04-1
WINCH INSTALLATION
WINCH INSTALLATION
04
MOUNTING
Figs. 3 & 4 show the mounting dimensions for the Superwinch H10/12/14P.
Because of the rating of these winches, it is important that the mountings are secure. M12 x 1.5 pitch 8.8 Grade High
Tensile Steel bolts must be used in order to sustain the loads imposed on the winch mounting. Remember that the
winch is only as strong as it’s mountings.
All eight mount holes should be used. Use only the threaded holes provided, Do not drill and tap new hole(s). Do not
weld the winch or any parts of the winch. After mounting and tightening all mounting bolts, place the winch in freespool
and check the drum rotation. The drum on an incorrectly mounted winch may bind causing poor freespooling and
decreased winch performance. If the drum does bind loosen all mounting bolts. If the drum now rotates freely, tighten
the bolts a bit at a time, checking thee drum rotation until the winch is securely fastened. If the drum continues to bind it
is probable that one or more of the mounting system’s holes is out of position and requires correction.
Precautions for foot down mounting.
1. The plate to which the winch is fastened must be 6mm thick min. steel.
2. All four mounting holes in the bottom of each support casting must be used to mount the winch.
Precautions for rail mounting.
1. The angle iron used for the rails must be 50mm x 50mm x 6mm or larger.
2. All four mounting holes (2 in each side of the casting) must be used.
Mounting Dimensions for Winches
* Dimensions for 653001 only
Dimensions in mm.