Chapter 2: Workstation Installation

2-9

Figure 2-5.  Installing the Rack Rails

Содержание 7047AX-72RF

Страница 1: ...SUPERSERVER 7047AX TRF 7047AX 72RF SUPER USER S MANUAL Revision 1 0 ...

Страница 2: ...f any such disputes Super Micro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commerci...

Страница 3: ...SQ chassis Chapter 2 Server Installation This chapter describes the steps necessary to install the system into a rack and check out the server configuration prior to powering up the system If your server was ordered without the processor and memory components this chapter will refer you to the appropriate sections of the manual for their installation Chapter 3 System Interface Refer to this chapte...

Страница 4: ...E 747TG R1K28B SQ 4U Tower rackmount server chassis You should follow the procedures given in this chapter when installing removing or reconfiguring SATA or peripheral drives and when replacing system power supply units and cooling fans Chapter 7 BIOS The BIOS chapter includes an introduction to BIOS and provides detailed information on running the CMOS Setup Utility Appendix A BIOS POST Messages ...

Страница 5: ...ing the System 2 1 2 3 Preparing for Setup 2 2 Choosing a Setup Location 2 2 Rack Precautions 2 2 Workstation Precautions 2 2 Rack Mounting Considerations 2 3 Ambient Operating Temperature 2 3 Reduced Airflow 2 3 Mechanical Loading 2 3 Circuit Overloading 2 3 Reliable Ground 2 4 2 4 Installing the Chassis onto a Rack 2 4 Removing the Chassis Cover and Feet 2 4 Identifying the Sections of the Rack ...

Страница 6: ...ion 4 1 Installation Instructions 4 4 Circuit Breaker 4 5 Power Disconnection Warning 4 6 Equipment Installation 4 8 Restricted Area 4 9 Battery Handling 4 10 Redundant Power Supplies 4 12 Backplane Voltage 4 13 Comply with Local and National Electrical Codes 4 14 Product Disposal 4 15 Hot Swap Fan Warning 4 16 Power Cable and AC Adapter 4 18 Chapter 5 Advanced Serverboard Setup 5 1 Handling the S...

Страница 7: ...Sensitive Devices 6 2 Precautions 6 2 6 2 Control Panel 6 2 6 3 System Cooling 6 3 System Fan Failure 6 3 Replacing System Fans 6 3 6 4 Power Supply 6 5 Power Supply Failure 6 5 Replacing the Power Supply 6 5 Power Supply Connections 6 6 6 5 Configuring the Storage Module 6 7 Tower or Rack Configuration 6 7 Rotating the Storage Module 6 8 Installing Drives in the Storage Module 6 9 Removing a Driv...

Страница 8: ...up Configurations 7 4 7 4 Overclocking 7 25 7 5 Event Logs 7 27 7 6 IPMI 7 29 7 7 Boot 7 31 7 8 Security 7 32 7 9 Save Exit 7 33 Appendix A BIOS Error Beep Codes Appendix B System Specifications Table of Contents viii ...

Страница 9: ...components have been included with the workstation as listed below Two 80 mm exhaust fans FAN 0082L4 Four 92 x 38 mm front fans FAN 0114L4 SATA accessories One HD backplane BPN SAS 747TQ Eight 3 5 hard disk drive trays MCP 220 00094 0B Three 5 25 drive trays MCP 220 00073 0B One SuperWorkstation 7047AX TRF 7047AX 72RF Quick Reference Guide Optional One 4U 17 2 width rack rail set MCP 290 00059 0N ...

Страница 10: ...ECC 1600 1333 1066 800 MHz 4 channel memory modules Modules of the same size and speed are recommended See Chapter 5 for details SAS A total of eight SAS 2 0 ports are provided with an LSI 2208 SAS controller RAID levels 0 1 5 10 50 and 60 are supported Note The operating system you use must have RAID support to enable the hotswap capability and RAID function of the SAS drives Serial ATA A SATA co...

Страница 11: ...7TG R1K28B SQ chassis includes a 1280W high efficiency redundant 1 1 power supply consisting of two power supply modules In the unlikely event a power supply module fails replacement is simple and can be done without tools The AC power cord should be removed from the system before servicing or replacing a power supply module See Chapter 6 for details Mounting Rails optional The CSE 747TG R1K28B SQ...

Страница 12: ...am Note This is a general block diagram Please see Chapter 5 for details 1 4 1 3 1 2 Intel E5 2600 8 SNB CORE DDR3 2 1 3 P0 P1 DMI2 LAN X540 USB 3 0 REAR COM1 internal 1394 SPI BMC WPCM450 VGA USB 3 0 LANE1 2 3 4 LANE6 PCH C602 LANE7 LANE8 PCI 0 3 0 3 0 7 SCU DMI2 4 GB s DMI2 3 0 Gb S FRONT SAS2208 PCI E X16 G3 PCI E X8 G3 PCI E X4 PCI E X8 G3 PCI E X8 G3 PCI E X16 G3 QPI 8G Intel E5 2600 8 SNB CO...

Страница 13: ...dress Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma supermicro nl Customer Support Asia Pacific Address Super Micro Computer Inc 4F No 232 1 Liancheng Rd Chung Ho Dist New Taipei City 235 Taiwan Tel 886 2 8226 3990 Fax 886 2 8226 3...

Страница 14: ...n any way If the workstation itself shows damage you should file a damage claim with the carrier who delivered it Decide on a suitable location for setting up and operating the SuperWorkstation 7047AX TRF 7047AX 72RF It should be situated in a clean dust free area that is well ventilated Avoid areas where heat electrical noise and electromagnetic fields are generated You will also need it placed n...

Страница 15: ...tallation only in a Restricted Access Location dedicated equipment rooms service closets and the like Rack Precautions Ensure that the leveling jacks on the bottom of the rack are fully extended to the floor with the full weight of the rack resting on them In single rack installation stabilizers should be attached to the rack In multiple rack installations the racks should be coupled together Alwa...

Страница 16: ...ng tempera ture of the rack environment may be greater than the ambient temperature of the room Therefore consideration should be given to installing the equipment in an environment compatible with the manufacturer s maximum rated ambient tempera ture Tmra Reduced Airflow Equipment should be mounted into a rack so that the amount of airflow required for safe operation is not compromised Mechanical...

Страница 17: ...ith stabilizing devices install the stabilizers before mounting or servicing the unit in the rack 2 4 Installing the Chassis onto a Rack This section provides information on installing the SC747 chassis into a rack unit with the optional 4U 17 2 width rail set MCP 290 00059 0B There are a variety of rack units on the market which may mean the assembly procedure will differ slightly You should also...

Страница 18: ...m sliding Using a flat head screwdriver gently lift the foot lock upward and slide the foot toward the rear of the chassis 4 Repeat steps 2 and 3 with each remaining foot Identifying the Sections of the Rack Rails The chassis package includes two rack rail assemblies in the rack mounting kit Each assembly consists of two sections an inner fixed chassis rail that secures directly to the workstation...

Страница 19: ...2 6 SUPERSERVER 7047AX TRF 7047AX 72RF User s Manual Figure 2 1 Removing the Feet and Chassis Top Cover Chassis Cover Chassis Feet Chassis Cover Lock ...

Страница 20: ...handle screws 2 Align the chassis handle with the front of the chassis and secure with the three chassis handle screws 3 Repeats steps 1 and 2 with the other handle 4 Locate the inner rails and screws in the shipping package 5 Align the inner rails against the chassis as shown Confirm that the rails are flushed against the edge of the chassis 6 Tighten the screws Do not over tighten 7 Repeat steps...

Страница 21: ...racket 2 Adjust both the brackets to the proper distance so that the rail fits snugly into the rack 3 Secure the rear of the outer rail with two M5 screws and the rear of the rack Note The outer rail is adjustable from approximately 26 to 38 25 4 Repeat steps 1 3 for the left outer rail Figure 2 4 Assembling the Outer Rails Slide into the Inner Rail Secure to the Rear of the Rack Attach to Middle ...

Страница 22: ...Chapter 2 Workstation Installation 2 9 Figure 2 5 Installing the Rack Rails ...

Страница 23: ... even on both sides you may have to depress the locking tabs when inserting When the chassis has been pushed completely into the rack you should hear the locking tabs click into the locked position Stability hazard The rack stabilizing mechanism must be in place or the rack must be bolted to the floor before you slide the unit out for servicing Failure to stabilize the rack can cause the rack to t...

Страница 24: ...nd need to return the chassis to tower mounting Installing the Chassis Cover Installing the Cover 1 Remove the rack mount ears 2 Align the cover post with the corresponding holes on the top of the chassis and place the cover on top of the chassis The cover should overhang approximately one half inch over the front of the chassis 3 Slide the chassis cover toward the rear of the chassis to lock the ...

Страница 25: ...is foot in the foot receptacle and slide the foot toward the front of the chassis The foot should lock into place 2 Secure the foot to the chassis using one screw enclosed in the packaging 3 Repeat steps 1 and 2 for the remaining three chassis feet Figure 2 7 Placing Chassis Feet Chassis Foot Receptacle Chassis Foot Chassis Screw ...

Страница 26: ...rriers to keep you constantly informed of the overall status of the system as well as the activity and health of specific components There are two buttons on the chassis a control panel a reset button and an on off switch This chapter explains the meanings of all LED indicators and the appropriate response you may need to take Figure 3 1 Front LEDs ...

Страница 27: ...n power but keeps standby power supplied to the system Therefore you must unplug system before servicing Reset The reset button is used to reboot the system 3 3 Control Panel LEDs The control panel located on the front of the SC747TQ R1K28 SQ chassis has five LEDs These LEDs provide you with critical information related to different parts of the system This section explains what each LED indicates...

Страница 28: ...ch may be caused by cables obstructing the airflow in the system or the ambient room temperature being too warm Check the routing of the cables and make sure all fans are present and operating normally You should also check to make sure that the chassis covers are installed Finally verify that the heatsinks are installed properly This LED will remain flashing or on as long as the overheat conditio...

Страница 29: ...n LED When illuminated this green LED on the front of the drive carrier indicates drive activity A connection to the SATA backplane enables this LED to blink on and off when that particular drive is being accessed Red The red LED indicates a SATA drive failure If one of the SATA drives fail you should be notified by your system management software ...

Страница 30: ... configuring components in the Supermicro chassis These warnings may also be found on our web site at http www supermicro com about policies safety_information cfm Warning This warning symbol means danger You are in a situation that could cause bodily injury Before you work on any equipment be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preve...

Страница 31: ...trará el número que le ayudará a encontrar el texto traducido en el apartado de traducciones que acompaña a este dispositivo GUARDE ESTAS INSTRUCCIONES IMPORTANTES INFORMATIONS DE SÉCURITÉ Ce symbole d avertissement indique un danger Vous vous trouvez dans une situation pouvant entraîner des blessures ou des dommages corporels Avant de travailler sur un équipement soyez conscient des dangers liés ...

Страница 32: ... aan enige apparatuur gaat werken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan het eind van elke waarschuwing om deze te herleiden naar de desbetreffende locatie BEWAAR DEZE INSTRUCTIES ً ف اًك أى ٌوكي حالة ً ف تتسبب اصابة جسذٌة الزهز هذا ًٌ ٌع خطز ...

Страница 33: ...nes de instalación antes de conectar el sistema a la red de alimentación Attention Avant de brancher le système sur la source d alimentation consulter les directives d installation 設置手順書 システムを電源に接続する前に 設置手順書をお読み下さい ال إرشادات اقر تركيب توصيل قبل إلى النظام للطاقة مصدر לקרוא יש למקור המערכת חיבור לפני התקנה הוראות את מתח 시스템을 전원에 연결하기 전에 설치 안내를 읽어주십시오 Waarschuwing Raadpleeg de installatie instructi...

Страница 34: ...liza el sistema de protección contra cortocircuitos o sobrecorrientes del edificio Asegúrese de que el dispositivo de protección no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit dépend de l installation électrique du local Vérifiez que le courant nominal du dispositif de protection n est pas supérieur à 250 V 20 A על מסתמך זה ...

Страница 35: ...rnt wird bevor es auf den Chassisinnenraum zurückgreift um Systemsbestandteile anzubringen oder zu entfernen Warning The system must be disconnected from all sources of power and the power cord removed from the power supply module s before accessing the chassis interior to install or remove system components 경고 이 제품은 전원의 단락 과전류 방지에 대해서 전적으로 건물의 관련 설비에 의존합니다 보호장치의 정격이 반드시 250V 볼트 20A 암페어 를 초과하지 않도록...

Страница 36: ... ou enlever des composants de systéme חשמלי ניתוק מפני אזהרה אזהרה החשמל מקורות מכל המערכת את לנתק יש להסיר ויש מהספק החשמלי כבל את התקנ לצורך המארז של הפנימי לחלק גישה לפני ת הסר או ת רכיבים فصم يجب اننظاو جميع من مصادر انطاقت وإزانت انكهرباء سهك من وحدة امداد انطاقت قبم إنى انىصىل انداخهيت انمناطق ن ههيكم إزانت أو نتثبيج مكىناث الجهاز 경고 시스템에 부품들을 장착하거나 제거하기 위해서는 섀시 내부에 접근하기 전에 반드시 전원 공급장치로부터 연결...

Страница 37: ...rsonal gestattet werden Advertencia Solamente el personal calificado debe instalar reemplazar o utilizar este equipo Attention Il est vivement recommandé de confier l installation le remplacement et la maintenance de ces équipements à des personnels qualifiés et expérimentés אזהרה רש בלבד מוסמך צוות את להחליף להתקין אי הציוד עבור שירות לתת או הציוד والمدربيه و لتزكيب استبدال أو خدمة الجهاس هذا يسم...

Страница 38: ... in Bereichen mit beschränktem Zutritt vorgesehen Der Zutritt zu derartigen Bereichen ist nur mit einem Spezialwerkzeug Schloss und Schlüssel oder einer sonstigen Sicherheitsvorkehrung möglich Advertencia Esta unidad ha sido diseñada para instalación en áreas de acceso restringido Sólo puede obtenerse acceso a una de estas áreas mediante la utilización de una herramienta especial cerradura con lla...

Страница 39: ...ق محظورة تم انىص َمكن ً إن ىل منطقت محظورة فقط استخذاو خالل من خاصت أداة أو ٌ أ نال أخري وسُهت مألما ومفتاح قفم 경고 이 장치는 접근이 제한된 구역에 설치하도록 되어있습니다 특수도구 잠금 장치 및 키 또는 기타 보안 수단을 통해서만 접근 제한 구역에 들어갈 수 있습니다 Waarschuwing Dit apparaat is bedoeld voor installatie in gebieden met een beperkte toegang Toegang tot dergelijke gebieden kunnen alleen verkregen worden door gebruik te maken van speciaal gereedschap...

Страница 40: ...ipo o el equivalente recomendado por el fabricante Desechar las baterías gastadas según las instrucciones del fabricante אזהרה סכנת קיימת פיצוץ תקינה לא בדרך והוחלפה במידה הסוללה של להחליף יש בסוג הסוללה את מ התואם חברת מומל יצרן צת הסוללות סילוק המשומשות לבצע יש היצרן הוראות לפי خطر هناك من اسحبذال حالة في انفجار البطارية صحيحة غير بطريقة فعليل البطارية اسحبذال فقط النىع بنفس يعادلها ما أو مما أو...

Страница 41: ...tion Cette unité peut avoir plus d une connexion d alimentation Pour supprimer toute tension et tout courant électrique de l unité toutes les connexions d alimentation doivent être débranchées Redundant Power Supplies Warning This unit might have more than one power supply connection All connections must be removed to de energize the unit 冗長電源装置 このユニッ トは複数の電源装置が接続されている場合があります ユニッ トの電源を切るためには すべての接...

Страница 42: ...idado cuando lo revise Attention Lorsque le système est en fonctionnement des tensions électriques circulent sur le fond de panier Prendre des précautions lors de la maintenance Warning Hazardous voltage or energy is present on the backplane when the system is operating Use caution when servicing قد لهذا يكون ال جهاز اتصاالت عدة بوحدات الطاقة امداد إزالة يجب االتصاالت كافة لعسل ال وحدة عن الكهرباء...

Страница 43: ... del equipo debe cumplir con las normas de electricidad locales y nacionales هناك خطز مه الكهزبائي التيار على المىجىدة أوالطاقة اللىحة يكىن عندما النظام يعمل عند حذرا كه خدمة الجهاس هذا 경고 시스템이 동작 중일 때 후면판 Backplane 에는 위험한 전압이나 에너지가 발생 합니다 서비스 작업 시 주의하십시오 Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is geboden tijden...

Страница 44: ...اويه والىطىية المحلية المتعلقة بالكهرباء Attention L équipement doit être installé conformément aux normes électriques nationales et locales 경고 현 지역 및 국가의 전기 규정에 따라 장비를 설치해야 합니다 Waarschuwing Bij installatie van de apparatuur moet worden voldaan aan de lokale en nationale elektriciteitsvoorschriften 製品の廃棄 この製品を廃棄処分する場合 国の関係する全ての法律 条例に従い処理する必要が あります 警告 本产品的废弃处理应根据所有国家的法律和规章进行 警告 本產品的廢棄處理應根據所有國家的法律和規...

Страница 45: ... l environnement Renseignez vous auprès de l organisme compétent Warning The fans might still be turning when you remove the fan assembly from the chassis Keep fingers screwdrivers and other objects away from the openings in the fan assembly s housing Hot Swap Fan Warning המוצר סילוק אזהרה ו להנחיות בהתאם להיות חייב זה מוצר של סופי סילוק המדינה חוקי النهائي التخلص من المنتج هذا معه التعامل ينبغي ل...

Страница 46: ...rde à ce que doigts tournevis et autres objets soient éloignés du logement du bloc ventilateur אזהרה חלקי את מסירים כאשר יש עובדים עדיין והמאווררים יתכן מהמארז המאוורר להרחיק ל המאוורר בתוך מהפתחים שונים עבודה וכלי האצבעות את בטוח מרחק انممكه مه انمراوح أن تسال ال إزانة تدورعند كتهة انمروحة انهيكم مه يجب إبقاء األصابع و انبراغي مفكات األشياء مه وغيرها بعيدا عه انفتحات في كتهة انمروحة 경고 섀시로부터 팬 조립...

Страница 47: ...er CSA auf der Code für alle anderen elektrischen Geräte als Produkte von Supermicro nur bezeichnet gezeigt haben Advertencia Al instalar el producto utilice los cables de conexión previstos o designados los cables y adaptadores de CA La utilización de otros cables y adaptadores podría ocasionar un mal funcionamiento o un incendio Aparatos Eléctricos y la Ley de Seguridad del Material prohíbe el u...

Страница 48: ...צוין שלא تركيب عىذ استخذام يجب الجهاز و التىصيل كابالث الكهربائيت الكابالث ومحىالث المتردد التيار أن أي استخذام كابالث ومحىالث أخري يتسبب في عطل حذوث حريق أو التي لك تىفيرها تم المىتج مع UL أو CSA الكهربائيت األجهسة ومىاد قاوىن السالمت استخذام يحظر الكابالث قبل مه معتمذة Supermicro أجهسة أخري كهربائيت غير المىتجاث المعيىت قبل مه ألي UL CSA تحمل التي عالمت 경고 제품을 설치할 때에는 제공되거나 지정된 연결케이블과 전원케이블 AC어댑...

Страница 49: ...4 20 SUPERSERVER 7047AX TRF 7047AX 72RF User s Manual Notes ...

Страница 50: ...t to handle them very carefully see previous chapter To prevent the serverboard from bending keep one hand under the center of the board to support it when handling The following measures are generally sufficient to protect your equipment from electric static discharge Precautions Use a grounded wrist strap designed to prevent Electrostatic Discharge ESD Touch a grounded metal object before removi...

Страница 51: ...with their locations noted should be connected See the serverboard layout for connector locations SATA drive data cables SATA3 S SATA0 S SATA3 Control Panel cable JF1 Important Make sure the the cables do not come into contact with the fans Connecting Power Cables The X9DAX 7F iF has a 24 pin proprietary power supply connector JPW1 for connection to the ATX power supply In addition there are two 8...

Страница 52: ...0 Figure 5 1 Control Panel Header Pins 5 3 I O Ports The I O ports are color coded in conformance with the PC 99 specification See Figure 5 2 below for the colors and locations of the various I O ports 1 1 1 7 1 5 1 6 1 4 1 3 1 2 1 8 1 9 1 10 1 11 1 12 1 13 1 14 1 15 1 16 Figure 5 2 I O Ports Power Button OH Fan Fail LED 1 NIC1 LED Reset Button 2 HDD LED Power LED Reset PWR Vcc Vcc Vcc Vcc Ground ...

Страница 53: ... adding re moving or changing any hardware components Make sure that you install the processor into the CPU socket before you install the CPU heatsink If you buy a CPU separately make sure that you use an Intel certified multi directional heatsink only Make sure to install the serverboard into the chassis before you install the CPU heatsinks When receiving a serverboard without a processor pre ins...

Страница 54: ... remove the WARNING plastic cap from the socket 5 Use your thumb and index finger to hold the CPU by its edges Align the CPU keys which are semi circle cutouts against the socket keys 6 Once they are aligned carefully lower the CPU straight down into the socket Do not drop the CPU on the socket Do not move the CPU horizontally or vertically and do not rub the CPU against any pins of the socket whi...

Страница 55: ...d double check that the CPU is aligned properly 7 With the CPU in the socket inspect the four corners of the CPU to make sure that they are flush with the socket 8 Close the load plate Lock the lever labeled Close 1st then lock the lever labeled Open 1st Use your thumb to gently push the load levers down until the lever locks 9 Repeat steps to install a CPU to socket 2 OPEN1st OPEN1st Lever Lock P...

Страница 56: ...e do not recommend removing the CPU or the heatsink However if you do need to uninstall the heatsink please follow these instructions to avoid damaging the CPU or the CPU socket Installation and Removal of the Heatsink Uninstalling the Heatsink 1 Unscrew and remove the heatsink screws in the sequence shown in the picture above 2 Hold the heatsink as shown in the picture on the right and gently wri...

Страница 57: ... Figure 5 3 3 Gently press down on the DIMM module until it snaps into place in the slot Repeat for all modules CAUTION Exercise extreme care when installing or removing DIMM modules to prevent any possible damage 5 6 Installing Memory To Install Insert module vertically and press down until it snaps into place Pay attention to the alignment notch at the bottom To Remove Use your thumbs to gently ...

Страница 58: ...Us DIMMs CPU and Memory Population Configuration Table For memory to work properly please install as shown below 1 CPU 2 DIMMs CPU1 P1 DIMMA1 P1 DIMMB1 1 CPU 4 DIMMs CPU1 P1 DIMMA1 P1 DIMMB1 P1 DIMMC1 P1 DIMMD1 1 CPU 5 8 DIMMs CPU1 P1 DIMMA1 P1 DIMMB1 P1 DIMMC1 P1 DIMMD1 Any memory pairs in P1 DIMMA2 P1 DIMMB2 P1 DIMMC2 P1 DIMMD2 slots 2 CPUs 4 DIMMs CPU1 CPU2 P1 DIMMA1 P1 DIMMB1 P2 DIMME1 P2 DIMM...

Страница 59: ...d Memory List posted on our website at http www supermicro com support resources mem cfm Populating RDIMM ECC Memory Modules Intel E5 2600 Series Processor RDIMM Memory Support Ranks Per DIMM Data Width Memory Capacity Per DIMM See the Note Below Speed MT s and Voltage Validated by Slot per Channel SPC and DIMM Per Channel DPC 1 Slot Per Channel 2 Slots Per Channel 1DPC 1DPC 2DPC 1 35V 1 5V 1 35V ...

Страница 60: ...6 1333 1066 1333 1066 1066 1333 Note For detailed information on memory support and updates please refer to the SMC Recommended Memory List posted on our website at http www supermicro com support resources mem cfm Other Important Notes and Restrictions For the memory modules to work properly please install DIMM modules of the same type same speed and same operating frequency Mixing of RDIMMs UDIM...

Страница 61: ...he top of the PCI slot bracket Gently apply pressure to the middle of the release tab to unlock the PCI slot bracket 2 Pull the release tab upward 3 Remove the screw holding the bracket in place and pull the bracket from the chassis 4 Install your PCI card or other add on card into the PCI slot bracket and serverboard 5 Push the PCI bracket release tab down until it locks into place with an audibl...

Страница 62: ... 3 0 X8 UIO slot CPU2 SLOT5 PCI E 3 0 X8 USB4 USB3 0 2 3 CPU2 SLOT6 PCI E 3 0 X8 CPU2 SLOT7 PCI E 3 0 X8 P1 DIMMB2 P1 DIMMB1 P1 DIMMA2 P1 DIMMA1 P1 DIMMC1 P1 DIMMD1 P1 DIMMC2 P1 DIMMD2 P2 DIMME1 P2 DIMMF1 P2 DIMME2 P2 DIMMF2 AUDIO FP P2 DIMMH1 P2 DIMMH2 P2 DIMMG1 P2 DIMMG2 USB2 0_0 3 PWR I2C USB3 0_0 1 HD AUDIO CNF2 JD1 Battery Processor 2 Processor 1 LAN1 LAN2 VGA Audio CTRL LAN CTRL BMC PHY SAS ...

Страница 63: ... 1 6 JSD1 SATA DOM Device_On_Module Power Connector JSTBY1 Standby Power Header JTPM1 TPM Trusted Platform Module Port 80 Header JVGA VGA Port LAN1 2 Gigabit Ethernet LAN Ports 1 2 X9DAX iF 7F Only 10G Ethernet LAN Ports 1 2 X9DAX iTF 7TF Only L SAS 0 3 4 7 Serial_Attached SCSI 2 0 Connections 0 3 4 7 from the LSI SAS 2208 Controller X9DAX 7F 7TF Only I SATA0 5 Intel SB SATA Connectors 0 5 SATA 0 ...

Страница 64: ...lled SCU SGPIO 1 Serial Link General_Purpose IO Header for S SATA Connections 0 3 T SGPIO 1 2 Serial Link General_Purpose IO Headers for I SATA Connections 0 2 3 5 USB 2 0 0 3 Back Panel USB 2 0 Ports 0 1 2 3 USB 2 0 4 Front Panel Accessible Type A USB 2 0 Header USB 4 J25 USB 2 0 5 6 Front Panel Accessible USB 2 0 Connections 5 6 J23 USB 3 0 0 1 Back Panel USB 3 0 Ports 0 1 USB 3 0 2 3 Front Pane...

Страница 65: ...ition 13 3 3V 1 3 3V 14 12V 2 3 3V 15 COM 3 COM 16 PS_ON 4 5V 17 COM 5 COM 18 COM 6 5V 19 COM 7 COM 20 Res NC 8 PWR_OK 21 5V 9 5VSB 22 5V 10 12V 23 5V 11 12V 24 COM 12 3 3V 12V 8 pin PWR Con nector Pin Definitions Pins Definition 1 through 4 Ground 5 through 8 12V Required Power LED The Power LED connection is located on pins 15 and 16 of JF1 Refer to the table on the right for pin definitions NMI...

Страница 66: ...efer to the table on the right for pin definitions PWR Fail LED Pin Definitions JF1 Pin Definition 5 3 3V 6 PWR Supply Fail Overheat OH Fan Fail LED Connect an LED cable to pins 7 and 8 of JF1 to provide advanced warnings of chassis overheating and fan failure Refer to the table on the right for pin definitions OH Fan Fail PWR Fail LED Pin Definitions JF1 Pin Definition 7 Vcc 8 OH Fan Fail LED OH ...

Страница 67: ...ial Bus 2 0 ports USB 2 0 Ports 0 3 and two USB 3 0 Ports USB 3 0 Ports 0 1 are located on the I O backplane In addition two USB 2 0 ports USB 5 6 and a Type A USB connector USB4 located close to the Intel PCH chip provides front USB access Also two USB 3 0 ports USB 3 0 Ports 2 3 are located next to Fan 3 to provide front access USB Cables are not included See the tables on the right for pin defi...

Страница 68: ...1 Clock 2 Data 3 PWR Fail 4 Ground 5 3 3V IPMB A System Management Bus header for IPMI 2 0 is located at JIPMB1 Connect the appropriate cable here to use the IPMB I2 C connection on your system IPMB Header Pin Definitions Pin Definition 1 Data 2 Ground 3 Clock 4 No Connection T SGPIO 1 2 SCU SGPIO 1 Headers Three SGPIO Serial Link General Purpose Input Output headers are located on the motherboard...

Страница 69: ... 4 GND 5 PTPB1 6 PTPB1 7 PWR 1394a 8 PWR 1394a 10 Shield GND DOM Power Connector A power connector for SATA DOM Disk_ On_Module devices is located at JSD1 Connect an appropriate cable here to provide backup power support for your SATA devices to retain cache data during power outage See the table on the right for pin definitions DOM PWR Pin Definitions Pin Definition 1 5V 2 Ground 3 Ground Overhea...

Страница 70: ...or pin definitions TPM Port 80 Header Pin Definitions Pin Definition Pin Definition 1 LCLK 2 GND 3 LFRAME 4 KEY 5 LRESET 6 5V X 7 LAD 3 8 LAD 2 9 3 3V 10 LAD1 11 LAD0 12 GND 13 SMB_CLK4 14 SMB_DAT4 15 3V_DUAL 16 SERIRQ 17 GND 18 CLKRUN X 19 LPCPD 20 LDRQ X Ethernet Ports Two Ethernet ports LAN1 2 are located on the I O backplane on the motherboard These ports support Gigabit LAN connections on the...

Страница 71: ...OM devices DOM PWR Pin Definitions Pin Definition 1 5V 2 Ground 3 Ground Front Panel Audio Header Front Panel Audio header is located at AUDIO_FP Connect a cable to this header to use front panel audio device To use the FP Audio for 97 Audio close pins 1 2 of jumper JPAC1 To use this header for High Definition Audio close pins 1 2 of jumper JHD_AC1 SPDIF_In Header A SPDIF In Sony Philips Digital I...

Страница 72: ...g 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS To clear CMOS 1 First power down the system and unplug the power cord s 2 With the power disconnected short the CMOS pads with a metal object such as a small screwdriver 3 Remove the screwdriver or shortin...

Страница 73: ...default setting which will allow the system to run at the normal speed for system stability Close pins 1 and 2 to enable overclocking for maximal system speed and performance CMOS Default Setting Select Jumper Settings Jumper Setting Definition Open Default CMOS Manufacture Default Select Normal Close Overclocking Enabled 1394a Enable Disable Jumper Settings Both Jumpers Definition Pins 1 2 Enable...

Страница 74: ...is 1 2 to enable the connection See the table on the right for jumper settings VGA Enable Jumper Settings Jumper Setting Definition 1 2 Enabled Default 2 3 Disabled BMC Enable Jumper JPB1 allows you to enable the embedded WPCM 450 BMC Baseboard Management Controller to provide IPMI 2 0 KVM support on the motherboard See the table on the right for jumper settings BMC Enable Jumper Settings Jumper S...

Страница 75: ...Flashing Quickly ACPI S1 State LAN 1 LAN 2 Link LED Left LED State LED Color Definition Off 10 Mbps 100 Mbps or No Connection Green 10 Gbps Amber 1 Gbps LAN 1 LAN 2 Activity LED Right LED State Color Status Definition Green Flashing Active Onboard Power LED An Onboard Power LED is located at DL4 on the motherboard When this LED is on the system is on Be sure to turn off the system and unplug the p...

Страница 76: ...ed in black are located on the motherboard I SATA ports are supported by the Intel PCH chip while S SATA ports are supported by SCU Storage Control Unit These ports provide serial link signal connections which are faster than the connections of Parallel ATA See the table on the right for pin definitions SAS2 Ports X9DAX 7F Only Eight Serial_Attached_SCSI Ports L SAS 0 3 L SAS 4 7 provide Serial_At...

Страница 77: ...ged with your serverboard Figure 5 12 Driver Tool Installation Display Screen Note Click the icons showing a hand writing on paper to view the readme files for each item Click the computer icons to the right of these items to install each item from top to the bottom one at a time After installing each item you must re boot the system before moving on to the next item on the list The bottom icon wi...

Страница 78: ...system information such as CPU temperature system voltages and fan status See the Figure below for a display of the Supero Doctor III interface Note The default User Name and Password for SuperDoctor III is ADMIN ADMIN Note When SuperDoctor III is first installed it adopts the temperature threshold settings that have been set in BIOS Any subsequent changes to these thresholds must be made within S...

Страница 79: ...aded from our Web Site at ftp ftp supermicro com utility Supero_Doctor_III You can also download the SDIII User s Guide at http www supermicro com PRODUCT Manuals SDIII UserGuide pdf For Linux we will recommend using Supero Doctor II Figure 5 14 Supero Doctor III Interface Display Screen Remote Control ...

Страница 80: ... battery must be replaced only with the same or an equivalent type recommended by the manufacturer CR2032 Dispose of used batteries according to the manufacturer s instructions Please handle used batteries carefully Do not damage the battery in any way a damaged battery may release hazardous materials into the environment Do not discard a used battery in the garbage or a public landfill Please com...

Страница 81: ...ing up your chassis Tools Required The only tool you will need to install components and perform maintenance is a Philips screwdriver Figure 6 1 Chassis Front and Rear Views Front Control Panel Front Lock Cover PCI Card Slots Power Supplies I O Shield Storage Module Figure 6 2 Chassis in Rack Mount Mode Review the warnings and precautions listed in the manual before setting up or servicing this ch...

Страница 82: ...als back into their antistatic bags when not in use For grounding purposes make sure your computer chassis provides excellent conductivity between the power supply the case the mounting fasteners and the serverboard 6 2 Control Panel The control panel located on the front of the chassis must be connected to the JF1 connector on the serverboard to provide you with system status indications A ribbon...

Страница 83: ... system fans mid system fans and rear system fans Replacing Mid System Fans FAN 0114L4 1 Determine which fan has failed Because the fans are hot swappable the chassis does not need to be powered down 2 Press the fan release tab and lift the failed fan from the chassis Mid fans must be pulled straight out of the chassis see Figure 6 3 Part numbers four fans are FAN 0114L4 3 Place the new fan into t...

Страница 84: ...6 4 SUPERSERVER 7047AX TRF 7047AX 72RF User s Manual Rear Fan Release Tab Figure 6 4 Rear System Chassis Fans Figure 6 3 Mid System Chassis Fans FAN 0082L4 FAN 0114L4 ...

Страница 85: ...power must be completely removed from the workstation before removing and replacing the power supply for whatever reason Replacing the Power Supply With a redundant power supply the system automatically switches to the second power supply if the first should fail Replacing the Power Supply 1 Power down the chassis and unplug the power cord If your chassis includes a redundant power supply at least...

Страница 86: ...d 8 pin serverboard cable 1 Serverboard Provides power to the serverboard CPU This cable has two black and two yellow wires 4 pin serverboard cable 1 Serverboard Provides power to PCI expansion card This cable has two black and two yellow wires 5 pin SMBus power cable small 1 Serverboard Allows the SM System Management bus to monitor power supply 2 pin INT cable 1 Serverboard Intrusion detection c...

Страница 87: ...tower mode and can be immediately used as workstation If the chassis is to be used in a rack the storage module must be rotated 90 degrees and the storage moudule cover must be replaced see Figure 6 7 This can be done before during or after setup It is not necessary to replace the storage module cover when the chassis is in the tower configuration Figure 6 7 Chassis in Rack Mount Mode Figure 6 8 C...

Страница 88: ...ule to any component in the chassis 3 Push the storage module release lever This lever unlocks the storage module see Figure 6 9 4 Grasp the external edges of the storage module and pull the unit from the chassis Storage Module Release Lever Storage Module Figure 6 9 Removing the Storage Module Rotating the Storage Module Use the procedure below to rotate the storage module for rack configurations...

Страница 89: ...igure 6 10 includes three full sized drive bays and the front LED panel The storage module can be configured in one of three ways Add up to three extra hard drives to the drive trays Add up to three peripheral drives CD ROM DVD ROM etc drive trays Add five hot swappable hard drives to the storage module This configuration requires a mobile rack More information on mobile rack installation can be f...

Страница 90: ...d drives to the drive carriers Adding Hard Drives to the Drive Carriers 1 Open the chassis cover 2 Locate the drive tray release tab for the slot you want to place the peripheral drive see Figure 6 11 3 Push the drive tray toward the front of the chassis Drive Tray Release Tabs Figure 6 11 Removing a Drive Carrier ...

Страница 91: ...s from the bottom 6 Slide the hard drive into the chassis until the carrier clicks into place 7 Repeat these steps for each hard drive carrier Warning Except for short periods of time swapping hard drives do not operate the workstation with the hard drive carriers removed Warning Enterprise level hard disk drives are recommended for use in Supermicro chassis and workstations For information on rec...

Страница 92: ...eral drive 3 Push the drive tray toward the front of the chassis 4 Remove the hard drive tray rails from the hard drive tray To do this you must remove two screws from each side see Figure 6 13 5 Attach the rails to a DVD ROM CD ROM floppy drive or other peripheral The rails should fit any standard sized peripherals 6 Slide the peripheral into the chassis until the tray clicks into place 7 Repeat ...

Страница 93: ...mote proper airflow for the drive bays Installing Hard Drives 1 Unlock and open the chassis cover 2 Press the release button to extend the drive tray handle see Figure 6 14 3 Using the handle pull the drive tray out by the handle The drive is hot swappable there are no cables to disconnect 4 Remove the screws holding the drive tray to the dummy drive Drive Tray Handle Release Button Figure 6 14 In...

Страница 94: ...ss the hard drive release button to extend the drive tray handle b Insert the hard drive into the chassis and close the handle to lock the hard drive into place see Figure 6 16 Figure 6 16 Installing a Hard Drive 5 Place a hard drive in the drive tray see Figure 6 15 6 Secure the hard drive to the tray using four screws Drive Tray SAS SATA Hard Drive ...

Страница 95: ...Chapter 6 Advanced Chassis Setup 6 15 Notes ...

Страница 96: ...t can be configured Grayed out options cannot be configured Options in blue can be configured by the user The right frame displays the key legend Above the key legend is an area reserved for informational text When an option is selected in the left frame it is highlighted in white Often informational text about the option will display on the right Note The AMI BIOS has default informational messag...

Страница 97: ...p utility From the main menu you can access the other setup screens An AMI BIOS identification string is displayed at the left bottom corner of the screen below the copyright message Warning Do not upgrade the BIOS unless your system has a BIOS related issue Flashing the wrong BIOS can cause irreparable damage to the sys tem In no event shall the manufacturer be liable for direct indirect special ...

Страница 98: ...0 12 2012 System Time This item displays the system time in HH MM SS format e g 15 32 52 Supermicro X9DAX SMC Version This item displays the SMC version of the BIOS ROM used in this system SMC Build Date This item displays the date that the BIOS ROM was built Memory Information Total Memory This displays the amount of memory that is available in the system ...

Страница 99: ...o instead of the normal POST messages The op tions are Enabled and Disabled AddOn ROM Display Mode Use this item to set the display mode for the Option ROM Select Keep Current to use the current AddOn ROM Display setting Select Force BIOS to use the Option ROM display mode set by the system BIOS The options are Force BIOS and Keep Current Bootup Num Lock Use this feature to set the Power on state ...

Страница 100: ...is feature is set to Instant Off the system will power off immediately as soon as the user presses the power button If this feature is set to 4 Seconds Override the system will power off when the user presses the power button for 4 seconds or longer The options are Instant Off and 4 Seconds Override Restore on AC Power Loss Use this feature to set the power state after a power outage Select Stay O...

Страница 101: ...to enhance CPU per formance The options are Enabled and Disabled Active Processor Cores Set to Enabled to use a processor s second core and above Please refer to Intel s website for more information The options are All 1 2 4 and 6 Limit CPUID Maximum This feature allows the user to set the maximum CPU ID value Enable this function to boot the legacy operating systems that cannot support processors...

Страница 102: ...rformance The options are Disabled and Enabled DCU IP Prefetcher Select Enabled for DCU Data Cache Unit IP Prefetcher support which will prefetch IP addresses to improve network connectivity and system performance The options are Enabled and Disabled Intel Virtualization Technology Available when supported by the CPU Select Enabled to support Intel Virtualization Technology which will allow one pl...

Страница 103: ...rocessor cores to run faster than marked frequency in specific conditions The options are Disabled and Enabled P State Coordination This feature allows the user to change the P State Power Performance State coordination type P State is also known as SpeedStep for Intel processors Select HW ALL to change the P State coordination type for hardware components only Select SW ALL to change the P State ...

Страница 104: ...Balanced Performance Balanced Energy and Energy Efficient Factory Long Duration Power Limit This item displays the power limit in watts set by the manufacturer during which long duration power is maintained Long Duration Power Limit This item displays the power limit in watts set by the user during which long duration power is maintained The default setting is 0 Factory Long Duration Maintained Th...

Страница 105: ...y leveraging CPU architectural improvements and freeing the system resource for other tasks The options are Disabled and Enabled DCA Support When set to Enabled this feature uses Intel s DCA Direct Cache Access Technology to improve data transfer efficiency The default is Enabled and can not be changed IOH 0 PCIe Port Bifurcation Control This submenu configures the following IO PCIe Port Bifurcati...

Страница 106: ... Generation 2 support for Port 3A Select GEN3 to enable PCI Exp Generation 3 support for Port 3A The options are GEN1 GEN2 and GEN3 IOH 1 PCIe Port Bifurcation Control This submenu configures the following IO PCIe Port Bifurcation Control settings for the PCIe ports to determine how the available PCI Express lanes will be distributed between the PCI Exp Root Ports IOU1 PCIe Port This feature allow...

Страница 107: ...4x4x8 x8x4x4 x8x8 and x16 Port 3A Link Speed Select GEN1 to enable PCI Exp Generation 1 support for Port 3A Select GEN2 to enable PCI Exp Generation 2 support for Port 3A Select GEN3 to enable PCI Exp Generation 3 support for Port 3A The options are GEN1 GEN2 and GEN3 Port 3C Link Speed Select GEN1 to enable PCI Exp Generation 1 support for Port 3C Select GEN2 to enable PCI Exp Generation 2 suppor...

Страница 108: ...t is selected all DIMMs are available to the operating system When Mirroring is selected the motherboard maintains two identical copies of all data in memory for data backup When Lockstep is selected the motherboard uses two areas of memory to run the same set of operations in parallel The options are Independent Mirroring Lock Step and Sparing DRAM RAPL BWLIMIT This item sets the limits on the av...

Страница 109: ... that allows the CPU to correct correctable memory errors detected on a memory module and send the correction to the requestor the original source When this item is set to Enabled the IO hub will read and write back one cache line every 16K cycles if there is no delay caused by internal processing By using this method roughly 64 GB of memory behind the IO hub will be scrubbed every day The options...

Страница 110: ...llows the user to configure the settings for the Intel PCH chip PCH Information This feature displays the following PCH information Name This item displays the name of the PCH chip Stepping This item displays the PCH stepping USB Devices This item displays the USB devices detected by the BIOS All USB Devices This feature enables all USB ports devices The options are Disabled and Enabled EHCI Contr...

Страница 111: ...led to enable support for Azalia High Definition Audio The options are Enabled and Disabled Azalia Internal HDMI Decode Select Enabled to enable support for Azalia High Definition Muliti Media Interface Decode The options are Enabled and Disabled SATA Configuration When this submenu is selected the AMI BIOS automatically detects the presence of IDE or SATA devices and displays the following items ...

Страница 112: ...urn the link to an active state when I O activity resumes The options are Enabled and Disabled Port 0 5 Hot Plug Select Enabled to enable hot plug support for a particular port which will allow the user to change a hardware component or device without shutting down the system The options are Enabled and Disabled Staggered Spin Up Select Enabled to enable Staggered Spin up support to prevent excess...

Страница 113: ...atency to 64 PCI clock cycles The options are 32 64 96 128 160 192 224 and 248 Above 4G Decoding Available if the system supports 64 bit PCI decoding Select Enabled to decode a PCI device that supports 64 bit in the space above 4G Address The options are Enabled and Disabled PERR Generation Select Enabled to allow a PCI device to generate a PERR number for a PCI Bus Signal Error Event The options ...

Страница 114: ...and Disabled Onboard LAN Option ROM Select Select iSCSI to use the iSCSI Option ROM to boot the computer using a network device Select PXE Preboot Execution Environment to use an PXE Option ROM to boot the computer using a network device The options are PXE and iSCSI Load Onboard LAN1 OPROM Load Onboard LAN2 OPROM Select Enabled to enable the onboard LAN1 LAN2 Option ROM This is to boot the comput...

Страница 115: ...nto one or more bytes The options are ANSI VT100 VT100 and VT UTF8 Bits Per second Use this feature to set the transmission speed for a serial port used in Console Redirection Make sure that the same speed is used in the host computer and the client computer A lower transmission speed may be required for long and busy lines The options are 9600 19200 38400 57600 and 115200 bits per second Data Bit...

Страница 116: ...e data displayed on a terminal and send it as text messages to a remote server The options are Disabled and Enabled Resolution 100x31 Select Enabled for extended terminal resolution support The options are Dis abled and Enabled Legacy OS Redirection Resolution Use this feature to select the number of rows and columns used in Console Redirection for legacy OS support The options are 80x24 and 80x25...

Страница 117: ...e Redirec tion Make sure that the same speed is used in the host computer and the client computer A lower transmission speed may be required for long and busy lines The options are 9600 19200 57600 and 115200 bits per second Flow Control This feature allows the user to set the flow control for Console Redirection to prevent data loss caused by buffer overflow Send a Stop signal to stop send ing da...

Страница 118: ...ons are Enabled and Disabled Trusted Computing Available when a TPM device is detected by the BIOS Configuration TPM Support Select Enabled on this item and enable the TPM jumper on the motherboard to enable TPM support to improve data integrity and network security The options are Enabled and Disabled TPM State Select Enabled to enable TPM security settings to improve data integrity and network s...

Страница 119: ...hnology CPU TXT Feature Chipset TXT Feature Intel TXT LT SX Configuration This feature displays the following TXT configuration setting TXT Support This item indicates if the Intel TXT support is enabled or disabled The default setting is Disabled Intel TXT LT SX Dependencies This feature displays the features that need to be enabled for the Intel Trusted Execution Technology to work properly in t...

Страница 120: ...ptions are Auto BCLK 101 BCLK102 BCLK 104 BCLK105 and BCLK 106 System Recovery Mode Use this feature to select the recovery mode setting When Auto is selected the BCLK will return to default settings after a system reset by the Watchdog Timer When Disabled is selected BIOS settings will not change on a system reset by the Watchdog Timer When Load Defaults is selected all overclocking settings will...

Страница 121: ...ons are Auto 5 6 7 8 9 10 11 12 13 14 15 16 17 and 18 tRAS Use this item to set the Ras Active Time value The options are Auto 12 13 14 15 16 17 and 18 tRRD Use this item to set the minimum tRDD Row Active to Row Active Delay value The options are Auto 19 23 27 32 36 and 41 tRRD Use this item to set the minimum tRDD Row Active to Row Active Delay value The options are Auto 4 5 6 7 and 8 tWR Use th...

Страница 122: ...agement BIOS Event Logging during system boot The options are Enabled and Disabled Runtime Error Logging Support Select Enabled to support Runtime Error Logging The options are Enabled and Disabled Memory Correctable Error Threshold This feature allows the user to enter the threshold value for correctable memory errors The default setting is 10 PCI Error Logging Support Select Enabled to support e...

Страница 123: ...othing and Erase Immediately SMBIOS Event Log Standard Settings Log System Boot Event Select Enabled to log system boot events The options are Disabled and Enabled MECI Multiple Event Count Increment Enter the increment value for the multiple event counter Enter a number between 1 to 255 The default setting is 1 METW Multiple Event Count Time Window This item allows the user to decide how long in ...

Страница 124: ...d in your system System Event Log Enabling Disabling Options SEL Components Select Enabled for all system event logging at bootup The options are Enabled and Disabled Erasing Settings Erase SEL Select Yes On next reset to erase all system event logs upon next system reboot Select Yes On every reset to erase all system event logs upon each system reboot Select No to keep all system event logs after...

Страница 125: ...ature allows the user to select the source of the IP address for this computer If Static is selected you will need to know the IP address of this computer and enter it to the system manually in the field If DHCP is selected the BIOS will search for a DHCP Dynamic Host Configuration Protocol server in the network that it is at tached to and request the next available IP address for this computer Th...

Страница 126: ...n 1 Boot Option 2 Boot Option 3 etc Use this feature to specify the sequence of boot device priority Network Devices USB Device BBS Priorities Hard Disk Drives The above options appear when detected by the BIOS Use these options to set the order of the legacy network USB and Hard Disk Drive devices detected by the motherboard Delete Boot Option This feature allows the user to select a boot device ...

Страница 127: ...this feature to set the Administrator Password which is required to enter the BIOS setup utility The length of the password should be from 3 characters to 20 characters long User Password Use this feature to set a User Password which is required to log into the system and to enter the BIOS setup utility The length of the password should be from 3 characters to 20 characters long ...

Страница 128: ... Reset When you have completed the system configuration changes select this option to save the changes and reboot the computer so that the new system configuration settings can take effect Select Save Changes and Exit and press Enter When the dialog box appears asking you if you want to exit the BIOS setup without sav ing select Yes to quit BIOS without saving the changes or select No to quit the ...

Страница 129: ...faults Select this feature and press Enter to save the current settings as the user s defaults When the dialog box appears asking you if you want to save values as user s defaults select Yes to save the current values as user s default settings or select No to keep the defaults previously saved as the user s defaults Restore User Defaults Select this feature and press Enter to load the user s defa...

Страница 130: ... possible repairs These fatal errors are usually communicated through a series of audible beeps The numbers on the fatal error list on the following page correspond to the number of beeps for the corresponding error All errors listed with the exception of Beep Code 8 are fatal errors Beep Code Error Message Description 1 beep Refresh Circuits have been reset Ready to power up 5 short beeps and 1 l...

Страница 131: ...A 2 SUPERSERVER 7047AX TRF 7047AX 72RF User s Manual Notes ...

Страница 132: ... ECC or up to 128 GB of Unbuffered UDIMM ECC Non ECC 1600 1333 1066 800 MHz 4 channel memory modules Note See the memory section in Chapter 5 for details SATA Controller Intel on chip controller for 10 SATA ports RAID 0 1 5 and 10 supported SAS Controller LSI 2208 Controller for 8 SAS ports RAID 0 1 5 10 50 and 60 supported Drive Bays Eight hot swap drive bays to house standard SATA drives Periphe...

Страница 133: ...Input Voltage 100 240V AC auto range Rated Input Current 11 5 5 5A max Rated Input Frequency 50 to 60 Hz Power Supply Rated Output Power 1280W Part PWS 1K28P 1R 80 Plus Platinum Certified Rated Output Voltages AC Input 1000W Output 100 140V 12 8A 50 60Hz 1280W Output 180 240V 8 6A 50 60Hz DC Output 1000W 12V 83A 5Vsb 4A 1280W 12V 106 7A 5Vsb 4A Operating Environment Operating Temperature 10º to 35...

Страница 134: ...61000 4 4 EN 61000 4 5 EN 61000 4 6 EN 61000 4 8 EN 61000 4 11 Safety CSA EN IEC UL 60950 1 Compliant UL or CSA Listed USA and Canada CE Marking Europe California Best Management Practices Regulations for Perchlorate Materials This Perchlorate warning applies only to products containing CR Manganese Dioxide Lithium coin cells Perchlorate Material special handling may apply See www dtsc ca gov haza...

Страница 135: ...nificant injury or loss of life or catastrophic property damage Accordingly Supermicro dis claims any and all liability and should buyer use or sell such products for use in such ultra hazardous applications it does so entirely at its own risk Furthermore buyer agrees to fully indemnify defend and hold Supermicro harmless for and against any and all claims demands actions litigation and proceeding...