4-14
H8DM8-2/H8DME-2 User’s Manual
the CPU temperature has dropped to 5 degrees below the threshold set. The
default setting is
72
o
C
.
System Fan Monitor
Fan Speed Control
This feature allows the user to determine how the system will control the speed
of the onboard fans. Select "Workstation" if your system is used as a Worksta-
tion. Select "Server" if your system is used as a Server. Select "Disable" to
disable the fan speed control function to allow the onboard fans to continuously
run at full speed (12V). The options are
1) Disable (Full Speed)
2) Server
3) Workstation.
FAN1 Speed through FAN8 Reading
The speeds of the onboard fans (in rpm) are displayed here.
Other items in the submenu are systems monitor displays for the following
information:
CPU1 Temperature, CPU2 Temperature (for 2U systems), System Temperature,
VCoreA, VCoreB (for 2U systems), HT Voltage, CPU1 Mem VTT, CPU2 Mem
VTT, CPU1 Mem, CPU2 Mem, VDD, 1.5V, MCP55 VCcore, 3.3V, 12V, -12V, 5V
VSB and VBAT.
IPMI Confi guration
View BMC System Event Log
Pressing the Enter key will open the following settings. Use the "+" and "-"
keys to navigate through the system event log.
Clear BMC System Event Log
Selecting this and pressing the Enter key will clear the BMC system event log.
Set LAN Confi guration
Use the "+" and "-" keys to choose the desired channel number.