Copyright © 2021 Sure Electronics Co., Ltd.
Setting up ICP5
SW1
MODE
FUNCTION
①
USBi
SigmaStudio Programming
②
Remote
APP Control / PC UI Control
1. Set Switches on ICP5
Since we want to realize SigmaStudio
programming function, we need to set SW1 of
ICP5 at
① “
USBi
” at first.
As the target product is JAB3+, whose DSP chip is
ADAU1701, we need to set SW4 at
② “IIC”.
SW4
MODE
FUNCTION
①
SPI
For WONDOM Products with ADAU1452
②
IIC
For WONDOM Products with ADAU1701
2. Connect ICP5 to computer
Do not connect ICP5 with target product now.
Connect ICP5 to the computer with a Type-C
cable.
After connection, run SigmaStudio software and
create a new project.