background image

 

 

PREFACE 

INTRODUCTION:

 

      Combined  Table  CS-700  is  a  precise  instrument  which  can  be  used  with  Refractometer,  Slit  Lamp,  Vi
ew  Tester,  Chart  Projector  etc.  It  makes  the  operation  of  other  instruments  convenient  and  precise.  Luxur
ious  leather  chair  is  quite  quiet  when  operating.  Luxurious  swing  arm  can  move  freely,  can  the  work  tab
le  can  circumrotate  for  90  degree.  This  can  save  a  lot  of  installation  space.  The  tray  can  be  moved 

with

a  refractometer  mobile  tray,  the  CD  drawer  to  put  the  refractometer  tray. 

 

SAFETY INFORMATION 

 

1.Safety  symbols  and  instructions 

The  arrow  direction  and  the  table  in  the  same  direction 

2.Using  environment  and  notes   
1)    Read  and  understand  all  instructions. 
2)  Using  under  the  operation  and  the  warning  on  the  main  machine. 
3)  Please  do  not  near  the  water  using  the  instrument,  do  not  use  or  place  the  instrument  in  damp  places 
4)  Please  place  the  instrument  smooth  on  solid  ground.  Otherwise,  the  machine  falls  can  lead  serious  da
mage  or  injuries. 
5)  When  installing  a  good  instrument,  please  check  up  the  installed  correctly,  and  access  to  the  total  po
wer  supply,  when  stop  using  for  a  long  time,  should  cut  off  power  supply. 
6)  When  cleaning  the  instrument,  please  pull  out  the  machine  power  plug,  make  sure  to  cut  off  all  the 
power.  Please  use  the  wet  cloth  to  wipe,  power  can  be  supplied  after  all  dry.  (Cleaning  inside  after  tear 
down  the  machine  is  forbidden) 
7)  When  malfunction  or  abnormal  phenomenon  occurred,  please  immediately  cut  off  the  power  and  conta
ct  maintenance  personnel,  do  not  handle  by  yourself. 
8)According  to  the  product  principle,  working  mode  and  characteristics  of  this  product,  do  not  need  to  st
erilize,  and  don't  have  to  prevent  the  radiation  protection 

 

 

 

 

 

 

 

Содержание CS-700

Страница 1: ...Combined Table CS 700 Operation Manual REV 20160201 ...

Страница 2: ...ne 3 Please do not near the water using the instrument do not use or place the instrument in damp places 4 Please place the instrument smooth on solid ground Otherwise the machine falls can lead serious da mage or injuries 5 When installing a good instrument please check up the installed correctly and access to the total po wer supply when stop using for a long time should cut off power supply 6 W...

Страница 3: ... instruction 4 1 Installation 4 2 Adjustment 7 3 Test and use 7 3 Maintaince 8 1 Daily Maintaince 8 2 Meterial replacement 8 3 Cleaning 8 4 Moving machine notes 8 5 Service information 8 4 Simple fault phenomenon and removing 8 Fuse replacement method 8 5 Performacnce parameter 8 6 Attachment list 9 ...

Страница 4: ...3 1 Introduction 1 Main machine 2 Operation Panel parts detailed introduction On Off Chair up Chair down Test Rest Up Down ...

Страница 5: ...ng materials open the host side the fixed screw will be unloaded with a wrench See Figure 1 4 Take out the main machine from the wooden tray Figure 1 5 Put the machine on the smooth and solid ground install the pedal parts Unload four solid screw from the pedal plate See figure 2 remove cover plate and take out the holder Fix the holder and the main machine cover the plate and fix the screw in the...

Страница 6: ...flange thread hole figure 4 8 table parts installation 2 Put the mesa cable through from the flange thread hole The mesa with four screws along the direction of arrow and flange fixed tightly see figure 5 Figure5 9 table parts installation 2 See figure 6 Take out the right side The table direction should be the same as the arrow direction Lock firmly as the arrow direction Install the right plate ...

Страница 7: ...st for a easier screw installation 11 he installation of swing arm part 2 Turn off the general power connect the arm power line with the plug in and fix the arm Then put the view tester hanger arm into the swing arm firmly Figure 7 Figure 7 12 The installation of the projector base parts See figure 8 There are two holes to fix on the table by screw ...

Страница 8: ...r mats When lifting the chair up down the chair runs steadily and without nose the range is 20cm 8 Check whether the power supply for the work board and chart projector are all right or not 3 Test and use 1 Rotate the table 90 degrees anticlockwise Patient can easily sit on the chair 2 Rotate the table 90 degrees clockwise to the front of the patient to us the refractometer return t o original whe...

Страница 9: ...o other instrument on the machine Notice the power line when moving to prevent broken 5 Service information Firstly cut off the power when abnormal appear and then consult the sales department of the after sales department 4 Imple fault phenomenon and removing Fuse replacement method A Shut off the power switch pull the power cord B Use a screwdriver set aside fuse hat remove damaged fuse C Change...

Страница 10: ...9 6 Attachment list CS 700 spare parts Item Name Picture Parts Number Quantity Remar k 1 View tester arm 1 2 Projector steel plate 1 3 Swing arm plate 1 4 Projector type steel 2 5 Table parts 1 ...

Отзывы: