1. Fill the grinder with the desired crop, grind and wait 1-2 minutes before pressing the ’ON/TEST’
button
2. Read the results on the result screen
Adjusting the Calibration of the Meter
Superpro is factory calibrated for every crop using the official methods of measuring moisture content as
compiled by ISTA (International Seed Testing Association). The calibration scales are compiled using
samples of crops grown in normal conditions. Differing growth factors between years and between
varieties can have an effect on the electrical characteristics of the crop and it can therefore be necessary to
recalibrate the meter. To avoid disputes, it is strongly recommended that Superpro is checked against the
meter being used by the buyer of the grain (using grain from the same sample in both cases), and adjusted
as required.
Each crop calibration in the meter can, if necessary, be adjusted individually up or down by up to 3.9% in
increments of 0.1%. This is achieved as follows:
1. Turn on the meter by pressing ON/TEST.
2
.
When MEASURE appears in the display use the arrow keys
⇑
or
⇓
until CALIBRATION is
displayed.
3. Accept this choice by pressing ON/TEST.
4
.
Use the arrow keys
⇑
or
⇓
to select the crop that is in need of calibration adjustment.
5. Accept this choice by pressing ON/TEST. The numeric value +0.0 is shown in the display (factory
calibration).
6
.
Use the arrow keys
⇑
or
⇓
until the desired calibration adjustment value is displayed.
Adjustments can be made in the range from -3.9% to +3.9%.
7. Accept the selected calibration adjustment value by pressing ON/TEST.
8. An asterisk (*) will appear at the end of the name of the crop if adjustments have been made
compared to the factory calibration.
Ver 1.1.0
GB
Page 8/13