![SUPREME 38SF Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/supreme/38sf/38sf_owners-manual_1406390036.webp)
33
(approximately 30 pounds). This fireplace has been designed to burn with the door closed. When the
fireplace is being used, the door should remain closed at all times. Failing to do so is a safety hazard,
will damage the fireplace and void the warranty.
WARNING: Do not use fire accelerants to rekindle the fire if the first attempt to start the fire failed. Do
not open the door. Simply reactivate the Activator by pushing it inwards.
NOTE: Sufficient air exchange is necessary for the fireplace to operate properly. Air is required in order to
maintain the combustion of the fireplace. If the house is airtight, the fireplace may not function properly. If the
fireplace is deprived of air, it will be necessary to provide a source of fresh air into the dwelling. This may be
done by using an air exchanger unit or simply by opening a window or a door near the fireplace partially for a
few minutes. Make sure that other equipment such as the kitchen exhaust fans or oil central heating systems
does not affect the fireplace functionality. Large return ducts of central heating systems located in the same
room as the fireplace may affect the proper functioning of the unit and may cause smoking.
5.5 Adding a New Load of Wood
WARNING: Open the door to reload only when the wood has been reduced to embers, otherwise there is a
risk of smoke infiltration into the house.
When the wood has been reduced to embers and there’s no visible flame, you may add a new load.
a) Turn the blower of the fireplace off.
b) Crack the Elegance 42 door open and wait a few moments before opening the door completely.
c) Use your fireplace tools to gather the remaining embers at the center of the firebox.
d) Activate the Activator by pushing it in.
e) Once the embers begin to glow red, add the new load of wood in the firebox.
f) Keep the door of the Elegance 42 slightly unlatched until you see a flame in the firebox. Never leave
the Elegance 42 door unlatched without constant supervision.
g) Completely latch the Elegance 42 door and turn the blower back on.
Assure that a flame is maintained. Avoid wood smoldering on top of embers as this will result in a dirty glass,
excessive emissions, chimney creosote buildup and poor heat output. If wood is smoldering, ensure the
Activator has been activated and unlatch the door slightly with supervision until a flame has been maintained.
5.6 Blower Kit Operation
The blower kit for the Elegance 42 consists of two blowers mounted at the back/bottom of the unit and a heat
sensory therm-o-disc; the blowers will start and stop automatically in the presence and absence of heat
respectively. A variable speed control allows the adjustment of the speed of the blowers. Do not install a
substitute kit as this may result in overheating and risk of fire. Refer to Section 3.9 for the installation
instructions of the blower kit.
When the fireplace gets hot and the therm-o-disc reaches 95°F, the blowers will turn on. The average time it
takes for the blowers to activate is 30 to 45 minutes after starting a fire as explained in Section 5.4. The
blowers will turn off once the insert has cooled down and the therm-o-disc reaches 85°F. The speed of the
blowers can be adjusted with the variable speed control.
CAUTION: To avoid ash and dust contamination, it is recommended to clean the blower at least once a
year and to keep the hearth area clean. The blower must always be turned off before opening the door
of the fireplace to reload. Failure to do so will void the warranty of the blower.
Содержание 38SF
Страница 43: ...40 CERTIFICATION LABEL...