Содержание SuperServer 6113M-i

Страница 1: ...SUPERSERVER 6113M i USER SMANUAL 1 0 SUPER...

Страница 2: ...R INABILITY TO USE THIS PRODUCT OR DOCUMENTATION EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES IN PARTICULAR THE VENDOR SHALL NOT HAVE LIABILITY FOR ANY HARDWARE SOFTWARE OR DATA STORED OR USED W...

Страница 3: ...verboard and the SC813Hi 500 chassis Chapter 2 Server Installation This chapter describes the steps necessary to install the SuperServer 6113M i into a rack and check out the server configuration prio...

Страница 4: ...r detailed information on the 1U SC813Hi 500 rackmount server chassis You should follow the procedures given in this chapter when installing removing or reconfiguring IDE or peripheral drives and when...

Страница 5: ...v Preface Notes...

Страница 6: ...aring for Setup 2 1 Choosing a Setup Location 2 2 Rack Precautions 2 2 Server Precautions 2 2 2 4 Installing the Server into a Rack 2 3 Identifying the Sections of the Rack Rails 2 3 Installing the In...

Страница 7: ...5 11 5 4 I O Ports 5 12 5 5 Installing Memory 5 12 5 6 Adding PCI Cards 5 14 5 7 Serverboard Details 5 15 i2DMR iG2 Layout 5 15 i2DMR iG2 Quick Reference 5 16 5 8 Connector Definitions 5 17 EPS 12V P...

Страница 8: ...s 5 26 Chapter 6 Advanced Chassis Setup 6 1 Static Sensitive Devices 6 1 6 2 Control Panel 6 2 6 3 System Fans 6 3 System Fan Failure 6 3 Replacing System Fans 6 3 6 4 Drive Bay Installation Removal 6...

Страница 9: ...ix Appendices Appendix A BIOS Error Beep Codes and Common Debug Codes A 1 Appendix B BIOS POST Checkpoint Codes B 1 Appendix C Software Drivers and Operating System Installation C 1 Appendix D System...

Страница 10: ...SUPERSERVER 6113M i User s Manual x Notes...

Страница 11: ...inboard and chassis various hardware components may have been included with your SuperServer 6113M i as listed below Up to two 2 Intel Itanium2 CPUs of up to 1 50 GHz with 6 MB L3 cache optional Up to...

Страница 12: ...y bandwidth of 6 4 GB s Each DDR Memory Hub connects to two branch channels and supports up to four DDR SDRAM DIMMs per channel The Scalability Port SP provides simultaneous bi directional signaling w...

Страница 13: ...B memory modules PCI Expansion Slots The i2DMR iG2 has one 64 bit 133 100 MHz PCI X slot A riser card is included with the server This riser card fits into the PCI X slot and was designed specially fo...

Страница 14: ...assis intrusion header auto switching voltage regulators chassis and CPU overheat sensors virus protection and BIOS rescue SNC Processor 1 Processor 2 ICH4 16 GB Max DDR200 3x1MB FWH MRH_D MRH_D DIMM1...

Страница 15: ...es a 500W cold swap power supply Control Panel The SC813Hi control panel provides important system monitoring and control information LEDs indicate power on network activity hard disk drive activity a...

Страница 16: ...um2 configurations The SC813Hi includes two heavy duty 10 cm blower fans located in the middle of the chassis These fans operate continuously at full rpm If they break down the ambient air temperature...

Страница 17: ...s SuperMicro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Techni...

Страница 18: ...SUPERSERVER 6113M i User s Manual 1 8 Notes...

Страница 19: ...it was damaged in any way If the server itself shows damage you should file a damage claim with the carrier who delivered it Decide on a suitable location for the rack unit that will hold the SuperSer...

Страница 20: ...stable before extending a component from the rack You should extend only one component at a time extending two or more simultaneously may cause the rack to become unstable Server Precautions Review t...

Страница 21: ...with the SuperServer 6113M i Each of these assemblies consists of two sections an inner fixed chassis rail that secures to the 6113M i A and an outer fixed rack rail that secures directly to the rack...

Страница 22: ...racket to the front side of the outer rail with two M4 screws and the long bracket to the rear side of the outer rail with three M4 screws Repeat these steps for the left outer rail Locking Tabs Both...

Страница 23: ...the front of the rack rails Slide the chassis rails into the rack rails keeping the pressure even on both sides you may have to depress the locking tabs when inserting See Figure 2 3 When the server...

Страница 24: ...6113M i into a Telco type rack follow the directions given on the previous pages for rack installation The only difference in the installation procedure will be the positioning of the rack brackets t...

Страница 25: ...to the inside of the server 2 Check the CPUs processors You should have one or two processors already installed into the serverboard Each processor needs its own heatsink and power pod VRM installed S...

Страница 26: ...Make sure all power and data cables are properly connected and not blocking the chassis airflow See Chapter 5 for details on cable connections Also check the air seals for damage The air seals are lo...

Страница 27: ...s configuration your system may have one or more drives already installed If you need to install IDE drives please refer to Chapter 6 4 Check the airflow Airflow is provided by two heavy duty 10 cm bl...

Страница 28: ...SUPERSERVER 6113M i User s Manual 2 10 Notes...

Страница 29: ...upply This chapter explains the meanings of all LED indicators and the appropriate response you may need to take 3 2 Control Panel Buttons There are two push button buttons located on the front of the...

Страница 30: ...irflow in the system or the ambient room temperature being too warm You should also check to make sure that the chassis cover is installed and that all fans are present and operating normally Finally...

Страница 31: ...memory modules and the CD ROM and IDE drives When disconnecting power you should first power down the system with the operating system and then unplug the power cords of all the power supply units in...

Страница 32: ...be pulled into a cooling fan Remove any jewelry or metal objects from your body which are excellent metal conductors that can create short circuits and harm you if they come into contact with printed...

Страница 33: ...use Touch a grounded metal object before removing any board from its antistatic bag Do not let components or PCBs come into contact with your clothing which may retain a charge even if you are wearing...

Страница 34: ...4 Operating Precautions Care must be taken to assure that the chassis cover is in place when the 6113M i is operating to ensure proper cooling Out of warranty damage to the 6113M i system can occur if...

Страница 35: ...that the size and weight of the serverboard can cause it to bend if handled improperly which may result in damage To prevent the serverboard from bending keep one hand under the center of the board t...

Страница 36: ...all the CPU heatsink To optimize the functionality and capability of the i2DMR iG2 we recommend it be installed in Supermicro chassis only Warning The heatsink on the MRH D chip has been pre installed...

Страница 37: ...lling the Heatsink Retention Mechanism 1 Place the retention mechanism SKT 0147 RM IT2 on the serverboard as shown in the picture below 2 Secure the retention mechanism to the serverboard by screwing...

Страница 38: ...serverboard against the corresponding mounting holes in the chassis 4 Secure the serverboard to the chassis by screwing in the six 6 32 9 mm screws into the aligned holes on the serverboard and chassi...

Страница 39: ...ngle of the CPU socket as shown in the picture below Itanium2 CPU CPU1 Socket 2 Use the M2 5 hex key to secure the Itanium2 CPU as shown in the picture below Securing CPU with M2 5 hex key Please refe...

Страница 40: ...verboard 2 Carefully push the edge connector of the power pod toward the CPU until the signal pins on both edges of the CPU are fully seated in the edge connector and you hear a click CPU power pod It...

Страница 41: ...er pod as needed Securing the power pod with four M3 screws 3 Locate four of the M3 screws in the VRM 008 package and use them to secure the power pod onto the serverboard as shown in the picture belo...

Страница 42: ...d with Itanium2 CPUs 1 Place a heatsink SNK 0046 on top of the CPU so that the four mounting holes are aligned with those on the retention mechanism as shown in Figure 1 below 2 Screw in two diagonal...

Страница 43: ...Figure 5 3 CPUs with Heatsinks Installed Connecting AC Power 1 Connect the 24 pin power connector from the AC power supply to the serverboard See the serverboard layout diagram in this chapter for th...

Страница 44: ...s If you are configuring the system keep the airflow in mind when routing the cables The following data cables with their serverboard con nector locations noted should be connected See the serverboard...

Страница 45: ...use with Supermicro server chassis All U66 wires have been bundled into single ribbon cable to simplify their connection The red wire should plug into pin 1 as marked on the serverboard The other end...

Страница 46: ...1 Insert four identical DIMMs modules of the same size and type into the DIMM1 DIMM2 DIMM3 and DIMM4 sockets J16 J13 J11 and J9 repectively These four DIMM sockets are colored blue If eight DIMMs are...

Страница 47: ...otch To Remove Use your thumbs to gently push each release tab outward to free the DIMM from the socket Memory Support The i2DMR iG2 supports up to 16 GB of buffered reistered ECC DDR200 DDR266 memory...

Страница 48: ...CI add on card see step 1 above Begin by swinging the release tab on the I O backpanel shield out to the left for the PCI slot Insert the PCI card into the correct slot on the butterfly riser card dep...

Страница 49: ...installed by the manufacturer Please do not touch it Turning the heatsink the wrong way will damage it and void the manufacturer s warranty PWR Pod Battery J20 U62 Fan3 J28 CN5 Fan1 J34 U S B 0 1 J38...

Страница 50: ...Connector J4 Back Panel Universal Serial Ports USB2 3 J5 COM1 Serial Port J6 Wake on Ring Header J9 J16 DDR Memory Sockets J19 PCI X Bus 256 Pin Slot J20 24 pin Power1 Connector J21 Front Panel USB He...

Страница 51: ...initions 12V 24 pin Power Supply Connector Pin Definitions J20 J36 Pin Number Definition 13 3 3V 14 12V 15 COM 16 PS_ON 17 COM 18 COM 19 COM 20 Res NC 21 5V 22 5V 23 5V 24 COM Pin Number Definition 1...

Страница 52: ...HDD LED Pin Definitions U66 Pin Number 13 14 Definition Vcc HD Active NIC LED Pin Definitions U66 Pin Number 11 12 Definition Vcc GND NIC2 LED The NIC Network Interface Control ler LED connection for...

Страница 53: ...l Bus USB0 1 USB2 3 Four USB 2 0 ports are located on the back panel These are desig nated J1 USB0 1 and J4 USB2 3 USB0 is the bottom connector and USB1 is the top connector of J1 USB2 is the bottom c...

Страница 54: ...nform you of a chassis in trusion See the table on the right for pin definitions Serial Ports There are two Serial Ports on the serverboard The COM1 serial port J5 is located on the back panel and the...

Страница 55: ...1 2 Definition Ground Wake up Speaker Header The speaker header is located on CN4 See the table on the right for speaker pin definitions Note The speaker connector pins are for use with an external s...

Страница 56: ...m Management Bus header is located at J22 Connect the ap propriate cable here to utilize SMB on your system Power Fault Pin Definitions U62 Pin Number 1 2 3 4 Definition P S 1 Fail Signal P S 2 Fail S...

Страница 57: ...uare solder pad on the printed circuit board See the serverboard layout page for jumper locations Note On two pin jumpers Closed means the jumper is on and Open means the jumper is off the pins Connec...

Страница 58: ...s Jumping pins 2 3 will generate a non maskable interrupt for the program that has frozen requires software implementation Watch Dog must also be enabled in BIOS Jumper Position Pins 1 2 Pins 2 3 Open...

Страница 59: ...tor 5 10 Onboard Indicators GLAN LEDs Each of the Gigabit Ethernet LAN ports located beside the COM2 port on the back panel has two LEDs The yellow LED indicates activity while the other LED may be gr...

Страница 60: ...nction 1 Reset IDE 3 Host Data 7 5 Host Data 6 7 Host Data 5 9 Host Data 4 11 Host Data 3 13 Host Data 2 15 Host Data 1 17 Host Data 0 19 GND 21 DRQ3 23 I O Write 25 I O Read 27 IOCHRDY 29 DACK3 31 IR...

Страница 61: ...ent damage to any printed circuit boards PCBs it is important to handle them very carefully The following measures are generally sufficient to protect your equip ment from ESD damage Precautions Use a...

Страница 62: ...n the serverboard to the appro priate header on the Control Panel PCB printed circuit board Make sure the red wire plugs into pin 1 on both connectors Pull all excess cabling out of the airflow path T...

Страница 63: ...ith an identical 10 cm 12 volt fan available from Supermicro p n FAN 0059 Install the new fan in its proper place in the chassis by positioning it on the two mounting posts Secure the fan to the chass...

Страница 64: ...e the bezel first unlock the front of the chassis then press the release knob see Figure 6 3 Carefully remove the bezel with both hands A filter located within the bezel can be removed for replacement...

Страница 65: ...allation section later in this chapter for instructions CD ROM Drive For installing removing a CD ROM drive you will need to gain access to the inside of the 6113M i by removing the top cover of the c...

Страница 66: ...e chassis to access the drive carriers which may then be unscrewed and taken out When installing a hard disk drive position it in the carrier with the printed circuit board side toward the carrier and...

Страница 67: ...top of the chassis to release the top cover and at the same time push the cover away from you until it stops You can then lift the top cover from the chassis to gain full access to the inside of the s...

Страница 68: ...of the chassis near the front and push the chassis top rearward about one inch To remove the failed power unit push the beige colored release tab to the right and then carefully lift the unit up about...

Страница 69: ...Chapter 6 Advanced Chassis Setup 6 9 Figure 6 4 Removing Replacing the Power Supply...

Страница 70: ...6 10 SUPERSERVER 6113M i User s Manual Notes...

Страница 71: ...message to describe the highlighted setting AMIBIOS has default text messages built in Supermicro retains the option to include omit or change any of these text messages When an option is selected in...

Страница 72: ...SP Speed BSP CPU1 ID BSP CPU2 ID BSP L1 Cache BSP L2 Cache and BSP L3 Cache System Time System Date Use this option to change the system time and date Highlight System Time or System Date using the Ar...

Страница 73: ...d setup screen The Advanced BIOS Setup screen and sub menus are listed below When you first enter the Advanced Setup screen the Setup Warning will be displayed Please follow the instructions and set t...

Страница 74: ...tions are Enabled and Disabled The default setting for Serial Port1 is Enabled When Enabled is selected for Serial Port1 the address for Serial Port1 will be automatically set to 2F8 IRQ3 The default...

Страница 75: ...formance by increasing the amount of data transferred Only 512 bytes of data can be transferred per interrupt if block mode is not used Block mode allows transfers of up to 64 KB per interrupt Select...

Страница 76: ...e 1 25 MBs data transfer rate UDMA2 Ultra DMA mode 2 33 3 MBs data transfer rate UDMA3 Ultra DMA mode 3 66 6 MBs data transfer rate or UDMA4 Ultra DMA mode 4 100 MBs data transfer rate S M A R T For H...

Страница 77: ...Device BIOS Settings Configuration This item allows the user to configure the system s boot settings Quiet Boot Set this value to allow the boot up screen options to be modified between POST messages...

Страница 78: ...r s Manual System Health Monitor This feature allows the BIOS to automatically display the status of the following items CPU Overheat Temperature CPU1 CPU2 Temperature various voltage levels and fan s...

Страница 79: ...g unexpectedly lost Options are Stay Off Power On and Last State Watch Dog Timer This setting is used to enable or disabled the Watch Dog Timer function It must be used in conjunction with the J31 jum...

Страница 80: ...is feature allows the user to configure the USB settings USB Function Select Enabled to enable the USB Host Controller The options are Disabled and Enabled Legacy USB Support Select Enabled to enable...

Страница 81: ...60 192 224 and 248 clock cycles Allocate IRQ to PCI VGA Set this value to allow or restrict the system from assigning an interrupt request address to the VGA adapter card The options are Yes and No PC...

Страница 82: ...and a User password If you use both passwords the Supervisor password must be set first Hardware Health Monitoring H W Health Function Select Enabled to enable the Hardware Health Monitoring function...

Страница 83: ...computer to allow the new system configuration parameters to take effect Exit Discarding Changes Select this option and press Enter to quit the BIOS Setup without making any permanent changes to the...

Страница 84: ...tings are designed for maximum system performance but may not work best for all computer applications Load Fail Safe Defaults To set this feature select Load Fail Safe Defaults from the Exit menu and...

Страница 85: ...ors are usually communicated through a series of audible beeps The numbers on the fatal error list on the following page correspond to the number of beeps for the corresponding error All errors listed...

Страница 86: ...Initial system memory and SIOH Off On Valid memory and SIOH found Off Off ICH4 found Common Debug Codes for IA 64 systems are listed below Checkpoints CodeDescription Note The debug code LEDs DS3 and...

Страница 87: ...zing the DMA controller performing the keyboard controller BAT test starting memory refresh and entering 4 GB flat mode next D3h Starting memory sizing next D4h Returning to real mode Executing any OE...

Страница 88: ...yte is written Next issuing the Pin 23 and 24 blocking and unblocking command 11h Next checking if End or Ins keys were pressed during power on Initializing CMOS RAM if the Initialize CMOS RAM in ever...

Страница 89: ...lay memory read write test next 32h The alternate display memory read write test passed Looking for alternate display retrace checking next 34h Video display checking is over Setting the display mode...

Страница 90: ...oft reset Displaying the first 64 KB memory size next 4Fh The memory size display has started The display is updated during the memory test Performing the sequential and random memory test next 50h Th...

Страница 91: ...as completed Checking for a locked key next 84h Locked key checking is over Checking for a memory size mismatch with CMOS RAM data next 85h The memory size check is done Displaying a soft error and ch...

Страница 92: ...ore the Coprocessor test next 9Ch Required initialization before the Coprocessor test is over Initializing the Coprocessor next 9Dh Coprocessor initialized Performing any required initialization after...

Страница 93: ...ystem data specified in the system BIOS and translates it into an object oriented language that can be easily accessed by the OS It also provides a rich environment for system pre installation EFI ini...

Страница 94: ...ash efi and bios rom 3 Connect the USB device to one of the USB ports see Chapter 5 for USB port locations 4 Bootup the system with the USB pen connected to a USB port The system will boot to the EFI...

Страница 95: ...fsX where X is the number of the sector in which your USB pen or device is located This command will change the directory from Shell to fsX 7 Now start flashing BIOS by typing fsX amiflash bios rom w...

Страница 96: ...he fsx directory appears type in the file name at the prompt fsx amiflash ami64 rom eg in the example shown above at the prompt type fs0 amiflash ami64 rom and press Enter as shown below The system wi...

Страница 97: ...ype n at the prompt if you want to keep the default values after BIOS flashing as shown in the screen above 11 When Proceed with flash update y n is displayed type y at the prompt to update the BIOS T...

Страница 98: ...accordingly 5 Enter a new description such as CD ROM 6 When prompted with Enter Boot Option Data type A Ascii U Unicode N No boot Option Then press Enter 7 When prompted with Enter Boot Option Data ty...

Страница 99: ...I Shell locate the USB device for example fsx fs0 or fs1 6 At the Shell command prompt type Shell fsX where X is the number of the file in which your USB pen or device is located This command will cha...

Страница 100: ...hell exit This command will exit the EFI Shell and return to the EFI Boot Manager 12 Select the CD ROM boot option to boot from a Windows OS installation CD after you have added the CD ROM boot option...

Страница 101: ...ting up to 16 GB of low profile registered ECC DDR200 PC1600 SDRAM Note Interleaved memory requires memory to be installed two at a time Memory speed is dependant on processor front side bus speed See...

Страница 102: ...PU2 12V3 18A for serverboard and peripherals 39A total 12V 1A 5Vsb 2A BTU Rating 2750 BTUs hr for rated output power of 500W Operating Environment Operating Temperature 0 to 35 degrees C Non operating...