ERVER 5016I-MT/5016I-MTF User's Manual
5-2 Motherboard
Installation
This section explains the fi rst step of physically mounting the X8SIE/X8SIE-F into
the SC813MTQ-350 chassis. Following the steps in the order given will eliminate
the most common problems encountered in such an installation. To remove the
motherboard, follow the procedure in reverse order.
Installing to the Chassis
Access the inside of the system (see procedure in Chapter 6).
1.
Make sure that the I/O ports on the motherboard align properly with their
2.
respective holes in the I/O shield at the back of the chassis.
Carefully mount the motherboard to the motherboard tray by aligning the
3.
board holes with the raised metal standoffs that are visible in the chassis. You
may need to add an extra standoff for the hole near the Fan 3 header.
Insert screws into all the mounting holes on your motherboard that line up
4.
with the standoffs and tighten until snug (if you screw them in too tight, you
might strip the threads).
Finish by replacing the top cover of the chassis.
5.
Note:
Metal screws provide an electrical contact to the serverboard ground to
provide a continuous ground for the system.
Warning:
To avoid damaging the serverboard and its components, do not apply
any force greater than 8 lbs. per square inch when installing a screw into a mount-
ing hole.
5-3 Connecting
Cables
Now that the motherboard is installed, the next step is to connect the cables to the
board. These include the data (ribbon) cables for the peripherals and control panel
and the power cables.
Connecting Data Cables
The cables used to transfer data from the peripheral devices have been carefully
routed to prevent them from blocking the fl ow of cooling air that moves through
the system from front to back. If you need to disconnect any of these cables, you
should take care to keep them routed as they were originally after reconnecting
them (make sure the red wires connect to the pin 1 locations). The following data
Содержание SuperServer 5016I-MT
Страница 1: ...SUPER SuperServer 5016I MT SuperServer 5016I MTF USER S MANUAL Revision 1 0...
Страница 5: ...v Preface Notes...
Страница 10: ...Notes SUPERSERVER 5016I MT 5016I MTF User s Manual x...
Страница 16: ...1 6 SUPERSERVER 5016I MT 5016I MTF User s Manual Notes...
Страница 30: ...3 4 SUPERSERVER 5016I MT 5016I MTF User s Manual Notes...
Страница 62: ...5 28 SUPERSERVER 5016I MT 5016I MTF User s Manual Notes...
Страница 70: ...6 8 SUPERSERVER 5016I MT 5016I MTF User s Manual Notes...
Страница 94: ...7 24 SUPERSERVER 5016I MT 5016I MTF User s Manual Notes...
Страница 96: ...A 2 SUPERSERVER 5016I MT 5016I MTF User s Manual Notes...
Страница 101: ...C 3 Appendix C System Specifications Notes...