background image

®

S

UPER

S

ERVER

 6026T-URF

   

S

UPER

USER’S MANUAL

1.0b

Содержание SuperServer 6026T-URF

Страница 1: ...SUPERSERVER 6026T URF SUPER USER S MANUAL 1 0b...

Страница 2: ...all be the exclusive venue for the resolution of any such disputes Super Micro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has...

Страница 3: ...ard and the SC825TQ R720UB chassis Chapter 2 Server Installation This chapter describes the steps necessary to install the SuperServer 6026T URF into a rack and check out the server configuration prio...

Страница 4: ...pter 6 Advanced Chassis Setup Refer to Chapter 6 for detailed information on the SC825TQ R720UB server chassis You should follow the procedures given in this chapter when installing removing or reconf...

Страница 5: ...Notes Preface v...

Страница 6: ...2 Server Installation 2 1 Overview 2 1 2 2 Unpacking the System 2 1 2 3 Preparing for Setup 2 1 Choosing a Setup Location 2 1 Rack Precautions 2 2 Server Precautions 2 2 Rack Mounting Considerations 2...

Страница 7: ...Advanced Serverboard Setup 5 1 Handling the Serverboard 5 1 Precautions 5 1 Unpacking 5 1 5 2 Processor and Heatsink Installation 5 2 Installing LGA1366 Processors 5 2 Installing a CPU Heatsink 5 4 5...

Страница 8: ...5 Hard Drive Backplane 6 6 DVD ROM Installation 6 7 6 5 Power Supply 6 8 Power Supply Failure 6 8 Removing Replacing the Power Supply 6 8 Chapter 7 BIOS 7 1 Introduction 7 1 Starting BIOS Setup Utilit...

Страница 9: ...ve been included with the 6026T URF as listed below One slim DVD ROM drive DVM TEAC DVD SBT One SATA to USB adapter for slim DVD ROM drive CDM USATA G One internal USB cable for DVD ROM drive CBL 0341...

Страница 10: ...emory UIO The X8DTU F is a specially designed serverboard that features Supermicro s UIO Universal I O technology UIO serverboards have a PCI Express x8 slot that can support any one of several types...

Страница 11: ...e power supply module Hard Drive Subsystem The SC825TQ R720UB chassis was designed to support eight hot swap SATA or SAS hard drives Requires UIO controller card not included with system Note A SAS or...

Страница 12: ...n innovative cooling design that includes three 8 cm hot plug system cooling fans located in the middle section of the chassis An air shroud channels the airflow from the system fans to efficiently co...

Страница 13: ...MM B C E F BMC VGA ESI SATA 0 SATA SPI SST 25VF016 CLINK CLINK PCI E Ports 1 6 PCI E x8 Gen2 x16 Gen2 x8 Intel ICH10R Intel 82576 RJ45 PCI ESI Intel 5520 Port 1 PCI E x16 RJ45 SATA 1 SATA 2 SATA 3 SAT...

Страница 14: ...ress Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Te...

Страница 15: ...a suitable location for the rack unit that will hold the SuperServer 6026T URF It should be situated in a clean dust free area that is well ventilated Avoid areas where heat electrical noise and elect...

Страница 16: ...r Always make sure the rack is stable before extending a component from the rack You should extend only one component at a time extending two or more si multaneously may cause the rack to become unsta...

Страница 17: ...omised Mechanical Loading Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading Circuit Overloading Consideration should be given to the...

Страница 18: ...ures directly to the server chassis and an outer fixed rack rail that secures directly to the rack itself Installing the Inner Rail Extension The SC825 chassis includes a set of inner rails in two sec...

Страница 19: ...ner and Outer Rails Locate the rail assembly in the chassis 1 packaging Extend the rail assembly by pulling it 2 outward Press the quick release tab 3 Separate the inner rail extension from 4 the oute...

Страница 20: ...r Rails to the Rack Secure the back end of the outer rail to the rack using the screws provided 1 Press the button where the two outer rails are joined to retract the smaller 2 outer rail Hang the hoo...

Страница 21: ...e 1 Align the inner rails of the chassis with the outer rails on the rack 2 Slide the inner rails into the outer rails keeping the pressure even on both 3 sides When the chassis has been pushed comple...

Страница 22: ...ide of the server Checking the Components and Setup You may have one or two processors already installed into the serverboard 1 Each processor needs its own heat sink See Chapter 5 for instructions on...

Страница 23: ...Chapter 2 Server Installation 2 9 Figure 2 3 Accessing the Inside of the System...

Страница 24: ...Depending upon your system s configuration your system may have one or 3 more drives already installed If you need to install hard drives please refer to Chapter 6 Checking the Airflow Airflow is pro...

Страница 25: ...of specific components There are also two buttons on the chassis control panel 3 2 Control Panel Buttons There are two buttons located on the front of the chassis a reset button and a power on off bu...

Страница 26: ...ing the power supply This LED should be off when the system is operating normally Overheat Fan Fail When this LED flashes it indicates a fan failure When on continuously it indicates an overheat condi...

Страница 27: ...s on replacing failed SATA drives Red When this LED flashes it indicates the drive is rebuilding When solid on it indicates a SATA drive failure If a drive fails you should be notified by your system...

Страница 28: ...SUPERSERVER 6026T URF User s Manual 3 4 Notes...

Страница 29: ...wer you should first power down the system with the operating system first and then unplug the power cords of all the power supply units in the system When working around exposed electrical circuits a...

Страница 30: ...body which are excellent metal conductors that can create short circuits and harm you if they come into contact with printed circuit boards or areas where power is present Serverboard Battery CAUTION...

Страница 31: ...use Touch a grounded metal object before removing the board from the antistatic bag Do not let components or PCBs come into contact with your clothing which may retain a charge even if you are wearing...

Страница 32: ...tice is not strictly followed Figure 4 1 Installing the Onboard Battery LITHIUM BATTERY BATTERY HOLDER Please handle used batteries carefully Do not damage the battery in any way a damaged battery may...

Страница 33: ...hat the size and weight of the serverboard can cause it to bend if handled improperly which may result in damage To prevent the serverboard from bending keep one hand under the center of the board to...

Страница 34: ...otherwise contact your retailer immediately Refer to the Supermicro web site for updates on CPU support When handling the processor avoid placing direct pressure on the label area of the fan Also do n...

Страница 35: ...ing the CPU or the socket With the CPU in the socket in 4 spect the four corners of the CPU to make sure that it sits level and is properly installed Once the CPU is securely seated 5 in the socket lo...

Страница 36: ...amage the CPU Add the two remaining screws 5 then finish the installation by fully tightening all four screws Installing a CPU Heatsink Note see Chapter 6 for details on installing the air shroud Remo...

Страница 37: ...les connect to optional UIO SAS controller card Control Panel cable JF1 see next page Connecting Power Cables The X8DTU F has a 20 pin primary power supply connector designated JPW1 for connection to...

Страница 38: ...OH Fan Fail UID LED Power Fail LED Ground Ground 2 1 20 19 5 4 I O Ports The I O ports are color coded in conformance with the PC 99 specification See Figure 5 2 below for the colors and locations of...

Страница 39: ...emory Support The X8DTU F has 12 slots that support up to 192 GB of registered ECC DDR3 1333 1066 800 SDRAM or 24 GB of unbuffered ECC DDR3 1333 1066 800 SDRAM Notes Memory speed support depends on th...

Страница 40: ...d Speeds in MHz Ranks per DIMM any combination SR Single Rank DR Dual Rank QR Quad Rank 2 1 Reg DDR3 ECC 800 1066 1333 SR or DR 2 1 Reg DDR3 ECC 800 1066 QR 2 2 Reg DDR3 ECC 800 1066 Mixing SR DR 2 2...

Страница 41: ...the system The RSC R2UU UA3E8 riser card can support one UIO card and three full height full length PCI Express x8 expansion cards Installing a PCI Add on Card Release the locking tab that correspond...

Страница 42: ...MB JI2C1 JI2C2 JBT1 Fan5 USB2 3 JLPC1 CPU2 CPU1 Intel I5520 North Bridge Intel ICH10R South Bridge T SGPIO2 T SGPIO1 LE1 I SATA5 I SATA4 I SATA3 I SATA2 I SATA1 I SATA0 X8DTU F CPLD Fan4 Notes Jumpers...

Страница 43: ...is CPU Fan Headers IPMB IPMB I2 C Header for an IPMI Card I SATA0 I SATA5 SATA Ports JD1 Onboard Speaker Power LED JF1 Control Panel Connector JL1 Chassis Intrusion Header JOH1 Overheat Warning Header...

Страница 44: ...und 5 through 8 12V Power LED Pin Definitions JF1 Pin Definition 15 Vcc 16 Control Processor Power Connectors JPW2 and JPW3 must also be con nected to the power supply to provide power for the process...

Страница 45: ...13 and 14 of JF1 Attach the IDE hard drive LED cable to display disk activity Refer to the table on the right for pin definitions HDD LED Pin Definitions JF1 Pin Definition 13 Vcc 14 HD Active Overhe...

Страница 46: ...to the table on the right for pin definitions Universal Serial Bus Ports Two Universal Serial Bus ports are located on the I O backplane USB0 is the bottom connector and USB1 is the top connector Two...

Страница 47: ...1 COM2 Pin Definition Pin Definition 1 DCD 6 DSR 2 RXD 7 RTS 3 TXD 8 CTS 4 DTR 9 RI 5 Ground 10 NC Fan Header Pin Definitions FAN1 8 Pin Definition 1 Ground Black 2 12V Red 3 Tachometer 4 PWM Control...

Страница 48: ...eaker Connector Pin Definitions JD1 Pin Function Definition 4 Speaker data red wire 5 Key No connection 6 Key 7 Speaker data Overheat LED Connect an LED to the JOH1 header to provide warning of a chas...

Страница 49: ...indicators Push the either switch again to turn off both in dicators These UID indicators provide easy identification of a system that may be in need of service IPMB I2 C A System Management Bus head...

Страница 50: ...clear CMOS and will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS To clear CMOS First power down the system and un...

Страница 51: ...s to write their own application software to disable the Watch Dog Timer LAN Enable Disable Jumper Settings JPL1 Jumper Setting Definition Pins 1 2 Enabled Pins 2 3 Disabled Watch Dog Jumper Settings...

Страница 52: ...www supermicro com support manuals ME Mode Select Closing jumper JP3 allows the user to bypass the SPI flash security and allow the manufacturer to flash the BIOS on the production line See the table...

Страница 53: ...ystem and unplug the power cord before removing or install ing components See the tables at right for more information Onboard PWR LED Indicator LE1 LED Settings LED Color Definition Off System Off Po...

Страница 54: ...TA0 I SATA5 Pin Definition 1 Ground 2 TXP 3 TXN 4 Ground 5 RXN 6 RXP 7 Ground LE2 The LE2 LED located under SW1 is the UID indicator LED LE2 illuminates when UID is initiated either by the UID button...

Страница 55: ...ed with your serverboard Driver Tool Installation Display Screen Note Click the icons showing a hand writing on paper to view the readme files for each item Click the computer icons to the right of th...

Страница 56: ...ial system information such as CPU temperature system voltages and fan status See the Figure below for a display of the Supero Doctor III interface Note The default User Name and Password for SuperDoc...

Страница 57: ...oaded from our Web Site at ftp ftp supermicro com utility Supero_Doctor_III You can also download SDIII User s Guide at http www supermicro com PRODUCT Manuals SDIII UserGuide pdf For Linux we will st...

Страница 58: ...5 26 SUPERSERVER 6026T URF User s Manual Notes...

Страница 59: ...very carefully The following measures are generally sufficient to protect your equipment from ESD damage Precautions Use a grounded wrist strap designed to prevent static discharge Touch a grounded m...

Страница 60: ...onnect the cable from JF1 on the serverboard to the Control Panel PCB printed circuit board Make sure the red wire plugs into pin 1 on both connectors Pull all excess cabling out of the airflow path T...

Страница 61: ...ailed fan Remove the top chassis cover while the system is still running to determine which of the fans has failed Replacing System Fans Removing a Fan Remove the chassis cover 1 Press the tabs on the...

Страница 62: ...upermicro com driver SAS LSI LSI_SAS_EmbMRAID_SWUG pdf and Supermicro s web site for additional inmformation http www supermicro com support manuals DVD ROM For installing removing the DVD ROM drive y...

Страница 63: ...n with those in the carrier Secure the drive to the carrier with four screws as shown in Figure 6 3 2 Installing Removing Hot swap SAS SATA Drives Push the release button located beside the drive s LE...

Страница 64: ...Button Hard Drive Backplane The hard drives plug into a backplane that provides power drive ID and bus termi nation A RAID controller can be used with the backplane to provide data security The opera...

Страница 65: ...needed to mount a slim DVD ROM drive in the server Accessing the Inside of the Chassis Grasp the two handles on either side and pull the unit straight out until it 1 locks you will hear a click Next...

Страница 66: ...ability meaning you can replace the failed unit without powering down the system Removing Replacing the Power Supply You do not need to shut down the system to replace a power supply unit The backup p...

Страница 67: ...t be configured Options in blue can be configured by the user The right frame displays the key legend Above the key legend is an area reserved for a text message When an option is selected in the left...

Страница 68: ...s arising from a BIOS update If you have to update the BIOS do not shut down or reset the system while the BIOS is updating This is to avoid possible boot failure 7 2 Main Setup When you first enter t...

Страница 69: ...verboard Speed This item displays the speed of the CPU detected by the BIOS Physical Count This item displays the number of processors installed in your system as detected by the BIOS Logical Count Th...

Страница 70: ...ied between POST mes sages or the OEM logo Select Disabled to display the POST messages Select Enabled to display the OEM logo instead of the normal POST messages The op tions are Enabled and Disabled...

Страница 71: ...Capture Interrupt 19 is the software interrupt that handles the boot disk function When this item is set to Enabled the ROM BIOS of the host adaptors will capture Interrupt 19 at boot and allow the d...

Страница 72: ...bility Available when supported by the OS and the CPU Set to Enabled to enable the Execute Disable Bit which will allow the processor to designate areas in the system memory where an application code...

Страница 73: ...CPU will conditionally demote C6 or C7 requests to C3 based on un core auto demote information The options are Disabled and Enabled DCA Technology Select Enabled to use Intel s DCA Direct Cache Acces...

Страница 74: ...maintains two identical copies of all data in memory for redundancy Lockstep The serverboard uses two areas of memory to run the same set of operations in parallel Sparing A preset threshold of correc...

Страница 75: ...is the temperature rise to the DIMM thermal zone Each step is in 0 5o C increment The default is 020 Press or on your keyboard to change this value Air Flow This is the air flow speed to the DIMM mod...

Страница 76: ...logy significantly reduces CPU overhead by leveraging CPU architectural improvements freeing resources for more other tasks The options are Disabled and Enabled Slot SXB2 SXB3 Width This feature allow...

Страница 77: ...isabled and Enabled XIDE Floppy Configuration When this submenu is selected the AMI BIOS automatically detects the presence of the IDE or Floppy devices and displays the following items SATA 1 Configu...

Страница 78: ...BIOS to configure all devices in the system PCI Latency Timer This feature sets the latency Timer of each PCI device installed on a PCI bus Select 64 to set the PCI latency to 64 PCI clock cycles The...

Страница 79: ...Select COM to configure the onboard COM 2 port as a normal serial port Select SOL to configure the onboard COM 2 port as a virtual COM port for SOL use The options are SOL and COM Serial Port1 Address...

Страница 80: ...are ANSI VT100 and VT UTF8 VT UTF8 Combo Key Support A terminal keyboard definition that provides a way to send commands from a remote console Available options are Enabled and Disabled Sredir Memory...

Страница 81: ...actory and is the baseline on which the serverboard takes action during different CPU temperature conditions i e by increasing CPU Fan speed triggering the Overheat Alarm etc Since CPUs can have diffe...

Страница 82: ...splayed in degrees in Celsius and Fahrenheit as it is detected by the BIOS Fan 1 Fan 8 Reading This feature displays the fan speed readings from fan interfaces Fan 1 through Fan 8 Fan Speed Control Mo...

Страница 83: ...upport ACPI The op tions are Yes and No ACPI APIC Support Select Enabled to include the ACPI APIC Table Pointer in the RSDT Root System Description Table pointer list The options are Enabled and Disab...

Страница 84: ...ntry Number and pressing Enter to display the information as shown in the screen Total Number of Entries SEL Entry Number SEL Record ID SEL Record Type Event Timestamp Generator ID Event Message Forma...

Страница 85: ...ble containing MAC Address IP Address pairs that are manually entered probably by a network administrator Only clients with a MAC address listed in the MAC IP Address Table will be assigned an IP addr...

Страница 86: ...the pre determined time to delay PEF alerts after system power ups and resets Refer to Table 24 6 of the IPMI 1 5 Specification for more information at www intel com The options are No Delay 30 sec 60...

Страница 87: ...ation View Event Log Use this option to view the System Event Log Mark All Events as Read This option marks all events as read The options are OK and Cancel Clear Event Log This option clears the Even...

Страница 88: ...he Setup Utility View Only allows access to the Setup Utility but the fields cannot be changed Limited allows only limited fields to be changed such as Date and Time No Access prevents User access to...

Страница 89: ...ives This feature allows the user to specify the boot sequence from all available hard disk drives The settings are Disabled and a list of all hard disk drives that have been detected i e 1st Drive 2n...

Страница 90: ...n and reboot the computer Select Discard Changes and Exit from the Exit menu and press Enter Discard Changes Select this option and press Enter to discard all the changes and return to the AMI BIOS Ut...

Страница 91: ...ose which will not allow the system to continue the boot up procedure If a fatal error occurs you should consult with your system manufac turer for possible repairs BIOS Error Beep Codes Beep Code Err...

Страница 92: ...A 2 SUPERSERVER 6026T URF User s Manual Notes...

Страница 93: ...iver displays When the Windows OS Setup screen appears press S to specify additional 3 device s Insert the driver diskette Intel AA RAID Windows XP 2003 2008 Vista Driver 4 for ICH10R into the floppy...

Страница 94: ...th the OS installation The Windows OS Setup screen will display 2 From the Windows OS Setup screen press the Enter key The Windows 3 OS Setup will automatically load all device files and then continue...

Страница 95: ...3 1066 800 SDRAM or 24 GB of unbuffered ECC DDR3 1333 1066 800 SDRAM See the memory section in Chapter 5 for details SATA Controller Intel ICH10R on chip controller for six port Serial ATA RAID 0 1 5...

Страница 96: ...erature 40 to 70 C 40 to 158 F Operating Relative Humidity 20 to 95 non condensing Non operating Relative Humidity 5 to 95 non condensing Regulatory Compliance Electromagnetic Emissions FCC Class A EN...

Страница 97: ...C 3 Appendix C System Specifications Notes...

Страница 98: ...rform be reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro dis claims any and all liability and should buyer use or sell such p...

Отзывы: