3-2
SUPERSERVER 1028GR-TR/TRT User's Manual
3-2 Control Panel Buttons
The chassis includes two push-buttons.
UID
: The reset button is used to reboot the system.
Power
: The main power switch is used to apply or remove power from the power
supply to the server system. Turning off system power with this button removes the
main power but keeps standby power supplied to the system. Therefore, you must
unplug system before servicing.
3-3 Control Panel LEDs
There are five LEDs that provide status information about the system.
Information LED
: Alerts operator of several states, as noted in the table below.
Information LED
Status
Description
Continuously on and red
An overheat condition has occured.
(This may be caused by cable congestion.)
Blinking red (1Hz)
Fan failure, check for an inoperative fan.
Blinking red (0.25Hz)
Power failure, check for a non-operational power supply.
Solid blue
Local UID has been activated. Use this function to locate
the server in a rack mount environment.
Blinking blue
Remote UID is on. Use this function to identify the
server from a remote location.
Содержание SUPERSERVER 1028GR-TR
Страница 1: ...SUPER USER S MANUAL Revision 1 0 SUPERSERVER 1028GR TR 1028GR TRT 2 1...
Страница 12: ...1 6 SUPERSERVER 1028GR TR TRT User s Manual Notes...
Страница 22: ...2 10 SUPERSERVER 1028GR TRT TR User s Manual Notes...
Страница 46: ...4 20 SUPERSERVER 2027TR D70RF User s Manual Notes...
Страница 84: ...6 12 SUPERSERVER 1028GR TR TRT Series User s Manual Notes...
Страница 124: ...7 40 SuperServer 1028GR TR TRT User s Manual Notes...
Страница 126: ...A 2 SUPERSERVER 1028GR TR TRT User s Manual Notes...
Страница 130: ...B 4 SUPERSERVER 1028GR TR TRT User s Manual Notes...