Chapter 1: Introduction

Quick Reference Table

Jumper

Description

Default Setting

JBT1

CMOS Clear

Open (Normal)

JHD_AC1

AC97/High Definition Audio Enable

Off (HD Enabled)

JPAC1

Audio Enable

Pins 1-2 (Enabled)

JPME2

ME Manufacturing Mode

Pins 1-2 (Normal)

JPTG1

Onboard 10Gb LAN1/LAN2 Enable/Disable

Pins 1-2 (Enabled)

JVRM_SEL1

VRM_I2C Jumper

Pins 1-2 (Normal)

JWD1

Watch Dog Timer Reset

Pins 1-2 (Reset)

Connector

Description

AUDIO_FP

Front Panel Audio Header

BT1

Onboard Battery

COM1

COM Port (COM1) on the I/O Back Panel

COM2

COM Header

FAN1 ~ FAN6, FANA, 
FANB, FANC, FAND

System/CPU Fan Headers (FAN5: CPU1 Fan, FAN6: CPU2 Fan)

I-SATA0~3, I-SATA4~7

Intel PCH SATA 3.0 Ports (0~3, 4~7)

IPMI_LAN

Dedicated IPMI LAN Port

JF1

Front Control Panel Header

JIPMB1

4-pin BMC External I

2

C Header (for an IPMI card)

JL1 

Chassis Intrusion Header (

Note:

 Please connect a cable from the Chassis Intrusion header at JL1 

to the chassis to receive an alert via IPMI.)

JNCSI1

NC-SI Header for IPMI Support

JNVI2C1

NVMe SMBus (I

2

C) Headers used for PCIe hot-plug SMBus clock & data connections, and for 

the NVMe Add-on Card on PCI-E Slot9 (an SMCI-proprietary NVMe add-on card and cable are 
required; available for a Supermicro complete system only)

JNVI2C2

NVMe SMBus (I

2

C) Headers used for PCIe hot-plug SMBus clock & data connections, and for 

the NVMe Add-on Card on PCI-E Slot10 (an SMCI-proprietary NVMe add-on card and cable are 
required; available for a Supermicro complete system only)

JPI2C1

Power Supply SMBus I

2

C Header

JPWR1

24-pin ATX Power Connector

JPWR2, JPWR3

12V 8-pin CPU Power Connectors (To provide alternative power for special enclosure when the 
24-pin ATX power is not in use.)

JPWR4

12V 4-pin Power Connector

(VROC) JRK1

Intel VROC RAID Key Header for NVMe SSDs 

Note 1:

 Intel VMD is supported by CPU1 SLOT9 and CPU2 SLOT10. 

Note 2:

 After you’ve enabled VMD in the BIOS on a PCIe slot of your choice, this PCIe 

slot will be dedicated for VMD use only, and it will no longer support any PCIe device. 
To re-activate this slot for PCIe use, please disable VMD in the BIOS.

Содержание X11DPG-QT

Страница 1: ...USER S MANUAL Revision 1 1a X11DPG QT...

Страница 2: ...n industrial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instruction manual may cause harmful i...

Страница 3: ...tation platforms Please note that this motherboard is intended to be installed and serviced by professional technicians only For processor memory updates please refer to our website at http www superm...

Страница 4: ...4 Appendix F describes secure boot settings Appendix G states iSCSI settings Appendix H provides Network Interface Card NIC settings Super X11DPG QT User s Manual...

Страница 5: ...puter B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma...

Страница 6: ...lation 26 Intel Xeon Scalable SP and 2nd Gen Intel Xeon Scalable SP Processors 26 Overview of the Processor Socket Assembly 27 Overview of the Processor Heatsink Module PHM 28 Attaching the Processor...

Страница 7: ...1 2 6 Front Control Panel 45 2 7 Connectors 49 Power Connections 49 Headers 50 2 8 Jumper Settings 60 How Jumpers Work 60 2 9 LED Indicators 65 Chapter 3 Troubleshooting 3 1 Troubleshooting Procedures...

Страница 8: ...USB Device 183 Appendix E Configuring VROC RAID Settings E 1 All Intel VMD Controllers Menu 187 E 2 Configuring RAID Settings 191 E 3 Use of Journaling Drive 207 Appendix F Secure Boot Settings F 1 Bo...

Страница 9: ...inks below to download all necessary drivers utilities and the user s manual for your server Supermicro product manuals http www supermicro com support manuals Product drivers and utilities https www...

Страница 10: ...T Motherboard Image Note All graphics shown in this manual were based upon the latest PCB revision available at the time of publication of the manual The motherboard you received may or may not look e...

Страница 11: ...E9 CPU2 SLOT8 PCI E 3 0 x16 JNVI2C2 JNVI2C1 CPU1 SLOT9 PCI E 3 0 x16 JPCIE6 JPCIE4 CPU2 SLOT6 PCI E 3 0 x16 CPU1 SLOT4 PCI E 3 0 x16 JPCIE2 CPU1 SLOT2 PCI E 3 0 x16 JGPIO_P2 CPU2 HSSI GPIO JGPIO_P1 CP...

Страница 12: ...C BAR CODE BIOS LICENSE CPU1 CPU2 PCH BMC LAN CTRL FAN1 FAN2 FANA FANB JL1 JPI2C1 FAN6 COM1 SP1 BT1 USB 0 1 IPMI_LAN JUIDB1 LEDM1 LED2 VGA P1 DIMMA1 P1 DIMMA2 P1 DIMMC1 P1 DIMMB1 P1 DIMME1 P1 DIMMF1 P...

Страница 13: ...rt via IPMI JNCSI1 NC SI Header for IPMI Support JNVI2C1 NVMe SMBus I2 C Headers used for PCIe hot plug SMBus clock data connections and for the NVMe Add on Card on PCI E Slot9 an SMCI proprietary NVM...

Страница 14: ...S SATA5 SATA 3 0 Ports with Power pin Built in w support of SuperDOM Device On Module S SGPIO Serial Link General Purpose I O Header SP1 Internal Speaker Buzzer USB0 USB1 Back Panel USB 2 0 Ports USB...

Страница 15: ...ly 3 Support for 2933 MHz memory is dependent on the CPU SKU 4 Refer to Chapter 2 for detailed DDR4 memory support list DIMM Size Up to 256GB at 1 2V Note 1 Memory speed support depends on the process...

Страница 16: ...ns on the motherboard for front access USB2 USB3 BIOS 32MB SPI AMI BIOS SM Flash UEFI BIOS ACPI 3 0 4 0 USB keyboard Plug and Play PnP SPI dual quad speed support riser card auto detection support and...

Страница 17: ...y Dimensions 15 12 L x 13 2 W 384 mm x 335 3 mm Note 1 The CPU maximum thermal design power TDP is subject to chassis and heatsink cooling restrictions For proper thermal management please check the c...

Страница 18: ...IMM REAR USB2 0 port 4 5 USB2 0 DDR4 DIMM 1 B DDR4 DIMM x16 x16 DMI PET 4 5 6 7 PHY RTL8211E USB2 0 7 ESPI PET9 1 DDR4 DIMM DDR4 DIMM DDR4 DIMM sSATA Gen3 4 5 BMC REAR USB3 0 AST2500 DDR4 DIMM A DDR4...

Страница 19: ...gement Engine ME Support of SMBus speeds of up to 400KHz for BMC connectivity Improved I O capabilities to high storage capacity configurations SPI enhancements Intel Node Manager 4 0 for advanced pow...

Страница 20: ...upport for 2933MHz memory and DCPMM memory is dependent on the CPU SKU 1 3 Special Features This section describes the health monitoring features of the X11DPG QT motherboard The motherboard has an on...

Страница 21: ...lert This feature is available when used with SuperDoctor 5 SuperDoctor 5 is used to notify the user of certain system events For example you can configure SuperDoctor 5 to provide you with warnings w...

Страница 22: ...stem must also have IPNM compatible Management Engine ME firmware installed to use this feature Note Support for IPNM 2 0 3 0 support is dependent on the power supply used in the system Management Eng...

Страница 23: ...do not touch its components peripheral chips memory modules or gold contacts When handling chips or modules avoid touching their pins Put the motherboard and peripherals back into their antistatic ba...

Страница 24: ...ng fasteners metal ones are highly recommended because they ground the motherboard to the chassis Make sure that the metal standoffs click in or are screwed in tightly Location of Mounting Holes Notes...

Страница 25: ...ffs in the chassis as needed 5 Install the motherboard into the chassis carefully to avoid damaging other motherboard components 6 Using the Phillips screwdriver insert a Phillips head 6 screw into a...

Страница 26: ...ocessor Heatsink Module PHM and then install the entire PHM into the CPU socket When you receive a motherboard without a processor pre installed make sure that the plastic CPU socket cap is in place a...

Страница 27: ...n the CPU is not in stalled 2 Narrow processor clip the plastic processor package carrier used for the CPU Overview of the Processor Socket Assembly The processor socket assembly contains 1 Intel Xeon...

Страница 28: ...3 Intel Processor Processor Heatsink Module PHM Overview of the Processor Heatsink Module PHM The Processor Heatsink Module PHM contains 1 a heatsink 2 a narrow processor clip and 3 Intel Xeon Scalabl...

Страница 29: ...ip by sliding notch B of the CPU into notch B of the processor clip and sliding notch C of the CPU into notch C of the processor clip 4 Examine all corners of the CPU to ensure that it is properly sea...

Страница 30: ...e a larger hole and plastic mounting clicks located next to the hollow triangle Also locate another set of mounting clicks and Heatsink Upside Down Non Fabric CPU and Processor Clip Upside Down C D d...

Страница 31: ...omponents are pre installed on the motherboard before shipping CPU Socket w Dust Cover On Dusk Cover CPU Socket Removing the Dust Cover from the CPU Socket Remove the dust cover from the CPU socket ex...

Страница 32: ...ht side up and you will see a triangle marked on the processor clip at the same corner of hollow triangle 3 Carefully align pin 1 the triangle on the PHM against pin 1 the triangle on the CPU socket 4...

Страница 33: ...processor heatsink module PHM unplug power cord from the power outlet 1 Using a T30 Torx bit screwdriver turn the screws on the PHM counterclockwise to loosen them from the socket starting with screw...

Страница 34: ...oard will affect memory bandwidth and performance 5 Unbalanced memory configuration is not recommended 6 Support for 2933MHz memory is dependent on the CPU SKU 7 16Gb based memory modules are supporte...

Страница 35: ...Speed MT s Voltage V Slots Per Channel SPC and DIMMs Per Chan nel DPC 1 Slot Per Channel 2 Slots Per Channel DRAM Density 1DPC 1 DIMM Per Channel 1DPC 1 DIMM Per Channel 2DPC 2 DIMM Per Channel 4Gb 8...

Страница 36: ...follow the instructions listed in the tables below when populating memory modules Key Parameters for DIMM Configuration DIMM Mixing Guidelines General DIMM Mixing Guidelines DIMM Mixing Rules All DIM...

Страница 37: ...1 P1 DIMMA1 P1 DIMMA2 P1 DIMMD1 P1 DIMME1 P1 DIMMF1 1 CPU 8 DIMMs Unbalanced not recommended CPU1 P1 DIMMC1 P1 DIMMB1 P1 DIMMA1 P1 DIMMA2 P1 DIMMD2 P1 DIMMD1 P1 DIMME1 P1 DIMMF1 When 2 CPUs are used M...

Страница 38: ...1 B1 C1 144GB 96GB A1 B1 C1 D1 192GB 128GB A1 B1 C1 D1 E1 240GB 160GB A1 B1 C1 D1 E1 F1 288GB 192GB A1 A2 B1 C1 D1 D2 E1 F1 416GB 320GB Dual Rank Memory Rank Sparing 16GB DIMM Memory Population Total...

Страница 39: ...M3 RDIMM 3DS RDIMM LRDIMM Note DDR4 single rank x8 is not available for DCPMM Memory Mode or App Direct Mode Legend for the first two tables above Capacity DCPMM Any Capacity Uniformly for all channel...

Страница 40: ...the slot 5 Use two thumbs together to press the notches on both ends of the module straight down into the slot until the module snaps into place 6 Press the release tabs to the lock positions to secu...

Страница 41: ...Ports See Figure 2 2 below for the locations and descriptions of the various I O ports on the rear of the motherboard Figure 2 2 I O Port Locations and Definitions Rear I O Ports Description Descripti...

Страница 42: ...REV 1 10A IPMI CODE MAC CODE SAN MAC BAR CODE BIOS LICENSE CPU1 CPU2 JBT1 PCH BT1 BMC VGA COM1 USB 0 1 IPMI_LAN USB 4 5 3 0 LAN 1 LAN 2 FAN 3 FAN 4 FAN 6 FAN 1 FAN 5 FAN 2 FAN A FAN B P2 DIMMD2 P2 DIM...

Страница 43: ..._SEL1 JWD1 JSEN1 JSTBY1 I SATA0 3 I SATA4 7 USB 6 7 3 0 USB 2 3 S SATA4 S SATA5 USB8 3 0 SP1 M 2 CONNECTOR JSD1 JSD2 S SGPIO JL1 FAN C FAN D 1 Front Panel USB 3 0 Pin Definitions Pin Definition Pin De...

Страница 44: ...lease refer to the IPMI User s Guide posted on our website at http www supermicro com UID Switch Pin Definitions Pin Definition 1 Ground 2 Ground 3 Button In 4 Button In UID LED Pin Definitions Color...

Страница 45: ...UID LED LEDM1 JPWR1 JPWR2 JPWR3 LAN CTRL P1 DIMMF1 P1 DIMME1 P1 DIMMD1 P1 DIMMD2 P2 DIMMC1 P2 DIMMB1 P2 DIMMA1 P2 DIMMA2 JNCSI1 JTBT1 JPCIE11 JPCIE10 CPU2 SLOT11 PCI E 3 0 x4 IN x8 CPU2 SLOT10 PCI E 3...

Страница 46: ...DD LED The HDD LED connection is located on pins 13 and 14 of JF1 Attach a cable here to indicate the status of HDD related activities including IDE SATA activities See the table below for pin definit...

Страница 47: ...tion 5 3 3V 6 PWR Supply Fail Information LED UID OH PWR Fail Fan Fail LED Pin Definitions Pin 7 Pin 8 of JF1 Status Description Solid red An overheat condition has occurred This may be caused by cabl...

Страница 48: ...ton can also be configured to function as a suspend button with a setting in the BIOS see Chapter 4 To turn off the power in the suspend mode press the button for at least 4 seconds Refer to the table...

Страница 49: ...1DPG QT DESIGNED IN USA REV 1 10A IPMI CODE MAC CODE SAN MAC BAR CODE BIOS LICENSE CPU1 CPU2 JBT1 PCH BT1 BMC VGA COM1 USB 0 1 IPMI_LAN USB 4 5 3 0 LAN 1 LAN 2 FAN 3 FAN 4 FAN 6 FAN 1 FAN 5 FAN 2 FAN...

Страница 50: ...WR JF1 JHD_AC1 AUDIO_FP JSPDIF_IN1 JPAC1 JPME2 JTPM1 COM2 JPTG1 JRK1 JIPMB1 JVRM_SEL1 JWD1 JSEN1 JSTBY1 I SATA0 3 I SATA4 7 USB 6 7 3 0 USB 2 3 S SATA4 S SATA5 USB8 3 0 SP1 M 2 CONNECTOR JSD1 JSD2 S S...

Страница 51: ...DE MAC CODE SAN MAC BAR CODE BIOS LICENSE CPU1 CPU2 JBT1 PCH BT1 BMC VGA COM1 USB 0 1 IPMI_LAN USB 4 5 3 0 LAN 1 LAN 2 FAN 3 FAN 4 FAN 6 FAN 1 FAN 5 FAN 2 FAN A FAN B P2 DIMMD2 P2 DIMMD1 P2 DIMME1 P2...

Страница 52: ...1 LAN 2 FAN 3 FAN 4 FAN 6 FAN 1 FAN 5 FAN 2 FAN A FAN B P2 DIMMD2 P2 DIMMD1 P2 DIMME1 P2 DIMMF1 P1 DIMMA2 P1 DIMMA1 P1 DIMMB1 P1 DIMMC1 JUIDB1 UID LED2 UID LED LEDM1 JPWR1 JPWR2 JPWR3 LAN CTRL P1 DIM...

Страница 53: ...PWR3 LAN CTRL P1 DIMMF1 P1 DIMME1 P1 DIMMD1 P1 DIMMD2 P2 DIMMC1 P2 DIMMB1 P2 DIMMA1 P2 DIMMA2 JNCSI1 JTBT1 JPCIE11 JPCIE10 CPU2 SLOT11 PCI E 3 0 x4 IN x8 CPU2 SLOT10 PCI E 3 0 x16 JPCIE8 JPCIE9 CPU2 S...

Страница 54: ...SATA5 X11DPG QT DESIGNED IN USA REV 1 10A IPMI CODE MAC CODE SAN MAC BAR CODE BIOS LICENSE CPU1 CPU2 JBT1 PCH BT1 BMC VGA COM1 USB 0 1 IPMI_LAN USB 4 5 3 0 LAN 1 LAN 2 FAN 3 FAN 4 FAN 6 FAN 1 FAN 5 F...

Страница 55: ...R4 LEDPWR JF1 JHD_AC1 AUDIO_FP JSPDIF_IN1 JPAC1 JPME2 JTPM1 COM2 JPTG1 JRK1 JIPMB1 JVRM_SEL1 JWD1 JSEN1 JSTBY1 I SATA0 3 I SATA4 7 USB 6 7 3 0 USB 2 3 S SATA4 S SATA5 USB8 3 0 SP1 M 2 CONNECTOR JSD1 J...

Страница 56: ...1 JPWR4 LEDPWR JF1 JHD_AC1 AUDIO_FP JSPDIF_IN1 JPAC1 JPME2 JTPM1 COM2 JPTG1 JRK1 JIPMB1 JVRM_SEL1 JWD1 JSEN1 JSTBY1 I SATA0 3 I SATA4 7 USB 6 7 3 0 USB 2 3 S SATA4 S SATA5 USB8 3 0 SP1 M 2 CONNECTOR J...

Страница 57: ...1 SLOT9 PCI E 3 0 x16 JPCIE6 JPCIE4 CPU2 SLOT6 PCI E 3 0 x16 CPU1 SLOT4 PCI E 3 0 x16 JPCIE2 CPU1 SLOT2 PCI E 3 0 x16 JGPIO_P2 CPU2 HSSI GPIO JGPIO_P1 CPU1 HSSI GPIO S UM12 JPI2C1 JPWR4 LEDPWR JF1 JHD...

Страница 58: ...I SATA0 3 I SATA4 7 USB 6 7 3 0 USB 2 3 S SATA4 S SATA5 USB8 3 0 SP1 M 2 CONNECTOR JSD1 JSD2 S SGPIO JL1 FAN C FAN D 1 NC SI Header for IPMI Support JNCSI1 1 NC SI Header for IPMI Support A Network C...

Страница 59: ...LEDM1 JPWR1 JPWR2 JPWR3 LAN CTRL P1 DIMMF1 P1 DIMME1 P1 DIMMD1 P1 DIMMD2 P2 DIMMC1 P2 DIMMB1 P2 DIMMA1 P2 DIMMA2 JNCSI1 JTBT1 JPCIE11 JPCIE10 CPU2 SLOT11 PCI E 3 0 x4 IN x8 CPU2 SLOT10 PCI E 3 0 x16 J...

Страница 60: ...pins Connector Pins Jumper Setting 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally cl...

Страница 61: ...0 x16 CPU1 SLOT4 PCI E 3 0 x16 JPCIE2 CPU1 SLOT2 PCI E 3 0 x16 JGPIO_P2 CPU2 HSSI GPIO JGPIO_P1 CPU1 HSSI GPIO S UM12 JPI2C1 JPWR4 LEDPWR JF1 JHD_AC1 AUDIO_FP JSPDIF_IN1 JPAC1 JPME2 JTPM1 COM2 JPTG1 J...

Страница 62: ...CPU1 CPU2 JBT1 PCH BT1 BMC VGA COM1 USB 0 1 IPMI_LAN USB 4 5 3 0 LAN 1 LAN 2 FAN 3 FAN 4 FAN 6 FAN 1 FAN 5 FAN 2 FAN A FAN B P2 DIMMD2 P2 DIMMD1 P2 DIMME1 P2 DIMMF1 P1 DIMMA2 P1 DIMMA1 P1 DIMMB1 P1 DI...

Страница 63: ...EDM1 JPWR1 JPWR2 JPWR3 LAN CTRL P1 DIMMF1 P1 DIMME1 P1 DIMMD1 P1 DIMMD2 P2 DIMMC1 P2 DIMMB1 P2 DIMMA1 P2 DIMMA2 JNCSI1 JTBT1 JPCIE11 JPCIE10 CPU2 SLOT11 PCI E 3 0 x4 IN x8 CPU2 SLOT10 PCI E 3 0 x16 JP...

Страница 64: ...PCI E 3 0 x4 IN x8 CPU2 SLOT10 PCI E 3 0 x16 JPCIE8 JPCIE9 CPU2 SLOT8 PCI E 3 0 x16 JNVI2C2 JNVI2C1 CPU1 SLOT9 PCI E 3 0 x16 JPCIE6 JPCIE4 CPU2 SLOT6 PCI E 3 0 x16 CPU1 SLOT4 PCI E 3 0 x16 JPCIE2 CPU...

Страница 65: ...ONNECTOR JSD1 JSD2 S SGPIO JL1 FAN C FAN D 2 9 LED Indicators IPMI Dedicated LAN LEDs A dedicated IPMI LAN is also included on the motherboard The amber LED on the right of the IPMI LAN port indicates...

Страница 66: ...n Blinking BMC Normal 1 Onboard Power LED 2 BMC Heartbeat LED 3 UID LED X11DPG QT DESIGNED IN USA REV 1 10A IPMI CODE MAC CODE SAN MAC BAR CODE BIOS LICENSE CPU1 CPU2 JBT1 PCH BT1 BMC VGA COM1 USB 0 1...

Страница 67: ...Disconnect all cables from the motherboard including those for the keyboard and mouse 5 Remove all add on cards 6 Install a CPU a heatsink and connect the internal speaker and the power LED to the mo...

Страница 68: ...the power cord and contacting both pads on the CMOS Clear Jumper JBT1 Refer to chapter 2 2 Remove all components from the motherboard especially the DIMM modules Make sure that system power is on and...

Страница 69: ...website at http www supermicro com for memory and CPU support and updates 3 HDD support Make sure that all hard disk drives HDDs work properly Replace the bad HDDs with good ones 4 System cooling Chec...

Страница 70: ...f necessary remove a component in question from the chassis and test it in isolation to make sure that it works properly Replace a bad component with a good one 5 Check and change one component at a t...

Страница 71: ...in this chapter or see the FAQs on our website before contacting Technical Support 2 BIOS upgrades can be downloaded from our website Note Not all BIOS can be flashed depending on the modifications t...

Страница 72: ...ged battery may release hazardous materials into the environment Do not discard a used battery in the garbage or a public landfill Please comply with the regulations set up by your local hazardous was...

Страница 73: ...s during memory count the first screen that appears when the system is turned on the momentary on off switch must be held for more than four seconds to shut down the system This feature is required to...

Страница 74: ...name 4 The FLASH NSH script will compare the Flash Descriptor Table FDT code in the new BIOS with the existing one in the motherboard a If a different FDT is found A new file STARTUP NSH will be creat...

Страница 75: ...ly displayed on the outside of the shipping carton and mailed prepaid or hand carried Shipping and handling charges will be applied for all orders that must be mailed when service is complete For fast...

Страница 76: ...2 etc Each main BIOS menu option is described in this manual The Main BIOS screen has two main frames The left frame displays all the options that can be configured Grayed out options cannot be config...

Страница 77: ...ys Enter new values using the keyboard Press the Tab key or the arrow keys to move between fields The date must be entered in MM DD YYYY format The time is entered in HH MM SS format Note The time is...

Страница 78: ...Super X11DPG QT User s Manual 78 Memory Information Total Memory This feature displays the total size of memory available in the system...

Страница 79: ...is feature to select the screen display between the POST messages and the OEM logo upon bootup Select Disabled to display the POST messages Select Enabled to display the OEM logo instead of the normal...

Страница 80: ...egacy boot device after an initial boot failure The options are Disabled Legacy Boot and EFI Boot Install Windows 7 USB support Enable this feature to use the USB keyboard and mouse during the Windows...

Страница 81: ...voltage control during processor idle states Select Enabled to decrease the system power by throttling CPU frequency when one power supply is failed The options are Disabled and Enabled CPU Configura...

Страница 82: ...te for detailed information PPIN Control Select Unlock Enable to use the Protected Processor Inventory Number PPIN in the system The options are Unlock Disable and Unlock Enable Hardware Prefetcher Av...

Страница 83: ...is set to Enable Select Enable to allow the BIOS to configure high priority CPU cores as Prioritized Base Frequency PBF so that software programs do not have to configure the PBF Prioritized Base Freq...

Страница 84: ...lock cycle and voltage during a Halt state The options are Disable and Enable Package C State Control Package C State This feature allows the user to set the limit on the C State package register The...

Страница 85: ...ry Cache IODC support The options are Dis able Auto Enable for Remote InvItoM Hybrid Push InvItoM AllocFlow Enable for Re mote InvItoM Hybrid AllocNonAlloc and Enable for Remote InvItoM and Remote WVi...

Страница 86: ...s are Auto Disable and Enable Enable ADR Select Enable for ADR Automatic Diagnostic Repository support to enhance memory performance The options are Disable and Enable Refresh Options Use this feature...

Страница 87: ...constructed when one of the memory devices fails on a DIMM Use this feature to enable the SDDC support The options are Disable and Enable ADDDC Sparing Adaptive Double Device Data Correction ADDDC Spa...

Страница 88: ...Bifurcation setting for a PCIe port specified by the user The options are x4x4x4x4 x4x4x8 x8x4x4 x8x8 x16 and Auto CPU1 SLOT2 PCI E 3 0 x16 Link Speed Use this feature to select the link speed for the...

Страница 89: ...t the maximum payload value for a PCIe device to enhance system performance The options are 128B 256B and Auto CPU1 SLOT9 PCI E 3 0 x16 Link Speed Use this feature to select the link speed for the PCI...

Страница 90: ...for the PCIe port The options are Auto Gen 1 2 5 GT s Gen 2 5 GT s and Gen 3 8 GT s PCI E Port Link Status PCI E Port Link Max PCI E Port Link Speed PCI E Port Clocking The options are Distinct and Co...

Страница 91: ...ptions are 128B 256B and Auto CPU2 SLOT10 PCI E 3 0 x16 Link Speed Use this feature to select the link speed for the PCIe port The options are Auto Gen 1 2 5 GT s Gen 2 5 GT s and Gen 3 8 GT s PCI E P...

Страница 92: ...ort for Direct I O VT d support by reporting the I O device assignments to the VMM Virtual Machine Monitor through the DMAR ACPI Tables This feature offers fully protected I O resource sharing across...

Страница 93: ...eature Intel VMD for Volume Management Device is set to Enable the following features will be available CPU1 SLOT2 PCI E 3 0 x16 VMD Available when the device is detected by the system Select Enable t...

Страница 94: ...to enable the hot plug support for PCIe root ports 3A 3D The op tions are Disable and Enable Intel VMD for Volume Management Device on CPU2 VMD Config for PStack0 Intel VMD for Volume Management Devic...

Страница 95: ...e Technology for this stack The options are Disable and Enable If the feature Intel VMD for Volume Management Device is set to Enable the following features will be available CPU2 SLOT10 PCI E 3 0 x16...

Страница 96: ...60h 64h emulation support which will provide complete legacy USB keyboard support for the operating systems that do not support legacy USB devices The options are Disabled and Enabled Server ME Config...

Страница 97: ...ed by the user The options are Disable and Enable Spin Up Device SATA Port 0 Port 7 On an edge detect from 0 to 1 set this feature to allow the PCH to initialize the device The options are Disable and...

Страница 98: ...specified by the user should be connected to a Solid State drive or a Hard Disk Drive The options are Hard Disk Drive and Solid State Drive PCH sSATA Configuration sSATA Controller This feature enabl...

Страница 99: ...ort specified by the user should be connected to a Solid State drive or a Hard Disk Drive The options are Hard Disk Drive and Solid State Drive If the feature Configure SATA as is set to RAID the foll...

Страница 100: ...bove 4G Address The options are Disabled and Enabled SR IOV Support Use this feature to enable or disable Single Root IO Virtualization support The options are Disabled and Enabled MMIO High Base Use...

Страница 101: ...lot Legacy to activate the slot in legacy mode and EFI to activate the slot in EFI mode The options are Disabled Legacy and EFI Onboard LAN Option ROM Type Select an option to enable Option ROM suppor...

Страница 102: ...sabled and Enabled Ipv6 HTTP Support Select Enabled to enable Ipv6 HTTP boot support The options are Disabled and Enabled PXE boot wait time Use this option to specify the wait time to press the ESC k...

Страница 103: ...ice Settings This feature displays the status of a serial part specified by the user Change Settings This feature specifies the base I O port address and the Interrupt Request address of a serial port...

Страница 104: ...ta Bits Use this feature to set the data transmission size for Console Redirection The options are 7 and 8 Parity A parity bit can be sent along with regular data bits to detect data transmission erro...

Страница 105: ...ich is a terminal emulator designed for the Windows OS The options are VT100 LINUX XTERMR6 SC0 ESCN and VT400 Redirection After BIOS POST Use this feature to enable or disable legacy console redirecti...

Страница 106: ...bits to detect data transmission errors Select Even if the parity bit is set to 0 and the number of 1 s in data bits is even Select Odd if the parity bit is set to 0 and the number of 1 s in data bits...

Страница 107: ...legacy console redirection is disabled before booting the OS When this feature is set to Always Enable legacy console redirection remains enabled when booting the OS The options are Always Enable and...

Страница 108: ...nsmission speed may be required for long and busy lines The options are 9600 19200 57600 and 115200 bits per second Flow Control Use this feature to set the flow control for Console Redirection to pre...

Страница 109: ...twork security Please reboot the system for a change on this setting to take effect The options are Disable and Enable If the feature above is set to Enable the following features will become availabl...

Страница 110: ...d on the system Use this feature to enable or disable TXT Support The options are Disabled and Enabled HTTP Boot Configuration Use this feature to configure HTTP Boot settings for your system HTTP Boo...

Страница 111: ...s and Exit Select this feature to discard the changes you have made and exit from the system Delete Certification If this feature is set to Enable the certificate enrolled in the system will be delete...

Страница 112: ...DIMMs This feature configures and displays the information of a selected DCPMM Select a specific DIMM to view more information DIMMs on socket 0x0000 DIMM ID 0x0001 Press Enter and the following infor...

Страница 113: ...art number NMA1XBD256GQS Socket 0x0 Memory controller ID 0x0 Vendor ID 0x8089 Device ID 0x5141 Subsystem vendor ID 0x8089 Subsystem device ID 0x97A Device locator P1 DIMMA2 Subsystem revision ID 0x18...

Страница 114: ...kage spares available 1 Configuration status Valid SKU violation 0 ARS status Completed Overwrite DIMM status Not started Last shutdown time Fri Dec 21 17 29 23 UTC 2018 First fast refresh 0 Viral pol...

Страница 115: ...lear counter 0 Media temperature injection counter 0 Software triggers counter 0 Master Passphrase Enabled 0 DIMM ID 0x0101 Press Enter and the following information regarding this DIMM will be displa...

Страница 116: ...B35 Part number NMA1XBD256GQS Socket 0x0 Memory controller ID 0x1 Vendor ID 0x8089 Device ID 0x5141 Subsystem vendor ID 0x8089 Subsystem device ID 0x97A Device locator P1 DIMMD2 Subsystem revision ID...

Страница 117: ...ng enabled 1 Package spares available 1 Configuration status Valid SKU violation 0 ARS status Completed Overwrite DIMM status Not started Last shutdown time Fri Dec 21 17 29 23 UTC 2018 First fast ref...

Страница 118: ...ror clear counter 0 Media temperature injection counter 0 Software triggers counter 0 Master Passphrase Enabled 0 DIMM ID 0x0011 Press Enter and the following information regarding this DIMM will be d...

Страница 119: ...art number NMA1XBD256GQS Socket 0x0 Memory controller ID 0x0 Vendor ID 0x8089 Device ID 0x5141 Subsystem vendor ID 0x8089 Subsystem device ID 0x97A Device locator P1 DIMMB2 Subsystem revision ID 0x18...

Страница 120: ...sparing enabled 1 Package spares available 1 Configuration status Valid SKU violation 0 ARS status Completed Overwrite DIMM status Not started Last shutdown time Fri Dec 21 17 29 23 UTC 2018 First fas...

Страница 121: ...lear counter 0 Media temperature injection counter 0 Software triggers counter 0 Master Passphrase Enabled 0 DIMM ID 0x0111 Press Enter and the following information regarding this DIMM will be displa...

Страница 122: ...1C Part number NMA1XBD256GQS Socket 0x0 Memory controller ID 0x1 Vendor ID 0x8089 Device ID 0x5141 Subsystem vendor ID 0x8089 Subsystem device ID 0x97A Device locator P1 DIMME2 Subsystem revision ID 0...

Страница 123: ...able 1 Package sparing enabled 1 Package spares available 1 Configuration status Valid SKU violation 0 ARS status Completed Overwrite DIMM status Not started Last shutdown time Fri Dec 21 17 29 23 UTC...

Страница 124: ...ror injection counter 0 Poison error clear counter 0 Media temperature injection counter 0 Software triggers counter 0 Master Passphrase Enabled 0 DIMM ID 0x0021 Press Enter and the following informat...

Страница 125: ...0x00000B2E Part number NMA1XBD256GQS Socket 0x0 Memory controller ID 0x0 Vendor ID 0x8089 Device ID 0x5141 Subsystem vendor ID 0x8089 Subsystem device ID 0x97A Device locator P1 DIMMC2 Subsystem revi...

Страница 126: ...sparing enabled 1 Package spares available 1 Configuration status Valid SKU violation 0 ARS status Completed Overwrite DIMM status Not started Last shutdown time Fri Dec 21 17 29 23 UTC 2018 First fas...

Страница 127: ...lear counter 0 Media temperature injection counter 0 Software triggers counter 0 Master Passphrase Enabled 0 DIMM ID 0x0121 Press Enter and the following information regarding this DIMM will be displa...

Страница 128: ...AE Part number NMA1XBD256GQS Socket 0x0 Memory controller ID 0x0 Vendor ID 0x8089 Device ID 0x5141 Subsystem vendor ID 0x8089 Subsystem device ID 0x97A Device locator P1 DIMMF2 Subsystem revision ID 0...

Страница 129: ...able 1 Package sparing enabled 1 Package spares available 1 Configuration status Valid SKU violation 0 ARS status Completed Overwrite DIMM status Not started Last shutdown time Fri Dec 21 17 29 23 UTC...

Страница 130: ...or injection counter 0 Poison error clear counter 0 Media temperature injection counter 0 Software triggers counter 0 Master Passphrase Enabled 0 DIMMs on socket 0x0001 DIMM ID 0x1001 Press Enter and...

Страница 131: ...owing will be displayed Serial number 0x0000111C Part number NMA1XBD256GQS Socket 0x1 Memory controller ID 0x0 Vendor ID 0x8089 Device ID 0x5141 Subsystem vendor ID 0x8089 Subsystem device ID 0x97A De...

Страница 132: ...pacity 0 B Inaccessible capacity 0 B Reserved capacity 465 2 MiB Peak power budget mW 20000 Avg power budget mW 15000 Max average power budget mW 10000 Package sparing capable 1 Package sparing enable...

Страница 133: ...rect Boot status Success AIT DRAM enabled 1 Error injection enabled 0 Media temperature injection enabled 0 Software triggers enabled 0 Software triggers enabled details None Poison error injection co...

Страница 134: ...and Enabled If the feature Show more details is set to Enabled the following will be displayed Serial number 0x00001038 Part number NMA1XBD256GQS Socket 0x1 Memory controller ID 0x1 Vendor ID 0x8089 D...

Страница 135: ...App Direct capacity 0 B Unconfigured capacity 0 B Inaccessible capacity 0 B Reserved capacity 465 2 MiB Peak power budget mW 20000 Avg power budget mW 15000 Max average power budget mW 10000 Package...

Страница 136: ...ption Erase Modes supported Memory Mode App Direct Boot status Success AIT DRAM enabled 1 Error injection enabled 0 Media temperature injection enabled 0 Software triggers enabled 0 Software triggers...

Страница 137: ...out this DIMM The options are Disabled and Enabled If the feature Show more details is set to Enabled the following will be displayed Serial number 0x00000AA5 Part number NMA1XBD256GQS Socket 0x1 Memo...

Страница 138: ...20 Is new 0 Memory capacity 252 0 GiB App Direct capacity 0 B Unconfigured capacity 0 B Inaccessible capacity 0 B Reserved capacity 465 2 MiB Peak power budget mW 20000 Avg power budget mW 15000 Max a...

Страница 139: ...y capabilities Encryption Erase Modes supported Memory Mode App Direct Boot status Success AIT DRAM enabled 1 Error injection enabled 0 Media temperature injection enabled 0 Software triggers enabled...

Страница 140: ...isplay or hide additional information about this DIMM The options are Disabled and Enabled If the feature Show more details is set to Enabled the following will be displayed Serial number 0x00000E3A P...

Страница 141: ...D 0x8089 Controller revision ID B0 0x0020 Is new 0 Memory capacity 252 0 GiB App Direct capacity 0 B Unconfigured capacity 0 B Inaccessible capacity 0 B Reserved capacity 465 2 MiB Peak power budget m...

Страница 142: ...tched last shutdown status Unknown Security capabilities Encryption Erase Modes supported Memory Mode App Direct Boot status Success AIT DRAM enabled 1 Error injection enabled 0 Media temperature inje...

Страница 143: ...re to display or hide additional information about this DIMM The options are Disabled and Enabled If the feature Show more details is set to Enabled the following will be displayed Serial number 0x000...

Страница 144: ...rer ID 0x8089 Controller revision ID B0 0x0020 Is new 0 Memory capacity 252 0 GiB App Direct capacity 0 B Unconfigured capacity 0 B Inaccessible capacity 0 B Reserved capacity 465 2 MiB Peak power bud...

Страница 145: ...last shutdown status Unknown Security capabilities Encryption Erase Modes supported Memory Mode App Direct Boot status Success AIT DRAM enabled 1 Error injection enabled 0 Media temperature injection...

Страница 146: ...feature to display or hide additional information about this DIMM The options are Disabled and Enabled If the feature Show more details is set to Enabled the following will be displayed Serial number...

Страница 147: ...D 0x8089 Controller revision ID B0 0x0020 Is new 0 Memory capacity 252 0 GiB App Direct capacity 0 B Unconfigured capacity 0 B Inaccessible capacity 0 B Reserved capacity 465 2 MiB Peak power budget m...

Страница 148: ...ecurity capabilities Encryption Erase Modes supported Memory Mode App Direct Boot status Success AIT DRAM enabled 1 Error injection enabled 0 Media temperature injection enabled 0 Software triggers en...

Страница 149: ...he next system restart and select Update Current firmware version 01 00 00 5127 Selected firmware version None File Press Enter and type in the file path relative to the root directory of the device c...

Страница 150: ...d or Enabled will be displayed Enable Disable first fast refresh Use this feature to enable disable the feature above First fast refresh state Back to main menu Back to main menu Regions Use this subm...

Страница 151: ...space Label version While creating goals use this feature to display and modify the namespace label version to initialize The options are 1 2 and 1 1 Create goal config Use this feature to create goal...

Страница 152: ...Use this feature to save current namespace Delete Use this feature to delete current namespace Back to Namespaces Back to main menu Create namespace Name Press Enter to type in a name of namespace Re...

Страница 153: ...This feature displays the capacity of namespace Create namespace Press Enter to create a namespace with the above configuration Back to Namespace Back to main menu Back to main menu return to the main...

Страница 154: ...cs procedure for this DIMM The options are Disabled and Enabled DIMM ID 0x0011 Select Enabled to enable the diagnostics procedure for this DIMM The options are Disabled and Enabled DIMM ID 0x0111 Sele...

Страница 155: ...and Enabled FW diagnostics Select Enabled to enable the firmware diagnostics test The options are Disabled and Enabled Security diagnostics Select Enabled to enable the security diagnostics test The...

Страница 156: ...and or modify the default units for displaying capacities Use auto x1024 or Auto_10 x1000 to automatically select the best format The options are Auto Auto_10 B MB MiB GB GiB TB and TiB App Direct set...

Страница 157: ...y DIMM 43 Controller Healthy Intel Persistent Memory DIMM 51 Controller Healthy Intel Persistent Memory DIMM 29 Controller Healthy Intel Persistent Memory DIMM 37 Controller Healthy Intel Persistent M...

Страница 158: ...value on the Thunderbolt PCIe subtree The options are 0 1 2 4 8 16 32 64 and 128 SMI Notify Support Select Enabled to enable the SMI notification support The options are Disabled and Enabled SwSMI Sup...

Страница 159: ...o configure the Thunderbolt reserved memory for each physical slot If a PCIe device consumes less than X MB of memory the BIOS will reserve X MB per physical slot Reserved PMem per phy slot Use this f...

Страница 160: ...led and Enabled Erasing Settings Erase Event Log If No is selected data stored in the event log will not be erased Select Yes Next Reset data in the event log will be erased upon next system reboot Se...

Страница 161: ...duplicate event must happen before the MECI counter is incremented This is a numeric value The default value is 1 METW The Multiple Event Time Window METW defines number of minutes must pass between...

Страница 162: ...e IPMI firmware installed in your system System Event Log Enabling Disabling Options SEL Components Select Enabled for all system event logging at bootup The options are Disabled and Enabled Erasing S...

Страница 163: ...he options are No and Yes If the feature above is set to Yes the following features will become available for user s configuration Configuration Address Source This feature allows the user to select t...

Страница 164: ...V6 Support This feature displays the IPMI LAN setting The default setting is Enabled If the feature above is set to Enabled the following features will become available for user s configuration Config...

Страница 165: ...User Password Press Enter to set the user password which is required to enter the BIOS setup utility The length of the password should be from 3 characters to 20 characters long Password Check Select...

Страница 166: ...faults Select Enabled to install the default Secure Boot keys set by the manufacturer The options are Disabled and Enabled Enroll all Factory Default Keys Select Yes to install all default secure keys...

Страница 167: ...den Signature Database DBX contains forbidden certificates and digital signa tures Select Update to load the DBX from the manufacturer s defaults Select Append to add the DBX from the manufacturer s d...

Страница 168: ...s feature to enable the EFI boot support The options are Disabled and Enabled FIXED BOOT ORDER Priorities This feature prioritizes the order of bootable devices that the system to boot from Press Ente...

Страница 169: ...feature to remove a pre defined boot device from which the system will boot during startup The options are Select one to Delete and UEFI Built in EFI Shell UEFI Application Boot Priorities This featu...

Страница 170: ...Reset After completing the system configuration changes select this option to save the changes you have made This will reset reboot the system Save Changes When you have completed the system configur...

Страница 171: ...Save as User Defaults from the Exit menu and press Enter This enables the user to save any changes to the BIOS setup for future use Restore User Defaults To set this feature select Restore User Defaul...

Страница 172: ...continue the bootup procedure If a fatal error occurs you should consult with your system manufacturer for possible repairs The fatal errors are usually communicated through repeated patterns of audib...

Страница 173: ...m support manuals AMI BIOS POST Codes User s Guide When BIOS performs the Power On Self Test it writes checkpoint codes to I O port 0080h If the computer cannot complete the boot process a diagnostic...

Страница 174: ...n our website at www supermicro com support manuals Installing the OS 1 Create a method to access the MS Windows installation ISO file That might be a DVD perhaps using an external USB SATA DVD drive...

Страница 175: ...he USB flash drive for the proper driver files For RAID choose the SATA sSATA RAID driver indicated then choose the storage drive on which you want to install it For non RAID choose the SATA sSATA AHC...

Страница 176: ...act the ISO file if preferred Another option is to go to the Supermicro website at http www supermicro com products Find the product page for your motherboard and Download the Latest Drivers and Utili...

Страница 177: ...tion fan speed and provides alerts via email or Simple Network Management Protocol SNMP SuperDoctor 5 comes in local and remote management versions and can be used with Nagios to maximize your system...

Страница 178: ...o com products nfo IPMI cfm B 5 Logging into the BMC Baseboard Management Controller Supermicro ships standard products with a unique password for the BMC user This password can be found on a label on...

Страница 179: ...alling or configuring components These warnings may also be found on our website at http www supermicro com about policies safety_information cfm Battery Handling Warnung Bei Einsetzen einer falschen...

Страница 180: ...evaar indien de batterij verkeerd vervangen wordt Vervang de batterij slechts met hetzelfde of een equivalent type die door de fabrikant aanbevolen wordt Gebruikte batterijen dienen overeenkomstig fab...

Страница 181: ...tos nacionales Attention La mise au rebut ou le recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent...

Страница 182: ...ecovering the UEFI BIOS Image A UEFI BIOS flash chip consists of a recovery BIOS block and a main BIOS block a main BIOS image The recovery block contains critical BIOS codes including memory detectio...

Страница 183: ...UEFI BIOS recovery using a USB attached device follow the instructions below 1 Please use a different machine to download the BIOS package for your motherboard or your system from the product page ava...

Страница 184: ...ant to start the BIOS recovery If you decide to proceed with BIOS recovery follow the procedures below 6 When the screen as shown above displays use the arrow keys to select the item Proceed with flas...

Страница 185: ...menu list select Boot Option 1 as shown below Then set Boot Option 1 to UEFI AP UEFI Built in EFI Shell Press F4 to save the settings and exit the BIOS Setup utility 7 After the BIOS recovery process...

Страница 186: ...ry that contains the BIOS package you extracted earlier in Step 2 Enter flash nsh BIOSname at the prompt to start the BIOS update process Note Do not interrupt this process until the BIOS flashing is...

Страница 187: ...cro For the lat est updates please contact us or refer to our website at https www supermicro com Note 2 Depending on the version of driver utility package it may or may not have exactly the same as t...

Страница 188: ...at can be configured for VMD support on the screen 8 From the available PCI slots displayed on the screen select a PCI slot you want to use for a VMD device by highlighting it 9 Select the option Enab...

Страница 189: ...rollers has become available Note 1 The license and header on the motherboard for Intel VROC hardware key are required Also be sure the version of Intel Rapid Storage Technology enterprise Intel RSTe...

Страница 190: ...16 PCIe Intel VMD x16 PCIe Intel VMD x16 PCIe NVMe Device NVMe Device NVMe Device NVMe Device Processor Intel VMD x16 PCIe Intel VMD x16 PCIe Intel VMD x16 PCIe NVMe Device NVMe Device NVMe Device NVM...

Страница 191: ...ill appear Please carefully follow the instructions listed in this section to configure RAID settings for your devices as desired To Create a RAID Volume Use the arrow keys to select Create RAID Volum...

Страница 192: ...n above displays enter a unique name for the RAID volume To Enter a Name for the RAID Volume From the Create RAID Volume submenu as shown on the previous screen use the arrow keys to select Name and p...

Страница 193: ...es connected to the system Note 2 For RAID0 RAID1 RAID5 RAID10 the minimum number of NVMe devices required is two two three four respectively Note 3 Use Intel VROC Standard hardware key to support RAI...

Страница 194: ...ID spanned over VMD Controllers and press Enter The following screen will display Note For a bootable RAID volume do not cross VMD domains Enter a desired setting for your RAID volume in the pop up me...

Страница 195: ...ID Volumes From the Create RAID Volume submenu use the arrow keys to highlight Select Disk and press Enter The following screen will display The options are not selected and X selected Set the feature...

Страница 196: ...Strip Size and press Enter The following screen will display Note For RAID5 the options are 4KB 8KB 16KB 32KB 64KB and 128KB For RAID10 the options are 4KB 8KB 16KB 32KB and 64KB From the pop up menu...

Страница 197: ...Capacity GB for the RAID Volume From the Create RAID Volume submenu use the arrow keys to select Capacity GB and press Enter The following screen will display Enter the desired RAID capacity in GB in...

Страница 198: ...mes To finalize your RAID volume configuration select Create Volume from the Create RAID Volume submenu as shown on the screen below After selecting Create Volume press Enter The following screen will...

Страница 199: ...lume information use the arrow keys to select the desired RAID volume as shown below To Display RAID VOLUME Information When the screen above appears press Enter The RAID VOLUME INFO menu will appear...

Страница 200: ...RAID VOLUME INFO menu use the arrow keys to select Delete and press Enter to delete the RAID volume you have selected The following screen will appear to confirm if you want to delete the RAID Volume...

Страница 201: ...9 select the desired NVMe device from the list of RAID Member Disks and press Enter as shown below Select Reset to Non RAID from the screen below and press Enter to remove RAID data from the selected...

Страница 202: ...When the following screen displays select a non RAID physical disk to turn on the disk locator LED to locate a selected device You can also select a RAID member disk to locate the selected device When...

Страница 203: ...ection to access the All Intel VMD Controllers menu When the following screen appears select a desired NVMe device from the list of Non RAID Physical Disks After a NVMe device is selected press Enter...

Страница 204: ...want the selected device to be used as a spare device The options are Yes and No Note A spare disk is used for automatic RAID volume rebuilds when status of failed missing or at risk is detected on th...

Страница 205: ...n the E 1 section to access the All Intel VMD Controllers menu When the following screen appears select a desired NVMe device from the list of Non RAID Physical Disks for use as a journaling drive Aft...

Страница 206: ...5 volume The use of journaling drive that contains partial parity logging PPL can reduce the potential data loss Refer to the following illustration for the use of journaling drive Disk1 Journaling Dr...

Страница 207: ...a parity based RAID Press Enter and the following screen will appear Step 2 Use the arrow keys to select RWH Policy RWH is a scenario related to a power drive failure crash Step 1 Refer to the instruc...

Страница 208: ...the result of XOR calculation of old data and old parity PPL is a feature available for RAID5 volumes While a power drive failure crash occurring PPL information helps rebuild the RAID volume and re d...

Страница 209: ...feature RWH Policy to Journaling Drive Press Enter and the RWH JD feature will become available as shown below RWH JD Use the arrow keys to select RWH JD Press Enter and the following screen will appe...

Страница 210: ...ct use the arrow keys to select Change RWH settings and press Enter Your computer will return to the main screen of All Intel VMD Controllers as shown below Step 4 Use the arrow keys and press Enter t...

Страница 211: ...instructions on how to enable the secure boot features The F 4 section states Key Management settings F 1 Boot mode select Feature Press Del during system boot to enter the BIOS Setup utility Navigate...

Страница 212: ...dard and Custom Select Standard to load manufacturer s default secure variables Select Custom to change the image execution policy and to manage secure boot keys CSM Support Select Enabled to support...

Страница 213: ...have the secure boot support be sure to follow the steps below Step 1 Step 4 Step 1 Set Secure Boot Mode to Standard Press Yes to install factory default keys as needed Note The Key Management menu w...

Страница 214: ...e settings and exit the BIOS Setup utility Step 3 Press Del during system boot to enter the BIOS Setup utility Navigate to the Security tab and enter the Secure Boot menu Set CSM Support to Disabled F...

Страница 215: ...rver are allowed Step 4 Press Del during system boot to enter the BIOS Setup utility Navigate to the Security tab and enter the Secure Boot menu Set Secure Boot to Enabled For the changes to take effe...

Страница 216: ...Secure Boot Mode is set to Custom allows the secure boot keys to be installed via the external device and be involved in the secure boot process Provision Factory Defaults This feature is to provisio...

Страница 217: ...ult secure boot keys and key variables Also it will reset the system to the User mode The options are Yes and No Reset To Setup Mode available when the System Mode is in User mode Select and press Yes...

Страница 218: ...feature to export NVRAM content of secure boot variables to files in a root folder on a file system device Enroll Efi Image This feature is to enroll SHA256 hash of the binary into the Authorized Sign...

Страница 219: ...ble when the system is not in Device Guard Ready Select and press Yes to remove Microsoft UEFI CA certificate from the DB The options are Yes and No Restore DB defaults Select and press Yes to restore...

Страница 220: ...port Update and Delete Select Details to display detailed information of PK Select Export to save the current PKs to a FAT formatted USB flash drive Select Update to load the factory defaults or load...

Страница 221: ...1 Export Use the arrow keys to select Export It is to save the current PKs to a FAT for matted USB flash drive Note Refer to the right panel of the screen for the file formats accepted Press Enter and...

Страница 222: ...r X11DPG QT User s Manual 222 Press Enter and the following screen will appear Update Use the arrow keys to select Update It is to load the factory defaults or load PKs from a file on the external dev...

Страница 223: ...ndix F Secure Boot Settings 223 To load the factory defaults navigate to Yes and press Enter The following screen will appear To load PKs from a file on the external device navigate to No and press En...

Страница 224: ...Super X11DPG QT User s Manual 224 When the following screen appears select the USB flash drive that contains the desired file...

Страница 225: ...ndix F Secure Boot Settings 225 Delete Use the arrow keys to select Delete and press Enter to clear the current PKs and reset the system to the Setup mode Press Enter and the following screen will app...

Страница 226: ...led information of KEKs Select Export to save the current KEKs to a FAT formatted USB flash drive Select Update to load the factory defaults or load KEKs from a file on the external device Select Appe...

Страница 227: ...en will appear To load the factory defaults navigate to Yes and press Enter The following screen will appear To load KEKs from a file on the external device navigate to No and press Enter Refer to pag...

Страница 228: ...ser s Manual 228 Delete Use the arrow keys to select Delete and press Enter Navigate to Yes and press Enter to clear the current KEKs Navigate to No and press Enter to delete only one certificate from...

Страница 229: ...Export to save the cur rent DB to a FAT formatted USB flash drive Select Update to load the factory defaults or load DB from a file on the external device Select Append to add variables to the exist i...

Страница 230: ...elect Export to save the current DBX to a FAT formatted USB flash drive Select Update to load the factory defaults or load DBX from a file on the external device Select Append to add variables to the...

Страница 231: ...rt to save the cur rent DBT to a FAT formatted USB flash drive Select Update to load the factory defaults or load DBT from a file on the external device Select Append to add variables to the existing...

Страница 232: ...to save the current DBR to a FAT formatted USB flash drive Select Update to load the factory defaults or load DBR from a file on the external device Select Append to add variables to the exist ing DBR...

Страница 233: ...oup of storage devices or an intermediate device attached to storage devices The iSCSI initiator and iSCSI target must connect to an IP network To have iSCSI settings available refer to instructions s...

Страница 234: ...tionally these features will become unavailable except Onboard LAN1 Option ROM Onboard LAN1 Option ROM Use the arrow keys to select Onboard LAN1 Option ROM and press Enter The options are Disabled Leg...

Страница 235: ...select iSCSI Configuration and press Enter to access the menu items Ipv4 PXE Support Ipv6 PXE Support To enable Ipv4 Ipv6 PXE boot support use the arrow keys to select and set Ipv4 PXE Support Ipv6 PX...

Страница 236: ...User s Manual 236 G 2 Configuring iSCSI Settings iSCSI Initiator Name Use this feature to enter the unique initiator name in iSCSI qualified name IQN format Add an Attempt Use the arrow keys to select...

Страница 237: ...e This feature displays the iSCSI attempt name Press Enter and the following screen will appear Press Enter and the following screen will appear Use the arrow keys to select the desired media access c...

Страница 238: ...IO is a feature that allows the system to route I O through the available paths if the active path fails be sure to have more than one physical path connected to the system Internet Protocol Use this...

Страница 239: ...o enter the number of logon sessions allowed for the iSCSI initiator to restart with the iSCSI target if the first logon connection fails Connection Establishing Timeout Use this feature to set the lo...

Страница 240: ...t value is derived from the last three bytes of the OUI format ISID Also only the last three bytes of the ISID are configurable OUI format ISID This feature displays the default ISID in OUI format The...

Страница 241: ...ter the desired iSCSI initiator IP address Enable DHCP Use this feature to disable enable dynamic host configuration protocol DHCP server service for the iSCSI initiator The options are Disabled and E...

Страница 242: ...r Subnet Mask available when Enable DHCP is set to Disabled Use this feature to enter the desired iSCSI initiator subnet mask Gateway available when Enable DHCP is set to Disabled Use this feature to...

Страница 243: ...DHCP server service for the iSCSI target The options are Disabled and Enabled Note 1 Set the feature Get target info via DHCP to Disabled if you would like to specify the iSCSI target name IP address...

Страница 244: ...QT User s Manual 244 Target Address Use this feature to enter the desired iSCSI target IP address Target Port This feature displays the iSCSI target port Boot LUN Use this feature to enter the LUN ID...

Страница 245: ...o set the CHAP type The options are One way and Mutual Note Challenge handshake authentication protocol CHAP is a protocol used to verify the identity of the peer of a connection Note 1 If one way uni...

Страница 246: ...thentication Type is set to CHAP Use this feature to enter the CHAP name authenticated by the iSCSI target CHAP Secret available when Authentication Type is set to CHAP Use this feature to enter the C...

Страница 247: ...figuring iSCSI Settings 247 CHAP Status This feature displays the CHAP status Reverse CHAP Name available when CHAP Type is set to Mutual Use this feature to enter the CHAP name authenticated by the i...

Страница 248: ...ret available when CHAP Type is set to Mutual Use this feature to enter the CHAP secret 12 16 characters authenticated by the iSCSI initiator Reverse CHAP Status available when CHAP Type is set to Mut...

Страница 249: ...se the arrow keys to select Save Changes and press Enter to save settings shown on the screen Note For the changes to take effect save settings and restart the system Back to Previous Page Use the arr...

Страница 250: ...QT User s Manual 250 The user will be returned to the main screen of iSCSI Configuration as shown below Delete Attempts Use the arrow keys to select Delete Attempts Press Enter and the following scree...

Страница 251: ...onfiguring iSCSI Settings 251 Attempt 1 Use the feature to disable enable Attempt 1 The options are Disabled and Enabled Attempt 2 Use the feature to disable enable Attempt 2 The options are Disabled...

Страница 252: ...Manual 252 Commit Changes and Exit Press Enter to save changes and return to the main screen of iSCSI Configuration Discard Changes and Exit Press Enter to return to the main screen of iSCSI Configura...

Страница 253: ...Appendix G Configuring iSCSI Settings 253 Change Attempt Order Use the arrow keys to select Change Attempt Order Press Enter and the following screen will appear...

Страница 254: ...ys to move up down the selected Attempt For instance move up the selected Attempt by using key Move down the selected Attempt by using key Commit Changes and Exit Press Enter to save changes and retur...

Страница 255: ...s of onboard Intel LAN devices via the BIOS Setup utility supported by the Unified Extensible Firmware Interface UEFI driver H 1 Network Interface Card NIC Settings Press Del during system boot to ent...

Страница 256: ...become available for configuration as shown below Note If Onboard LAN1 Option ROM is set to EFI all features for onboard LAN op tion ROM will be set to EFI by the EFI driver Additionally these featur...

Страница 257: ...Interface Card NIC Settings 257 Use the arrow keys to select the desired onboard LAN device as shown below Press Enter and the following screen will appear It displays the detailed information for th...

Страница 258: ...X11DPG QT User s Manual 258 Blink LEDs This feature allows the user to set the LED blink duration in seconds The valid range is 0 15 seconds NIC Configuration Use the arrow keys to select NIC Configur...

Страница 259: ...9 Press Enter and the following screen will appear Wake on LAN Use the arrow keys to select Wake On LAN and press Enter The following screen will appear The options are Disabled and Enabled Set this f...