2-15
Chapter 2: Chassis Description and Installation Instructions
After you have installed the inner rails on the chassis, you are ready to install the
outer rails of rail assemblies to the rack.
(* The rails are designed to fit in the racks with the depth of 28" to 33".)
Procedures
1. In the package, locate a pair of front (-short) and rear (-long) brackets. Please
note that the brackets are marked with Up/Front Arrows (-front) and Up/Rear
arrows (-rear).
2. Secure the front (-short) bracket (marked with the Up/Front arrows) to the
outer rail with two Type G screws.
3. Attach the rear (-long) bracket to the other end of the outer rail and secure the
rear (long) bracket to the outer rail with a Type G screw as shown below.
4. Measure the depth of your rack and adjust the length of the rails accordingly.
5. Repeat the same steps to install the other outer rail on the chassis.
6. Secure both outer rail assemblies to the rack with Type H screws and Type I
washers.
3
G
4
I
2
G
H
6
J-1 Rack Installation for the Traditional UP Design (*Optional
for the SC513)