2-4
S
UPER
S
ERVER 6026T-NTR+ User's Manual
2-4 Installing the System into a Rack
This section provides information on installing the SC825 chassis into a rack unit
with the quick-release rails provided. There are a variety of rack units on the market,
which may mean the assembly procedure will differ slightly. You should also refer to
the installation instructions that came with the rack unit you are using.
Note:
This rail will fi t a rack between 26" and 33.5" deep.
Separating the Sections of the Rack Rails
The chassis package includes two rail assemblies in the rack mounting kit. Each
assembly consists of two sections: an inner fi xed chassis rail that secures directly
to the server chassis and an outer fi xed rack rail that secures directly to the rack
itself.
Installing the Inner Rail Extension
The SC825 chassis includes a set of inner rails in two sections: inner rails and inner
rail extensions. The inner rails are pre-attached to the chassis, and do not interfere
with normal use of the chassis if you decide not to use a server rack. The inner rail
extension is attached to the inner rail to mount the chassis in the rack.
Installing the Inner Rails
Place the inner rail extensions on the side of the chassis aligning the hooks
1.
of the chassis with the rail extension holes. Make sure the extension faces
"outward" just like the pre-attached inner rail.
Slide the extension toward the front of the chassis.
2.
Secure the chassis with 2 screws as illustrated. Repeat steps for the other
3.
inner rail extension.
Содержание 6026T-NTR+
Страница 1: ... SUPERSERVER 6026T NTR SUPER USER S MANUAL 1 0b ...
Страница 5: ...Notes Preface v ...
Страница 23: ...Chapter 2 Server Installation 2 9 Figure 2 3 Accessing the Inside of the System ...
Страница 28: ...SUPERSERVER 6026T NTR User s Manual 3 4 Notes ...
Страница 96: ...A 2 SUPERSERVER 6026T NTR User s Manual Notes ...