPLOSIVE IN CERTAIN CONCENTRATIONS AND ARE VERY FLAMMABLE. ANY
GAS LEAKS IN THE PLUMBING SUPPLYING GAS TO THIS APPLIANCE CAN LEAD TO FIRE OR EXPLOSION. 

WHEN PROPERLY INSTALLED, USED AND MAINTAINED, THIS APPLIANCE SHOULD NOT PRODUCE CARBON
MONOXIDE IN DANGEROUS QUANTITIES. HOWEVER, SINCE CARBON MONOXIDE CAN BE DEADLY POISONOUS,
THE INSTALLER AND ALL USERS OF THIS APPLIANCE SHOULD READ AND FOLLOW THESE INSTRUCTIONS
CAREFULLY.

Содержание SCVFMR 21

Страница 1: ... IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch Do not use any telephone in your building Immediately call your gas supplier from a neighbor s telephone Follow the gas suppliers instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier This...

Страница 2: ...ng guide and BTU information BTU Information Set Opening Front Rear Fireplace Natural Gas L P Gas Size Height Width Width Depth Max Min Max Min 18 18 22 18 12 34 000 22 000 34 000 22 000 24 21 18 28 23 15 39 000 22 000 39 000 22 000 30 18 34 25 15 39 000 22 000 39 000 22 000 This appliance is designed as an unvented room heater when installed in a non combustible fireplace with the flue damper clo...

Страница 3: ...r must be in place when the appliance is operating unless other provisions for combustion air are provided IMPORTANT During the manufacturing process this appliance is treated with certain coloring agents These agents are not harmful but may produce annoying smoke and smell as they are burned off This is a temporary occurrence that ceases after 10 hours of use During the burning off period provide...

Страница 4: ...during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 PSIG Pressures in excess of 1 2 PSIG will cause damage to the unit FIREPLACE CLEARANCES To guarantee safe installation into a non combustible fireplace certain space requirements must be fulfilled 1 The clearance from the side of the unit to any combustible wall should not be less than 15 1 2 in...

Страница 5: ...solution for leaks Bubbles indicate a leak Repair any leaks and recheck before proceeding DANGER DO NOT USE OPEN FLAME TO TEST FOR LEAKS 2 We suggest you do a test lighting of the burner assembly before you begin log placement Be sure to review all safety precautions in the owner s manual before you light your set 3 Press the on off button to bleed the pilot system after a few seconds you will hea...

Страница 6: ... placement can lead to the production of harmful carbon monoxide while the unit is in operation Be sure that the logs are correctly placed in the notches provided for them There should be no direct impingement of flames on any of the logs WARNING Failure to position the parts specifically approved with this heater may result in property damage or personal injury DECORATIVE STONE The decorative sto...

Страница 7: ...not use any telephone in your building Immediately call your gas supplier from a neighbors telephone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier C Use only your hand to push the touch button controls Never use tools If the touch buttons wi...

Страница 8: ... may take several attempts and up to 5 minutes to light the pilot the first time since there will be air in the gas line 5 Wait fifteen 15 seconds after pilot is lit before adjusting the flame height 6 To increase the flame height push the up arrow on the touch pad until desired flame height is reached See Fig 11 Note Burner has 4 different settings 1 Pilot 2 Low flame 3 Medium flame 4 High flame ...

Страница 9: ...pears while the hand held unit is learning the code See Fig 13 Remote will return to the off position MANUAL MODE 3 To light the pilot press the following buttons See Fig 14 On Off button ON will start blinking Set button while ON is still blinking This turns the unit on in manual mode hand should appear See Fig 14 4 To adjust the flame height in manual mode press See Fig 15 Up button Each press r...

Страница 10: ...ure will start blinking each press lowers the temperature one degree Set button while temperature is still blinking The number of flames automatically adjusts to the correct setting in order to reach the desired temperature Note After a few seconds the display returns to showing the current room temperature 8 To turn the unit off press the following buttons See Fig 18 On Off button OFF will start ...

Страница 11: ...id fuel 6 Use pipe dope on threaded joints of gas piping that is resistant to the action of LP gas 7 Install a manual shut off valve union and 1 8 NPT plugged pressure tap ahead of controls 8 Use soap and water solution when checking for leaks 9 Keep the area around the appliance clear and free of combustible materials gasoline and any flammable or explosive material 10 Follow the lighting and ope...

Страница 12: ...with headache dizziness and or nausea If you experience any of these symptoms appliance may not be working properly Get fresh air at once Have appliance serviced by a qualified service technician Some individuals pregnant woman persons with heart or lung disorders anemia those under the influence of alcohol or those at high altitudes are more likely to be affected by carbon monoxide than others Du...

Страница 13: ... open gas supply valve fully gas line obstruction burner inspection for tube kinks or obstructions inspect burner for dust or debris inspect supply lines for tube kinks or obstructions PARTS LIST Ref Part Name SCVFMR 18 24 21 30 Qty 1 Battery compartment 1 2 Control module 1 3 Touch button controls 1 4 Main regulator 1 5 ODS pilot system 1 6 Burner 1 7 Decorative stone shelf 1 8 Remote control han...

Страница 14: ...nal product All costs for removal and reinstallation are the expressed responsibility of the purchaser For repair or replacement of a defective part or parts contact our customer service department at 1 800 229 5647 You will be asked to provide valid warranty registration proof of purchase and model number It is agreed that any repair or replacement is the exclusive remedy from Sure Heat Manufactu...

Страница 15: ...15 N NO OT TE ES S ...

Отзывы: