background image

Chapter 2: Installation

2-13

Populating UDIMM (ECC/Non-ECC) Memory Modules

Intel E5-2600 Series Processor UDIMM Memory Support

Ranks Per 

DIMM & 

Data Width

Memory Capacity 

Per DIMM

(See the Note below)

Speed (MT/s) and Voltage Validated by Slot per Channel 

(SPC) and DIMM Per Channel (DPC)

1 Slot Per Channel

2 Slots Per Channel

1DPC

1DPC

2DPC

1.35V

1.5V

1.35V

1.5V

1.35V

1.5V

SRx8 

Non-ECC

1GB

2GB

4GB

NA

1066, 1333, 

1600

NA

1066, 

1333

NA

1066,

1333

DRx8 

Non-ECC

2GB

4GB

8GB

NA

1066, 1333, 

1600

NA

1066, 

1333

NA

1066,

1333

SRx16 

Non-ECC

512MB

1GB

2GB

NA

1066, 1333, 

1600

NA

1066, 

1333

NA

1066,

1333

SRx8 ECC

1GB

2GB

4GB

1066, 

1333

1066, 1333, 

1600

1066, 

1333

1066, 

1333

1066

1066,

1333

DRx8 ECC

2GB

4GB

8GB

1066, 

1333

1066, 1333, 

1600

1066, 

1333

1066, 

1333

1066

1066,

1333

Note:

 For detailed information on memory support and updates, please refer to the SMC Recommended    

Memory List posted on our website at http://www.supermicro.com/support/resources/mem.cfm.

Populating RDIMM (ECC) Memory Modules

Intel E5-2600 Series Processor RDIMM Memory Support

Ranks 

Per 

DIMM 

& Data 

Width

Memory Capacity 

Per DIMM

(See the Note Below)

Speed (MT/s) and Voltage Validated by Slot per Channel (SPC) and 

DIMM Per Channel (DPC)

1 Slot Per Channel

2 Slots Per Channel

1DPC

1DPC

2DPC

1.35V

1.5V

1.35V

1.5V

1.35V

1.5V

SRx8 

1GB

2GB

4GB

1066, 

1333

1066, 1333, 

1600

1066, 

1333

1066, 1333, 

1600

1066, 

1333

1066, 1333, 

1600

DRx8 

2GB

4GB

8GB

1066, 

1333

1066, 1333, 

1600

1066, 

1333

1066, 1333, 

1600

1066, 

1333

1066, 1333, 

1600

SRx4 

2GB

4GB

8GB

1066, 

1333

1066, 1333, 

1600

1066, 

1333

1066, 1333, 

1600

1066, 

1333

1066, 1333, 

1600

DRx4

4GB

8GB

16GB

1066, 

1333

1066, 1333, 

1600

1066, 

1333

1066, 1333, 

1600

1066, 

1333

1066, 1333, 

1600

QRx4

8GB

16GB

32GB

800

1066 

800

1066 

800

800

QRx8

4GB

8GB

16GB

800

1066

800

1066

800

800

Note:

 For detailed information on memory support and updates, please refer to the SMC Recommended    

Memory List posted on our website at http://www.supermicro.com/support/resources/mem.cfm.

Содержание X9DRG-HF+

Страница 1: ...USER S MANUAL Revision 1 0a X9DRG HF X9DRG HTF...

Страница 2: ...H DAMAGES IN PARTICULAR SUPER MICRO COMPUTER INC SHALL NOT HAVE LIABILITY FOR ANY HARDWARE SOFTWARE OR DATA STORED OR USED WITH THE PRODUCT INCLUDING THE COSTS OF REPAIRING REPLACING INTEGRATING INSTA...

Страница 3: ...R3 memory This motherboard is ideal for GPU Graphics Processing Unit server platforms Please refer to our Website http www supermicro com for CPU and memory support updates Manual Organization Chapter...

Страница 4: ...vent damage to the system or injury to yourself Warning Important information given to ensure proper system installation or to prevent damage to the components Note Additional information given to dif...

Страница 5: ...Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Su...

Страница 6: ...allation 2 5 Installing the LGA2011 Processor 2 5 Installing a Passive CPU Heatsink 2 9 Removing the Heatsink 2 10 2 4 Installing and Removing the Memory Modules 2 11 Installing Removing DIMMs 2 11 Re...

Страница 7: ...eat LED Fan Fail 2 29 T SGPIO1 2 S Headers 2 30 SMBus Headers 2 30 Speaker Header 2 31 DOM Power Connector 2 31 2 8 Jumper Settings 2 32 Explanation of Jumpers 2 32 GLAN Enable Disable 2 32 CMOS Clear...

Страница 8: ...ice 3 8 Chapter 4 BIOS 4 1 Introduction 4 1 4 2 Main Setup 4 2 4 3 Advanced Setup Configurations 4 4 4 4 Event Logs 4 25 4 5 IPMI 4 27 4 6 Boot 4 29 4 7 Security 4 30 4 8 Save Exit 4 31 Appendix A BIO...

Страница 9: ...part of an integrated system platform Note For your system to work properly please follow the links below to download all necessary drivers utilities and the user s manual for your motherboard SMCI pr...

Страница 10: ...therboard Image Note All graphics shown in this manual were based upon the latest PCB Revision available at the time of publishing of the manual The motherboard you ve received may or may not look exa...

Страница 11: ...1 FAND FANC FANB FANA FAN4 FAN3 FAN2 FAN1 FANH FANG FANF FANE JF1 JPW2 JTPM1 JITP0 SXB1B PCI E 3 0 X16 SXB4 PCI E 3 0 X16 CPU2 SXB3 PCI E 3 0 X16 SXB2 PCI E 3 0 X16 SXB1C P1 DIMMA1 P1 DIMMA2 P1 DIMMB1...

Страница 12: ...Quick Reference T SGPIO1T SGPIO2 I SATA0 COM1 JSD1 LE4 SW1 JPW10 LAN2 LAN1 JL1 JOH1 JSPK1 JPLD1 JI2C2 JI2C1 JPW7 JPW4 JPW3 JVGA1 JPW9 JPW1 Battery LE1 DM1 JWD1 J30 JPB1 J29 JPL1 JPG1 FAND FANC FANB F...

Страница 13: ...ntrusion JOH1 Overheat LED Indicator JI2 C1 JI2 C2 SMBbus I2 C Headers for SXB5 PCI E Slot JPW1 SMC Proprietary 62 pin PWR Connector Warning Next Page JPW2 SMC Proprietary 20 pin PWR Connector Warning...

Страница 14: ...ers 0 1 for I SATA Ports 0 5 USB 0 1 Back Panel USB 0 1 X9DRG HF X9DRG HTF LED Indicators LED Description State Status DM1 BMC Heartbeat LED Green BMC Normal LE1 Standby PWR LED Green On SB Power On L...

Страница 15: ...s motherboard Chipset Intel C602J PCH Expansion Two 2 PCI E 3 0 x16 slots for GPU use SXB3 SXB4 Two 2 PCI E 3 0 x16 slots SXB1A 1B 1C SXB2 One 1 PCI E 3 0 x8 in x16 slot SXB5 Slots Graphics Nuvoton BM...

Страница 16: ...1 below CPU 5 1 Phase switching voltage regulator CPU System overheat LED and control CPU Thermal Trip support Thermal Monitor 2 TM2 support Fan Control Fan status monitoring with firmware thermal man...

Страница 17: ...TA USB 2 0 USB 2 Rear 3 0 Gb S 6 0 Gb S I SATA PORTs 2 5 DDRIII P1 P1 P0 P0 E 1 D 2 D 1 C 2 C 1 B 2 B 1 A 2 A 1 QPI 8G SXB 1 SXB 5 E5 2600 Series CPU1 CPU2 PCH C602 PCI E X16 Gen3 DMI2 SPI Dedicated L...

Страница 18: ...to point serial interconnect interface with a transfer speed of up to 8 0 GT s providing superb system performance The PCH chipset provides extensive IO support including the following functions and c...

Страница 19: ...ltages Once a voltage becomes unstable a warning is given or an error message is sent to the screen The user can adjust the voltage thresholds to define the sensitivity of the voltage monitor Fan Stat...

Страница 20: ...terface for configuration control ACPI leverages the Plug and Play BIOS data structures while providing a processor architecture independent imple mentation that is compatible with Windows 7 Windows V...

Страница 21: ...PMBus 1 1 or 1 2 Install the NMView software in your system NMView is optional and can be purchased from Supermicro Intel Intelligent Power Node Manager NM The Intel Intelligent Power Node Manager IPN...

Страница 22: ...Control Interface buses and General Purpose I O ports WPCM450R DDR2 Memory Interface The WPCM450R supports a 16 bit DDR2 memory module with a speed of up to 220 MHz For best signal integrity the WPCM...

Страница 23: ...console redirection Supports the following Management tools IPMIView CLI Command Line Interface RMCP protocol supported Note 1 For more information on IPMI configuration please refer to the IPMI User...

Страница 24: ...1 16 X9DRG HF X9DRG HTF Motherboard User s Manual Notes...

Страница 25: ...the battery is replaced incor rectly Replace the battery only with the same or equivalent type recom mended by the manufacturer Dispose of used batteries according to the manufacturer s instructions...

Страница 26: ...quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Waarschuwing Er is ontploffingsgevaar indien de batterij verkeerd vervangen wordt Vervang de b...

Страница 27: ...ming met alle nationale wetten en reglementen Attention La mise au rebut ou le recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous...

Страница 28: ...he board from the antistatic bag Handle the board by its edges only do not touch its components peripheral chips memory modules or gold contacts When handling chips or modules avoid touching their pin...

Страница 29: ...you use an Intel certified multi directional heatsink only Make sure to install the system board into the chassis before you install the CPU heatsink When receiving a server board without a processor...

Страница 30: ...late that covers the CPU socket from its locking position 3 With the lever labeled Close 1st l fully retracted gently push down on the lever labeled Open 1st to open the load plate Lift the load plate...

Страница 31: ...ce it as it may damage your CPU Instead open the load plate again and double check that the CPU is aligned properly WARNING 2 Use your thumb and index finger to hold the CPU on its edges Align the CPU...

Страница 32: ...OPEN1st OPEN1st Lever Lock Lever Lock Push down and lock the lever labeled Open 1st Push down and lock the lever labeled Close 1st Gently close the load plate 1 2 3 4 5 Close the load plate with the C...

Страница 33: ...ce the heatsink on top of the CPU so that the two mounting holes on the heatsink are aligned with those on the retention mechanism 3 Insert two push pins on the sides of the heatsink through the mount...

Страница 34: ...the motherboard in the sequence as shown in the illustration below 2 Gently wriggle the heatsink to loosen it from the CPU Do not use excessive force when wriggling the heatsink 3 Once the CPU is loo...

Страница 35: ...commended memory modules CAUTION Exercise extreme care when installing or removing DIMM modules to prevent any possible damage Installing Removing DIMMs 1 Insert the desired number of DIMMs into the m...

Страница 36: ...Performance Number of CPUs DIMMs CPU and Memory Population Configuration Table For memory to work properly please follow the instructions below 1 CPU 2 DIMMs CPU1 P1 DIMMA1 P1 DIMMB1 1 CPU 4 DIMMs CPU...

Страница 37: ...posted on our website at http www supermicro com support resources mem cfm Populating RDIMM ECC Memory Modules Intel E5 2600 Series Processor RDIMM Memory Support Ranks Per DIMM Data Width Memory Capa...

Страница 38: ...1066 1333 1066 1066 1333 Note For detailed information on memory support and updates please refer to the SMC Recommended Memory List posted on our website at http www supermicro com support resources...

Страница 39: ...dard mounting holes to fit different types of chassis Make sure that the locations of all the mounting holes for both motherboard and chassis match Although a chassis may have both plastic and metal m...

Страница 40: ...in the chassis as needed 5 Install the motherboard into the chassis carefully to avoid damaging mother board components 6 Using the Phillips screwdriver insert a Pan head 6 screw into a mounting hole...

Страница 41: ...P2 DIMMF1 P2 DIMME2 P2 DIMME1 CPU1 IPMI LAN SXB5 PCI E 3 0 x8 in x16 SXB1A JPW6 JPW5 I SATA1 I SATA2 I SATA3 I SATA4 I SATA5 JBT1 BIOS PCH C602J LAN CTRL BMC X9DRG HF Rev 1 01 CLOSE 1st OPEN 1st CLOS...

Страница 42: ...T SGPIO2 I SATA0 COM1 JSD1 LE4 SW1 JPW10 LAN2 LAN1 JL1 JOH1 JSPK1 JPLD1 JI2C2 JI2C1 JPW7 JPW4 JPW3 JVGA1 JPW9 JPW1 Battery LE1 DM1 JWD1 J30 JPB1 J29 JPL1 JPG1 FAND FANC FANB FANA FAN4 FAN3 FAN2 FAN1...

Страница 43: ...1 2 3 T SGPIO1 T SGPIO2 I SATA0 COM1 JSD1 LE4 SW1 JPW10 LAN2 LAN1 JL1 JOH1 JSPK1 JPLD1 JI2C2 JI2C1 JPW7 JPW4 JPW3 JVGA1 JPW9 JPW1 Battery LE1 DM1 JWD1 J30 JPB1 J29 JPL1 JPG1 FAND FANC FANB FANA FAN4 F...

Страница 44: ...ED HDD LED FP PWRLED Reset PWR 3 3 V ID_UID_SW 3 3V Stby Red Blue LED Cathode Ground Ground 19 20 3 3V X Ground NMI X NIC2 Link LED NIC2 Activity LED NIC1 Activity LED Unit Identifier Switch A Unit Id...

Страница 45: ...and LED indicators Refer to the following section for descriptions and pin definitions JF1 Header Pins T SGPIO1 T SGPIO2 I SATA0 COM1 JSD1 LE4 SW1 JPW10 LAN2 LAN1 JL1 JOH1 JSPK1 JPLD1 JI2C2 JI2C1 JPW7...

Страница 46: ...ATA4 I SATA5 JBT1 BIOS PCH C602J LAN CTRL BMC X9DRG HF Rev 1 01 CLOSE 1st OPEN 1st CLOSE 1st OPEN 1st USB0 1 JPME2 JPME1 Power Button Blue OH Fan Fail PWR FaiL UID LED 1 NIC1 Link LED Reset Button 2 P...

Страница 47: ...use UID switch connection The front UID switch works in conjunction with UID LED located at Pins 7 8 Also refer to Page 2 20 for more UID switch LED information See the table on the right for pin def...

Страница 48: ...WR 3 3 V ID_UID_SW 3 3V Stby Red Blue LED Cathode Ground Ground 19 20 3 3V X Ground NMI X NIC2 Link LED NIC2 Activity LED NIC1 Activity LED Power Fail LED The Power Fail LED connection is lo cated on...

Страница 49: ...ion is located on pins 1 and 2 of JF1 Momentarily contacting both pins will power on off the system This button can also be con figured to function as a suspend button with a setting in the BIOS See C...

Страница 50: ...bove to your power supply For proper system operation 2 7 Connecting Cables A JPW1 62 pin SMC Proprietary PWR Req d B JPW2 20 pin SMC Proprietary PWR Req d C JPW9 38 pin SMC Proprietary PWR Req d D JP...

Страница 51: ...CLOSE 1st OPEN 1st USB0 1 JPME2 JPME1 Chassis Intrusion A Chassis Intrusion header is located at JL1 on the motherboard Attach an appropriate cable from the chassis to inform you of a chassis intrusio...

Страница 52: ...IMMB1 P1 DIMMB2 P2 DIMMG1 P2 DIMMG2 P2 DIMMH1 P2 DIMMH2 P1 DIMMD2 P1 DIMMD1 P1 DIMMC2 P1 DIMMC1 P2 DIMMF2 P2 DIMMF1 P2 DIMME2 P2 DIMME1 CPU1 IPMI LAN SXB5 PCI E 3 0 x8 in x16 SXB1A JPW6 JPW5 I SATA1 I...

Страница 53: ...JPME2 JPME1 A TPM Port 80 Header B JOH1 TPM Header Port 80 Trusted Platform Module Port 80 header located at JTPM1 provides TPM support and Port 80 connection Use this header to enhance system perform...

Страница 54: ...I SATA1 I SATA2 I SATA3 I SATA4 I SATA5 JBT1 BIOS PCH C602J LAN CTRL BMC X9DRG HF Rev 1 01 CLOSE 1st OPEN 1st CLOSE 1st OPEN 1st USB0 1 JPME2 JPME1 K L A T SGPIO1 B T SGPIO2 C JI2 C1 D JI2 C2 T SGPIO...

Страница 55: ...0 X16 SXB4 PCI E 3 0 X16 CPU2 SXB3 PCI E 3 0 X16 SXB2 PCI E 3 0 X16 SXB1C P1 DIMMA1 P1 DIMMA2 P1 DIMMB1 P1 DIMMB2 P2 DIMMG1 P2 DIMMG2 P2 DIMMH1 P2 DIMMH2 P1 DIMMD2 P1 DIMMD1 P1 DIMMC2 P1 DIMMC1 P2 DIM...

Страница 56: ...1 01 CLOSE 1st OPEN 1st CLOSE 1st OPEN 1st USB0 1 JPME2 JPME1 K L 2 8 Jumper Settings Explanation of Jumpers To modify the operation of the mother board jumpers can be used to choose between optional...

Страница 57: ...ntact pads to prevent accidental clearing of CMOS To clear CMOS use a metal object such as a small screwdriver to touch both pads at the same time to short the connection Always remove the AC power co...

Страница 58: ...5 PCI E 3 0 x8 in x16 SXB1A JPW6 JPW5 I SATA1 I SATA2 I SATA3 I SATA4 I SATA5 JBT1 BIOS PCH C602J LAN CTRL BMC X9DRG HF Rev 1 01 CLOSE 1st OPEN 1st CLOSE 1st OPEN 1st USB0 1 JPME2 JPME1 A VGA Enabled...

Страница 59: ...m setting modifications See the table on the right for jumper settings ME Mode Select Jumper Settings Jumper Setting Definition 1 2 Normal Default 2 3 Manufacture Mode A JPME1 B JPME2 T SGPIO1T SGPIO2...

Страница 60: ...mation Activity LED 10G_ T LAN Link X9DRG HTF LED Settings Left LED Color Definition Off No Connection 10 Mbps or 100 Mbps Amber 1 Gbps Green 10 Gbps Link LED GLAN 10G LAN TLAN Activity LED Settings R...

Страница 61: ...IOS PCH C602J LAN CTRL BMC X9DRG HF Rev 1 01 CLOSE 1st OPEN 1st CLOSE 1st OPEN 1st USB0 1 JPME2 JPME1 Onboard Power LED An Onboard Power LED is located at LE1 on the motherboard When this LED is on th...

Страница 62: ...1 DIMMB1 P1 DIMMB2 P2 DIMMG1 P2 DIMMG2 P2 DIMMH1 P2 DIMMH2 P1 DIMMD2 P1 DIMMD1 P1 DIMMC2 P1 DIMMC1 P2 DIMMF2 P2 DIMMF1 P2 DIMME2 P2 DIMME1 CPU1 IPMI LAN SXB5 PCI E 3 0 x8 in x16 SXB1A JPW6 JPW5 I SATA...

Страница 63: ...JPW5 I SATA1 I SATA2 I SATA3 I SATA4 I SATA5 JBT1 BIOS PCH C602J LAN CTRL BMC X9DRG HF Rev 1 01 CLOSE 1st OPEN 1st CLOSE 1st OPEN 1st USB0 1 JPME2 JPME1 Notes For more information on SATA HostRAID con...

Страница 64: ...2 40 X9DRG HF X9DRG HTF Motherboard User s Manual Notes...

Страница 65: ...otherboard and chassis 2 Disconnect all ribbon wire cables from the motherboard including those for the keyboard and mouse 3 Remove all add on cards 4 Install CPU 1 first making sure it is fully seate...

Страница 66: ...y unplugging the power cord and contacting both pads on the CMOS Clear Jumper JBT1 Refer to Section 2 8 in Chapter 2 2 Remove all components from the motherboard especially the DIMM mod ules Make sure...

Страница 67: ...modules or slots by swapping a single module among all memory slots and check the results 6 Make sure that all memory modules are fully seated in their slots Follow the instructions given in Section 2...

Страница 68: ...g properly including boot devices such as CD DVD disc CD DVD ROM 2 Cable connection Check to make sure that all cables are connected and working properly 3 Using minimum configuration for troubleshoot...

Страница 69: ...s chapter or see the FAQs on our website http www supermicro com before contacting Technical Support 2 BIOS upgrades can be downloaded from our website http www supermicro com 3 If you still cannot re...

Страница 70: ...ps 1 2 above and continue below 2 Identify the battery s polarity The positive side should be facing up 3 Insert the battery into the battery holder and push it down until you hear a click to ensure t...

Страница 71: ...ur BIOS before downloading You can choose from the zip file and the exe file If you choose the zip BIOS file please unzip the BIOS file onto a bootable USB device Run the batch file using the format A...

Страница 72: ...e prominently displayed on the outside of the shipping carton and the shipping package is mailed prepaid or hand carried Shipping and handling charges will be applied for all orders that must be maile...

Страница 73: ...eft frame displays all the options that can be configured Grayed out options cannot be configured Options in blue can be configured by the user The right frame displays the key legend Above the key le...

Страница 74: ...can access the other setup screens An AMI BIOS identification string is displayed at the left bottom corner of the screen below the copyright message Warning Do not upgrade the BIOS unless your syste...

Страница 75: ...item displays the system time in HH MM SS format e g 15 32 52 Supermicro X9DRG HTF Version This item displays the SMC version of the BIOS ROM used in this system Build Date This item displays the dat...

Страница 76: ...instead of the normal POST messages The options are Enabled and Disabled AddOn ROM Display Mode Use this item to set the display mode for the Option ROM Select Keep Current to use the current AddOn RO...

Страница 77: ...tem to automatically reboot when a non recoverable error occurs that lasts for more than five minutes The options are Enabled and Disabled Power Button Function If this feature is set to Instant Off t...

Страница 78: ...chnology Intel VT x Technology Intel SMX Technology L1 Data Cache L1 Code Cache L2 Cache L3 Cache CPU Speed This item displays the speed of the CPU installed in the Socket selected 64 bit This item in...

Страница 79: ...cannot thus preventing a worm or a virus from flooding illegal codes to overwhelm the processor or damage the system during an attack The default is Enabled Refer to Intel and Microsoft Web sites for...

Страница 80: ...u allows the user to configure the following CPU Power Management settings Power Technology Select Energy Efficiency to support power saving mode Select Custom to cus tomize system power settings Sele...

Страница 81: ...ate limit Available when Power Technology is set to Custom This feature allows the user to set the limit on the C State package register The options are C0 C2 C6 and No Limit Energy Performance Bias U...

Страница 82: ...ogy support for Direct I O VT d by reporting the I O device assignments to the VMM Virtual Machine Monitor through the DMAR ACPI Tables This feature offers fully protected I O resource sharing across...

Страница 83: ...N2 and GEN3 CPU2 IIO 2 PCIe Port Bifurcation Control This submenu configures the following IO PCIe Port Bifurcation Control settings for the PCIe ports to determine how the available PCI Express lanes...

Страница 84: ...duplicate copy of the data stored in the memory to enhance data security Sparing This item displays if memory sparing is supported by the motherboard Memory sparing enhances system performance DIMM I...

Страница 85: ...aused by internal processing By using this method roughly 64 GB of memory behind the IO hub will be scrubbed every day The options are Enabled and Disabled Demand Scrub Demand Scrubbing is a process t...

Страница 86: ...Enabled to support legacy USB devices Select Auto to disable legacy sup port if USB devices are not present Select Disabled to have USB devices available for EFI Extensive Firmware Interface applicati...

Страница 87: ...controller manages the power usage of the SATA link The controller will put the link in a low power mode during extended periods of I O inactivity and will return the link to an active state when I O...

Страница 88: ...d SERR Generation Select Enabled to allow a PCI device to generate an SERR number for a PCI Bus Signal Error Event The options are Enabled and Disabled Maximum Payload Select Auto to allow the system...

Страница 89: ...bled to enable the onboard LAN1 LAN2 Option ROM This is to boot the computer using a network device The default setting for LAN1 Option ROM is Enabled and the default setting for LAN2 Option ROM is Di...

Страница 90: ...3F8h IRQ 4 IO 3F8h IRQ 3 IO 2F8h IRQ 3 IO 3E8h IRQ 5 IO 2E8h IRQ 7 IO 3F8h IRQ 3 4 5 6 7 10 11 12 IO 2F8h IRQ 3 4 5 6 7 10 11 12 IO 3E8h IRQ 3 4 5 6 7 10 11 12 IO 2E8h IRQ 3 4 5 6 7 10 11 12 Device M...

Страница 91: ...lt setting for COM1 is Disabled and for COM2 is Enabled Console Redirection Settings This feature allows the user to specify how the host computer will exchange data with the client computer which is...

Страница 92: ...erial data communication Select 2 Stop Bits if slower devices are used The options are 1 and 2 Flow Control This feature allows the user to set the flow control for Console Redirection to prevent data...

Страница 93: ...ole Redirection Settings for EMS This feature allows the user to specify how the host computer will exchange data with the client computer which is the remote computer used by the user Out of Band Man...

Страница 94: ...aches and stop executing instructions Power to the CPU s and RAM is maintained but RAM is refreshed Select Sus pend Disabled to use power reduced mode Power will only be supplied to limited components...

Страница 95: ...this item to schedule an operation for the security device The options are None Enable Take Ownership Disable Take Ownership and TPM Clear Note During restart the computer will reboot in order to exec...

Страница 96: ...ndicates if the Intel TXT support is enabled or disabled The default setting is Disabled Note Be sure to format your TPM module before enabling TXT LT SX support for this feature to work properly Inte...

Страница 97: ...nagement BIOS Event Logging during system boot The options are Enabled and Disabled Runtime Error Logging Support Select Enabled to support Runtime Error Logging The options are Enabled and Disabled M...

Страница 98: ...ons are Do Nothing and Erase Immediately SMBIOS Event Log Standard Settings Log System Boot Event Select Enabled to log system boot events The options are Disabled and Enabled MECI Multiple Event Coun...

Страница 99: ...ed in your system System Event Log Enabling Disabling Options SEL Components Select Enabled for all system event logging at bootup The options are Enabled and Disabled Erasing Settings Erase SEL Selec...

Страница 100: ...e effect when the system is rebooted The options are No and Yes Configuration Address Source This feature allows the user to select the source of the IP address for this computer If Static is selected...

Страница 101: ...iority Boot Option 1 Boot Option 2 etc Use these items to specify the sequence of boot device priority Network Devices USB Device BBS Priorities Hard Disk Drives The above options appear when detected...

Страница 102: ...password entry is required Select Setup to require the password only when entering setup Select Always to require the pass word when entering setup and on each boot The options are Setup and Always A...

Страница 103: ...d Reset When you have completed the system configuration changes select this option to save the changes and reboot the computer so that the new system configuration settings can take effect Select Sav...

Страница 104: ...ults Select this feature and press Enter to save the current settings as the user s defaults When the dialog box appears asking you if you want to save values as user s defaults click Yes to save the...

Страница 105: ...s These fatal errors are usually communicated through a series of audible beeps The numbers on the fatal error list correspond to the number of beeps for the corresponding error A 1 BIOS Error Beep Co...

Страница 106: ...A 2 X9DRG HF X9DRG HTF Motherboard User s Manual Notes...

Страница 107: ...storage driver diskette by booting into a Driver CD please set the SATA Configuration to Compatible Mode and configure SATA as IDE in the BIOS Setup After making the driver diskette be sure to change...

Страница 108: ...Doctor III displays crucial system information such as CPU temperature system voltages and fan status See the Figure below for a display of the SuperDoctor III interface Note 1 The default user name a...

Страница 109: ...III Interface Display Screen II Remote Control Note The SDIII utility and the user guide can be downloaded from our website at http www supermicro com products accessories software SuperDoctorIII cfm...

Страница 110: ...B 4 X9DRG HF X9DRG HTF Motherboard User s Manual Notes...

Страница 111: ...expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro disclaims any and all liability and should buyer use or sell such products for use in su...

Отзывы: