SUPERSERVER 2027TR-H72RF/H72QRF/H72FRF USER'S MANUAL
6-4 Air
Shrouds
Air shrouds concentrate airfl ow to maximize fan effi ciency. The SC217 chassis
requires air shrouds for each motherboard node. Air shrouds vary depending upon
the motherboard used. See the illustrations below.
Installing an Air Shroud (Figure 6-3)
1. Make sure that the motherboard expansion card (if applicable) and all
components are properly installed in each motherboard node.
2. Place the fi rst air shroud over the motherboard, as shown below. The air
shroud sits behind the system fans and goes over the top of the motherboard
and its components.
3. Repeat the procedure for the remaining three motherboard nodes.
Figure 6-3: Installing the Air Shroud
Air Shroud