Chapter 7: BIOS
7-17
Redirection After BIOS POST
Select Disabled to turn off Console Redirection after Power-On Self-Test
(POST). Select Always to keep Console Redirection active all the time after
POST. (Note: This setting may not be supported by some operating systems.)
Select Boot Loader to keep Console Redirection active during POST and Boot
Loader. The options are Disabled, Boot Loader, and
Always
.
Terminal Type
This feature allows the user to select the target terminal type for Console Redi-
rection. The options are ANSI,
VT100
, and VT-UTF8.
VT-UTF8 Combo Key Support
A terminal keyboard defi nition that provides a way to send commands from a
remote console. Available options are
Enabled
and Disabled.
Sredir Memory Display Delay
This feature defi nes the length of time in seconds to display memory information.
The options are
No Delay,
Delay 1 Sec, Delay 2 Sec, and Delay 4 Sec.
X
Hardware Health
Confi guration
This feature allows the user to monitor Hardware Health of the system and review
the status of each item when displayed.
CPU Overheat Alarm
This option allows the user to select the CPU Overheat Alarm setting which determines
when the CPU OH alarm will be activated to provide warning of possible CPU overheat.
Warning:
Any temperature that exceeds the CPU threshold temperature
predefi ned by the CPU manufacturer may result in CPU overheat or system
instability. When the CPU temperature reaches this predefi ned threshold, the
CPU and system cooling fans will run at full speed.
The options are:
The Early Alarm: Select this setting if you want the CPU overheat alarm (includ-
•
ing the LED and the buzzer) to be triggered as soon as the CPU temperature
reaches the CPU overheat threshold as predefi ned by the CPU manufacturer.
The Default Alarm
•
: Select this setting if you want the CPU overheat alarm
(including the LED and the buzzer) to be triggered when the CPU temperature
reaches about 5
o
C above the threshold temperature as predefi ned by the CPU
manufacturer to give the CPU and system fans additional time needed for CPU
and system cooling. (See the notes on P. 4-18 for more information.)
Содержание SuperServer 5016T-MR-LN4B
Страница 1: ...SUPER USER S MANUAL Revision 1 0a SUPERSERVER 5016T MRB SUPERSERVER 5016T MR LN4B...
Страница 5: ...v Preface Notes...
Страница 10: ...Notes SUPERSERVER 5016T MRB 5016T MR LN4B User s Manual x...
Страница 16: ...1 6 SUPERSERVER 5016T MRB 5016T MR LN4B User s Manual Notes...
Страница 28: ...2 12 SUPERSERVER 5016T MRB 5016T MR LN4B User s Manual Notes...
Страница 32: ...3 4 SUPERSERVER 5016T MRB 5016T MR LN4B User s Manual Notes...
Страница 98: ...A 2 SUPERSERVER 5016T MRB 5016T MR LN4B User s Manual Notes...
Страница 103: ...C 3 Appendix C System Specifications Notes...