2-2
S
UPER
S
ERVER 6026T-URF User's Manual
This product is for installation only in a Restricted Access Location (dedicated
•
equipment rooms, service closets and the like).
This product is not suitable for use with visual display work place devices
•
acccording to §2 of the the German Ordinance for Work with Visual Display
Units.
!
!
Warnings and Precautions!
Rack Precautions
Ensure that the leveling jacks on the bottom of the rack are fully extended to
•
the fl oor with the full weight of the rack resting on them.
In single rack installation, stabilizers should be attached to the rack. In multiple
•
rack installations, the racks should be coupled together.
Always make sure the rack is stable before extending a component from the
•
rack.
You should extend only one component at a time - extending two or more si-
•
multaneously may cause the rack to become unstable.
Server Precautions
Review the electrical and general safety precautions in Chapter 4.
•
Determine the placement of each component in the rack
•
before
you install the
rails.
Install the heaviest server components on the bottom of the rack fi rst, and then
•
work up.
Use a regulating uninterruptible power supply (UPS) to protect the server from
•
power surges, voltage spikes and to keep your system operating in case of a
power failure.
Allow any hot plug drives and power supply modules to cool before touching
•
them.
Always keep the rack's front door and all panels and components on the servers
•
closed when not servicing to maintain proper cooling.
Содержание SuperServer 6026T-URF
Страница 1: ...SUPERSERVER 6026T URF SUPER USER S MANUAL 1 0b...
Страница 5: ...Notes Preface v...
Страница 23: ...Chapter 2 Server Installation 2 9 Figure 2 3 Accessing the Inside of the System...
Страница 28: ...SUPERSERVER 6026T URF User s Manual 3 4 Notes...
Страница 58: ...5 26 SUPERSERVER 6026T URF User s Manual Notes...
Страница 92: ...A 2 SUPERSERVER 6026T URF User s Manual Notes...
Страница 97: ...C 3 Appendix C System Specifications Notes...