background image

USER’S MANUAL 

Revision 1.0

X11SSD-F

Содержание X11SSD-F

Страница 1: ...USER S MANUAL Revision 1 0 X11SSD F...

Страница 2: ...operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instruction manual may ca...

Страница 3: ...11SSD F motherboard to deliver a cost effective MicroCloud solution in a small form factor package Please note that this motherboard is intended to be installed and serviced by professional technician...

Страница 4: ...uter B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma s...

Страница 5: ...erature Control 18 System Resource Alert 18 1 5 ACPI Features 18 1 6 Power Supply 19 1 7 Super I O 19 1 8 Advanced Power Management 20 Intel Intelligent Power Node Manager IPNM 20 Management Engine ME...

Страница 6: ...7 Before Power On 47 No Power 47 No Video 48 System Boot Failure 48 Memory Errors 48 Losing the System s Setup Configuration 49 When the System Becomes Unstable 49 3 2 Technical Support Procedures 51...

Страница 7: ...Save Exit 90 Appendix A BIOS Codes Appendix B Software Installation B 1 Installing Software Programs 94 B 2 SuperDoctor 5 95 Appendix C Standardized Warning Statements Battery Handling 96 Product Disp...

Страница 8: ...ted is damaged or missing please contact your retailer 1 1 Checklist Important Links For your system to work properly please follow the links below to download all necessary drivers utilities and the...

Страница 9: ...herboard Image Note All graphics shown in this manual were based upon the latest PCB revision available at the time of publication of the manual The motherboard you received may or may not look exactl...

Страница 10: ...DESIGNED IN USA BAR CODE J4 BT1 SW1 S SGPIO1 LED2 A C LED1 A C JSTBY1 JBT1 FAN1 JTPM1 JBR1 JI2C2 JI2C1 J5 JPME2 JPB1 JPG1 JWD1 JVRM2 JVR1 JVRM1 LED3 A C DIMMA1 DIMMA2 DIMMB1 DIMMB2 SAS1 SAS0 I SATA2...

Страница 11: ...l C236 S SGPIO1 J4 JPG1 DIMMA1 DIMMB2 DIMMA2 DIMMB1 JWD1 JSTBY1 JBT1 BT1 J5 I SATA3 JSD1 JTPM1 UID JIPMB1 Quick Reference Notes See Chapter 2 for detailed information on jumpers I O ports and JF1 fron...

Страница 12: ...verheat PWR Fail Fan Fail LED Solid Red Overheat Blinking PWR Fail Fan Fail LED3 BMC Heartbeat LED Green Blinking BMC Normal Connector Description BT1 Onboard Battery FAN1 System Fan Header Reserved I...

Страница 13: ...at 1 2V Note 1 Memory speed support depends on the processors used in the system Note 2 For the latest CPU memory updates please refer to our website at http www supermicro com products motherboard Ch...

Страница 14: ...e ME with Client Platform Service System Health Monitoring Onboard voltage monitoring for 1 8V 3 3V 3 3V standby 5V 5V standby 12V VBAT CPU GPU Memory PCH Temp System Temp Memory Temp CPU 3 2 switchin...

Страница 15: ...chas sis and heatsink specifications for proper CPU TDP sizing Note 2 For IPMI configuration instructions please refer to the Embedded IPMI Con figuration User s Guide available at http www supermicr...

Страница 16: ...33 1866 1600MHz IMVP8 INTEL LGA1151 PCIe x8 SLOT PCIe3 0_x8 8 0GT s SVID IMVP8 DDR4 CHA DIMMA0 DDR4 CHB DIMMB0 2133 1866 1600MHz 8GT s x4 DMI SATA III 6Gb s 2 X SATA SAS BP Intel PCH H C236 Socket H4...

Страница 17: ...Gb s xHCI USB w SuperSpeed 3 0 System Management Bus SMBus Specification Version 2 0 Integrated Sensor Hub ISH The BMC supports remote management virtualization and the security package for enterpris...

Страница 18: ...ature Control System Health sensors in the BMC monitor the temperatures and voltage settings of onboard processors and the system in real time via the IPMI interface Whenever the temperature of the CP...

Страница 19: ...ry decode logic data rate selection a clock generator drive interface control logic and interrupt and DMA logic The wide range of functions integrated onto the Super I O greatly reduces the number of...

Страница 20: ...r maximum energy efficiency Although IPNM Specification Version 2 0 3 0 is supported by the BMC Baseboard Management Controller your system must also have IPNM compatible Management Engine ME firmware...

Страница 21: ...its components peripheral chips memory modules or gold contacts When handling chips or modules avoid touching their pins Put the motherboard and peripherals back into their antistatic bags when not i...

Страница 22: ...s of all the mounting holes for both the motherboard and the chassis match Although a chassis may have both plastic and metal mounting fasteners metal ones are highly recommended because they ground t...

Страница 23: ...therboard carefully to avoid damaging the motherboard components 4 Insert Pan head 6 screws into the mounting holes on the motherboard and the matching holes on the tray Use a Philips screwdriver to t...

Страница 24: ...uy a CPU separately make sure that you use an Intel certified multi directional heatsink only Make sure to install the motherboard into the chassis before you install the CPU heatsink When receiving a...

Страница 25: ...your thumb and your index finger to hold the CPU at the north center edge and the South center edge of the CPU 4 Align the CPU key that is the semi circle cutouts against the socket keys Once it is a...

Страница 26: ...your CPU Instead open the load plate again and double check that the CPU is aligned properly CPU properly installed Load lever locked into place 5 Do not rub the CPU against the surface or against any...

Страница 27: ...those on the Motherboard s and the Heatsink Bracket underneath 3 Screw in two diagonal screws i e the 1 and the 2 screws until just snug do not over tighten the screws to avoid possible damage to the...

Страница 28: ...rom the motherboard in the sequence as shown in the illustration below 2 Gently wriggle the heatsink to loosen it from the CPU Do not use excessive force when wriggling the heatsink 3 Once the CPU is...

Страница 29: ...f the same type and speed on the motherboard Mixing of memory modules of different types and speeds is not allowed DIMM Module Population Configuration For optimal memory performance follow the table...

Страница 30: ...rk properly please use memory modules of the same type and speed on the motherboard 2 Push the release tabs outwards on both ends of the DIMM slot to unlock it 3 Align the key of the DIMM module with...

Страница 31: ...ATA2 I SATA3 JIPMB1 JSMB1 CPU1 MICRO LP PCI E 3 0 X8 CPU1 SLOT1 PCI E 3 0 X8 KVM USB2 3 0 CPU Socket LGA1151 IPMI_LAN UID JSD1 SATA DOM POWER SATA DOM POWER Intel C236 2 5 Rear I O Ports See Figure 2...

Страница 32: ...therboard UID Button The Unit ID Button at UID is used in conjunction with the UID switch in front of the chassis and the UID LED located next to it When the switch is turned on the UID LED will turn...

Страница 33: ...C DIMMA1 DIMMA2 DIMMB1 DIMMB2 SAS1 SAS0 I SATA2 I SATA3 JIPMB1 JSMB1 CPU1 MICRO LP PCI E 3 0 X8 CPU1 SLOT1 PCI E 3 0 X8 KVM USB2 3 0 CPU Socket LGA1151 IPMI_LAN UID JSD1 SATA DOM POWER SATA DOM POWER...

Страница 34: ...This is a 4 pin fan headers pins 1 3 are backward compatible with traditional 3 pin fans The onboard fan speeds are controlled by Thermal Management via Hardware Monitoring in the BIOS When using The...

Страница 35: ...y device that supports encryption and authentication in hard drives It enables the motherboard to deny access if the TPM associated with the hard drive is not installed in the system Refer to the tabl...

Страница 36: ...s header for additional slave devices or sensors is located at JSMB1 Refer to the table below for pin definitions X11SSD F REV 1 00 DESIGNED IN USA BAR CODE J4 BT1 SW1 S SGPIO1 LED2 A C LED1 A C JSTBY...

Страница 37: ...rt Pin Definitions Pin Definition Pin Definition 1 P2V5SB 10 NC 2 TD0 11 DATA Out 3 TD0 12 Ground 4 TD1 13 Link 100 LED Green 3V3SB 5 TD1 14 Link 1000 LED Yellow 3V3SB 6 TD2 15 Ground 7 TD2 16 Ground...

Страница 38: ...M POWER SATA DOM POWER Intel C236 SATA and SAS Ports The X11SSD F has two SATA 3 0 ports I SATA2 and I SATA3 and two SAS 3 0 ports SAS0 and SAS1 that are supported by the Intel PCH C236 chipset SATA 3...

Страница 39: ...ns Connector Pins Jumper Setting 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clea...

Страница 40: ...ypass SPI flash security and force the system to use the Manufacturing Mode which will allow you to flash the system firmware from a host server to modify system settings Refer to the table below for...

Страница 41: ...x D for details VGA Enable Disable Jumper Settings Jumper Setting Definition Pins 1 2 Normal Default Pins 2 3 VGA Disable BIOS Recovery Jumper Settings Jumper Setting Definition Off Normal Default On...

Страница 42: ...s for VRM Jumpers JVRM1 and JVRM2 allow the BMC or the PCH to access CPU and memory VRM controllers Refer to the table below for jumper settings Watch Dog JWD1 controls the Watch Dog function Watch Do...

Страница 43: ...2 A C LED1 A C JSTBY1 JBT1 FAN1 JTPM1 JBR1 JI2C2 JI2C1 J5 JPME2 JPB1 JPG1 JWD1 JVRM2 JVR1 JVRM1 LED3 A C DIMMA1 DIMMA2 DIMMB1 DIMMB2 SAS1 SAS0 I SATA2 I SATA3 JIPMB1 JSMB1 CPU1 MICRO LP PCI E 3 0 X8 C...

Страница 44: ...Left Amber Solid 1 Gb s Green Solid 100 Mb s Activity Right Yellow Blinking Active 1 IPMI_LAN LED X11SSD F REV 1 00 DESIGNED IN USA BAR CODE J4 BT1 SW1 S SGPIO1 LED2 A C LED1 A C JSTBY1 JBT1 FAN1 JTP...

Страница 45: ...more information 1 Overheat PWR Fail Fan Fail LED 2 BMC Heartbeat LED BMC Heartbeat LED LED Settings LED Color Definition Green Blinking BMC Normal X11SSD F REV 1 00 DESIGNED IN USA BAR CODE J4 BT1 SW...

Страница 46: ...X8 CPU1 SLOT1 PCI E 3 0 X8 KVM USB2 3 0 CPU Socket LGA1151 IPMI_LAN UID JSD1 SATA DOM POWER SATA DOM POWER Intel C236 1 UID LED Indicator The UID LED Indicator located LED1 is next to the UID Button W...

Страница 47: ...Disconnect all cables from the motherboard including those for the keyboard and mouse 5 Remove all add on cards 6 Install a CPU a heatsink and connect the internal speaker and the power LED to the mo...

Страница 48: ...there are error beeps clear the CMOS settings by unplugging the power cord and contacting both pads on the CMOS Clear Jumper JBT1 Refer to chapter 2 2 Remove all components from the motherboard espec...

Страница 49: ...t http www supermicro com for memory and CPU support and updates 3 HDD support Make sure that all hard disk drives HDDs work properly Replace the bad HDDs with good ones 4 System cooling Check the sys...

Страница 50: ...ecessary remove a component in question from the chassis and test it in isolation to make sure that it works properly Replace a bad component with a good one 5 Check and change one component at a time...

Страница 51: ...in this chapter or see the FAQs on our website before contacting Technical Support 2 BIOS upgrades can be downloaded from our website Note Not all BIOS can be flashed depending on the modifications t...

Страница 52: ...re downloading You can choose from the zip file and the exe file If you choose the zip BIOS file please unzip the BIOS file onto a bootable USB device Run the batch file using the format FLASH BAT fil...

Страница 53: ...e the battery in any way a damaged battery may release hazardous materials into the environment Do not discard a used battery in the garbage or a public landfill Please comply with the regulations set...

Страница 54: ...tly displayed on the outside of the shipping carton and mailed prepaid or hand carried Shipping and handling charges will be applied for all orders that must be mailed when service is complete For fas...

Страница 55: ...c Each main BIOS menu option is described in this manual The Main BIOS screen has two main frames The left frame displays all the options that can be configured Grayed out options cannot be configured...

Страница 56: ...nd time Highlight System Date or System Time using the arrow keys Enter new values using the keyboard Press the Tab key or the arrow keys to move between fields The date must be entered in MM DD YYYY...

Страница 57: ...Chapter 4 BIOS 57 Memory Information Total Memory This item displays the total size of memory available in the system Memory Speed This item displays the memory speed...

Страница 58: ...feature to select the screen display between the POST messages and the OEM logo upon bootup Select Disabled to display the POST messages Select Enabled to display the OEM logo instead of the normal P...

Страница 59: ...stallation since the native XHCI driver support is unavailable Use a SATA optical drive as a USB drive and USB CD DVD drives are not supported Disable this feature after the XHCI driver has been insta...

Страница 60: ...y Type of CPU CPU Signature Microcode Patch Max CPU Speed Min CPU Speed CPU Speed Processor Cores Hyper Threading Technology Intel VT x Technology Intel SMX Technology 64 bit EIST Technology CPU C3 St...

Страница 61: ...isabled and Enabled Adjacent Cache Line Prefetch Available when supported by the CPU The CPU prefetches the cache line for 64 bytes if this feature is set to Disabled The CPU prefetches both cache lin...

Страница 62: ...ess or on your keyboard to change the value Enter 0 to use the manufacture default setting 2 Core Ratio Limit Override This increases multiplies 2 clock speeds in the CPU core in relation to the bus s...

Страница 63: ...le the Package C State un demotion The options are Disabled C1 C3 and C1 and C3 C State Pre Wake This feature allows the user to enable or disable the C State Pre Wake The options are Disabled and Ena...

Страница 64: ...SGX Use this feature to enable or disable the Intel Software Guard Extensions SGX SGX is a set of CPU instructions that increases software security The options are Disabled Enabled and Software Contr...

Страница 65: ...is feature to enable or disable DMI Virtual Channel 1 The options are Enabled and Disabled DMI VCm Control Use this feature to enable or disable the DMI Virtual Channel map The options are Enabled and...

Страница 66: ...e to set the upper limit on the power supplied by the PCIE slot Press or on your keyboard to change this value The default setting is 75 SLOT1 Slot Power Limit Scale Use this feature to select the sca...

Страница 67: ...will be programmed after OPROM If this item is set to Disabled the PCI E ASPM will be programmed before OPROM The options are Disabled and Enabled Memory Configuration The following memory informatio...

Страница 68: ...nt Use this feature to monitor the power consumption and temperature of the system to predict a thermal trend The options are Disabled and Enabled PCH IO Configuration The following PCH IO information...

Страница 69: ...rozen Mode The options are Enabled and Disabled If the item above SATA Mode Selection is set to RAID the following items will display SATA RAID Option ROM UEFI Driver Select UEFI to load the EFI drvie...

Страница 70: ...t Enabled to allow a PCI device to generate a PERR SERR number for a PCI Bus Signal Error Event The options are Enabled and Disabled Above 4G Decoding Available if the system supports 64 bit PCI decod...

Страница 71: ...ard to change the value The default setting is 1 Super IO Configuration The following Super IO information will display Super IO Chip Super IO Chip Logical Device s Configuration Serial Port 1 Configu...

Страница 72: ...erial port specified by the user Select Auto to allow the BIOS to automatically assign the base I O and IRQ address The options for Serial Port 2 are Auto IO 2F8h IRQ 3 IO 3F8h IRQ 3 4 5 6 7 9 10 11 1...

Страница 73: ...transmission speed for a serial port used in Console Redirection Make sure that the same speed is used in the host computer and the client computer A lower transmission speed may be required for long...

Страница 74: ...isabled and Enabled COM1 Legacy OS Redirection Resolution Use this feature to select the number of rows and columns used in Console Redirection for legacy OS support The options are 80x24 and 80x25 CO...

Страница 75: ...ts SOL Parity A parity bit can be sent along with regular data bits to detect data transmission errors Select Even if the parity bit is set to 0 and the number of 1 s in data bits is even Select Odd i...

Страница 76: ...le legacy Console Redirection after BIOS POST When set to Bootloader legacy Console Redirection is disabled before booting the OS When set to Always Enable legacy Console Redirection remains enabled w...

Страница 77: ...to stop sending data when the receiving buffer is full Send a Start signal to start sending data when the receiving buffer is empty The options are None Hardware RTS CTS and Software Xon Xoff Data Bi...

Страница 78: ...led and Enabled SHA256 PCR Bank Use this item to disable or enable the SHA256 Platform Configuration Register PCR bank for the installed TPM device The options are Disabled and Enabled TPM State This...

Страница 79: ...s that indicate the current TPM State TPM Enabled Status TPM Active Status TPM Owner Status TXT Support Intel TXT Trusted Execution Technology helps protect against software based attacks and ensures...

Страница 80: ...sing Settings Erase Event Log If No is selected data stored in the event log will not be erased Select Yes Next Reset data in the event log will be erased upon next system reboot Select Yes Every Rese...

Страница 81: ...plicate event must happen before the MECI counter is incremented This is a numeric value The default value is 1 METW The Multiple Event Time Window METW defines number of minutes must pass between dup...

Страница 82: ...firmware installed in your system System Event Log Enabling Disabling Options SEL Components Select Enabled for all system event logging at bootup The options are Enabled and Disabled Erasing Settings...

Страница 83: ...nd Yes Configuration Address Source This feature allows the user to select the source of the IP address for this computer If Static is selected you will need to know the IP address of this computer an...

Страница 84: ...omputer Mac addresses are 6 two digit hexadecimal numbers Gateway IP Address This item displays the Gateway IP address for this computer This should be in decimal and in dotted quad form i e 172 31 0...

Страница 85: ...tem to check for a password at bootup or upon entering the BIOS Setup utility The options are Setup and Always Administrator Password Press Enter to create a new or change an existing Administrator pa...

Страница 86: ...ptions are Yes and No Save All Secure Boot Variables This feature allows the user to decide if all secure boot variables should be saved Platform Key PK This feature allows the user to configure the s...

Страница 87: ...le The options are Yes and No Append Key Select Yes to add the DBX from the manufacturer s defaults to the existing DBX Select No to load the DBX from a file The options are Yes and No Authorized Time...

Страница 88: ...er Priorities This option prioritizes the order of bootable devices that the system to boot from Press Enter on each entry from top to bottom to select devices If the item above set to Legacy UEFI Dua...

Страница 89: ...Option 15 Delete Boot Option Use this feature to remove a pre defined boot device from which the system will boot during startup The settings are any pre defined boot device NETWORK Drive BBS Priorit...

Страница 90: ...Save Changes and Reset When you have completed the system configuration changes select this option to leave the BIOS setup utility and reboot the computer so the new system configuration parameters c...

Страница 91: ...t Save as User Defaults from the Exit menu and press Enter This enables the user to save any changes to the BIOS setup for future use Restore User Defaults To set this feature select Restore User Defa...

Страница 92: ...error messages normally appear on the screen Fatal errors are those which will not allow the system to continue the boot up procedure If a fatal error occurs you should consult with your system manufa...

Страница 93: ...support manuals AMI BIOS POST Codes User s Guide When BIOS performs the Power On Self Test it writes checkpoint codes to I O port 0080h If the computer cannot complete the boot process a diagnostic c...

Страница 94: ...may also use a utility to extract the ISO file if preferred After creating a CD DVD with the ISO files insert the disk into the CD DVD drive on your system and the display shown in Figure B 1 should a...

Страница 95: ...ctions in a command line or web based interface in Windows and Linux operating systems The program monitors system health information such as CPU temperature system voltages system power consumption f...

Страница 96: ...stalling or configuring components These warnings may also be found on our website at http www supermicro com about policies safety_information cfm Battery Handling Warnung Bei Einsetzen einer falsche...

Страница 97: ...evaar indien de batterij verkeerd vervangen wordt Vervang de batterij slechts met hetzelfde of een equivalent type die door de fabrikant aanbevolen wordt Gebruikte batterijen dienen overeenkomstig fab...

Страница 98: ...nacionales Attention La mise au rebut ou le recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Waa...

Страница 99: ...A UEFI BIOS flash chip consists of a recovery BIOS block and a main BIOS block a main BIOS image The boot block contains critical BIOS codes including memory detection and recovery codes for the user...

Страница 100: ...py the Super ROM binary image file into the disc Root Directory of a USB device or a writeable CD DVD Note If you cannot locate the Super ROM file in your driver disk visit our website at www supermic...

Страница 101: ...u want to start the BIOS recovery If you decide to proceed with BIOS recovery follow the procedures below 5 When the screen as shown above displays use the arrow keys to select the item Proceed with f...

Страница 102: ...the message that BIOS update has completed unplug the AC power cable from the power supply clear CMOS then plug the AC power cable in the power supply again to power on the system 10 Press Del contin...

Отзывы: