4-3
Chapter 4 System Interface
Information LED
: Alerts operator of several states, as noted in the table below.
Information LED
Status
Description
Continuously on and red
An overheat condition has occured.
(This may be caused by cable congestion.)
Blinking red (1Hz)
Fan failure, check for an inoperative fan.
Blinking red (0.25Hz)
Power failure, check for a non-operational power supply.
Solid blue
Local UID has been activated. Use this function to locate
the server in a rack mount environment.
Blinking blue
Remote UID is on. Use this function to identify the
server from a remote location.
Overheating
There are several possible responses if the system overheats.
If the system overheats:
1. Use the LEDs to determine the nature of the overheating condition.
2.
Confirm that the chassis cover is installed properly.
3. Check the routing of the cables and make sure all fans are present and operat-
ing normally.
4. Verify that the heatsinks are installed properly.