![Supermicro X6DAL-G Скачать руководство пользователя страница 100](http://html1.mh-extra.com/html/supermicro/x6dal-g/x6dal-g_user-manual_1404175100.webp)
C-14
X6DAL-G/X6DAL-TG User's Manual
Rebuilding Arrays
*Note 1: Rebuilding applies to Fault Tolerant array (RAID 1) only.
If an array Build process (or initialization) is interrupted or critical with one
member missing, you must perform a Rebuild to get the array to Optimal
status. For a critical array Rebuild operation, the optimal drive is the source
drive.
*Note 2: If no spare array exists and a hard disk drive fails, you need to
create a spare before you can rebuild an array.
To Rebuild an array:
1 From the Main Menu, select Manage Arrays (as shown in the screen
below). From the List of Arrays, select the array you want to Rebuild.
2 Press Ctrl+R to Rebuild.