30
Super X11SDD-8C/18C-F User's Manual
JPWR1
JT
AG1
JRK1
JBT1
+
BT1
JTPM1
BMC_HB_LED1
J26
PRESS FIT
C
A
LED2
LED3
A C
FAN1
SW1
MH4
MH8
MH3
MH9
MH7
SAS1
SAS0
S-SGPIO1
MH5
MH6
MH2
MH1
JWD1
SRW10
SRW11
SRW12
SRW5
SRW6
SRW7
SRW8
SRW9
JKVM1
J3
J2
J20
X11SDD-8C-F
REV:1.02
DESIGNED IN USA
DIMMB1
DIMMA1
DIMME1 DIMMD1
CPU MICRO-LP
PCI-E 3.0 X8
M.2-H
M.2-H
CPU SLOT
PCI-E 3.0 X16
USB0/1
UID
CPU
S/N CODE
IPMI CODE
BIOS
LICENSE
S/N LABEL
JPME2
Headers
Fan Header
The X11SDD-8C/18C-F has one 4-pin fan headers (FAN1). This header is backwards-
compatible with the traditional 3-pin fans. However, fan speed control is available for 4-pin
fans only by Thermal Management via the IPMI 2.0 interface. Refer to the table below for
pin definitions.
Fan Header
Pin Definitions
Pin#
Definition
1
Ground (Black)
2
2.5A/+12V (Red)
3
Tachometer
4
PWM_Control
1
2
1. FAN1
2. SGPIO Header
SGPIO Header
One SGPIO (Serial General Purpose Input/Output) header is located on the motherboard.
S-SGPIO1 supports the Serial Link (SATA/SAS) interface. See the tables below for pin
definitions.
S-SGPIO Header
Pin Definitions
Pin#
Definition
Pin#
Definition
1
NC
2
NC
3
Ground
4
Data
5
Load
6
Ground
7
Clock
8
NC
Note:
NC = No Connection