13
※
Opening Mode
-
Temporary Open
: When the door is open, it is automatically closed after a specific time.
-
Toggle
: The door is opened after the first authorization success and it remains unlocked
until the second authorization success.
Enter the time and press
OK
.
*The time is set for
automatically closing the
door after the specified
time
.
Use
▶
/
◀
buttons to
select
Not Use
for Held
Open Alarm and press
OK
.
*Not Use/Sound/Backlight/
Sound & Light/SIO Relay0/
SIO Relay1
Door Sensor
SIO Input 1
SIO Relay 0
Held Open Alarm
Not Use
Door
Use
▶
/
◀
buttons to
select
N.O
and press
OK
.
Use
▶
/
◀
buttons to
select
SIO Input 1
and
press
OK
.
*Not Use/ SIO Input0/ SIO
Input1
Opening Mode
Temporary Open
Door
Use
▶
/
◀
buttons to
select
Temporary Open
for opening mode and
press
OK
.
* Temporary Open/Toggle
Type
N.O
Door Sensor
Open Time(sec)
3
Door
Use
▶
/
◀
buttons to
select
Not Use
for Forced
Open Alarm and press
OK
.
*Not Use/Sound/Backlight/
Sound & Light/SIO Relay0/
SIO Relay1
The completion message
window appears
.
Forced Open Alarm
Not Use
Door
Complete
When you exit from the menu before completing the relay setup, the
configuration is not stored so please finish configuration until the
message “Complete” appears.
Sync button (In case of using Secure I/O)
Synchronization between Secure I/O and BioLite
Solo is to enhance security by exchanging an
encrypted key, which prevents the operation of
Secure I/O when the external device has been
exchanged by an intruder. Sync button should be
pressed when Relay setting is completed.