Chapter 5: Advanced Serverboard Setup
5-17
Overheat (OH)/Fan Fail/PWR Fail/
UID LED
Connect an LED to pins 7 and 8 of
JF1 to provide advanced warning of
chassis overheating or fan failure.
These pins also work with the front
UID indicator, which will activate as
either a solid or flashing blue LED
depending on whether the LED was
activated via IPMI or the UID button.
Refer to the tables on the right for pin
definitions and status indicators.
Reset Button
The Reset Button connection is lo-
cated on pins 3 and 4 of JF1. Attach
it to the hardware reset switch on the
computer case. Refer to the table on
the right for pin definitions.
Power Button
The Power Button connection is
located on pins 1 and 2 of JF1. Mo-
mentarily contacting both pins will
power on/off the system. This button
can also be configured to function
as a suspend button (see the Power
Button Mode setting in BIOS). To turn
off the power when set to suspend
mode, depress the button for at least
4 seconds. Refer to the table on the
right for pin definitions.
Reset Button
Pin Definitions (JF1)
Pin# Definition
3
Reset
4
Ground
Power Fail LED
Pin Definitions (JF1)
Pin# Definition
5
Vcc
6
Ground
Power Button
Pin Definitions (JF1)
Pin# Definition
1
PW_ON
2
Ground
Power Fail LED
The Power Fail LED connection is
located on pins 5 and 6 of JF1. Refer
to the table on the right for pin defini
-
tions.
OH/Fan Fail/ PWR Fail/Blue_UID
LED Pin Definitions (JF1)
Pin# Definition
7
Blue_LED Cathode (UID)
8
OH/Fan Fail/PWR Fail/UID LED
OH/Fan Fail/PWR Fail LED Status
Pin 7 Pin 8 Red LED Blue LED
Low
High
On: OH/FF/Pwr Fail
(Solid On: OH
Fast Blinking: Fan Fail
Slow Blinking: Pwr Fail)
Off
High
Low
Off (System normal)
On
UID LED
High
High
Off
Off
Содержание 2027R-N3RF4+
Страница 1: ...SUPERSERVER 2027R N3RF4 2027R N3RFT SUPER USER S MANUAL 1 0 ...
Страница 5: ...v Preface Notes ...
Страница 14: ...1 6 SUPERSERVER 2027R N3RF4 2027R N3RFT User s Manual Notes ...
Страница 23: ...Chapter 2 Server Installation 2 9 1 4 1 4 Figure 2 5 Securing the Chassis to the Rack ...
Страница 24: ...2 10 SUPERSERVER 2027R N3RF4 2027R N3RFT User s Manual Notes ...
Страница 28: ...3 4 SUPERSERVER 2027R N3RF4 2027R N3RFT User s Manual Notes ...
Страница 62: ...5 30 SUPERSERVER 2027R N3RF4 2027R N3RFT User s Manual Notes ...
Страница 66: ...6 4 SUPERSERVER 2027R N3RF4 2027R N3RFT User s Manual Figure 6 3 Installing a Front System Fan ...
Страница 72: ...6 10 SUPERSERVER 2027R N3RF4 2027R N3RFT User s Manual Figure 6 7 Removing the Power Supply Release Tab ...
Страница 106: ...A 2 SUPERSERVER 2027R N3RF4 2027R N3RFT User s Manual Notes ...