Chapter 4: AMI BIOS
4-21
SEL Record Type
•
Timestamp
•
Generator ID
•
Event Message Format User
•
Event Sensor Type
•
Event Sensor Number,
•
Event Dir Type
•
Event Data.
•
Clear BMC System Event Log
Clear BMC System Log
Select OK and press the <Enter> key to clear the BMC system log. Select Cancel
to keep the BMC System log. The options are
OK
and Cancel.
Caution
: Any cleared information is unrecoverable. Make absolutely sure
that you no longer need any data stored in the log before clearing the
BMC Event Log.
Set LAN Confi guration
Set this feature to confi gure the IPMI LAN adapter with a network address as shown
in the following graphics.
Channel Number
- Enter the channel number for the SET LAN Confi g com-
mand. This is initially set to
[1]
. Press "+" or "-" on your keyboard to change
the Channel Number.
Channel Number Status
- This feature returns the channel status for the
Channel Number selected above: "Channel Number is OK" or "Wrong Channel
Number".
IP Address Confi guration
Enter the IP address for this machine. This should be in decimal and in dotted
quad form (e.g., 192.168.10.253). The value of each three-digit number sepa-
rated by dots should not exceed 255 as shown in the screen below.