SC808 Chassis Manual
5-6
5-4 Installing the Motherboard
I/O Shield
The I/O shield holds the motherboard ports in place. The I/O shield does not require
installation, however, the motherboard must match up with the I/O shield.
Permanent and Optional Standoffs
Standoffs prevent short circuits by securing space between the motherboard and
the chassis surface. The SC808 chassis includes permanent standoffs in locations
used by the motherboards. These standoffs accept the rounded Phillips head screws
included in the SC808 accessories packaging.
Some motherboards require additional screws for heatsinks, general components
and for stability. Optional standoffs are used for these motherboards.
To use an optional standoff, you must place a hexagonal screw through the bottom
the chassis and secure the screw with the hexagonal nut (rounded side up).
Depending upon the configuration of the motherboard being used, it is also pos
-
sible that some of the optional standoffs which are pre-installed in the chassis, may
need to be removed.
I/O Shields
Figure 5-6: I/O Shield Placement