![Supermicro X10DRX Скачать руководство пользователя страница 43](http://html1.mh-extra.com/html/supermicro/x10drx/x10drx_user-manual_1404010043.webp)
2-20
X10DRX Motherboard User’s Manual
FANB
COM1
IPMI LAN
USB 4/5 (3.0)
USB 0/1 (2.0)
LAN1
LAN2
VGA
UID-SW
UID-LED
FANC
BMC FWR
COM2
X10DRX
Rev. 100
JIPMB1
JPL1
JPB1
JPG1
JPME2
JWD1
CPU1 Slot1 PCI-E 3.0x8
CPU1 Slot2 PCI-E 3.0x8
CPU1 Slot3 PCI-E 3.0x8
CPU1 Slot4 PCI-E 3.0x8
CPU1 Slot5 PCI-E 3.0x8
CPU2 Slot6 PCI-E 3.0x8
CPU2 Slot7 PCI-E 3.0x8
CPU2 Slot8 PCI-E 3.0x8
CPU2 Slot9 PCI-E 3.0x8
CPU2 Slot10 PCI-E 3.0x8
CPU2 Slot1
1 PCI-E 2.0x4 in x8
JP
I2C1
P1-DIMMA1
P1-DIMMA2
P1-DIMMB1
P1-DIMMB2
Always populate DIMM1 first
USB 6 (3.0)
TPM/Port80
Front CTRL Panel
JF1
USB 2/3 (2.0)
USB 7/8 (3.0)
S-SATA0
S-SATA1
S-SATA2
S-SA
TA3
I-SA
TA0
I-SA
TA2
I-SA
TA1
I-SA
TA3
I-SA
TA5
I-SGPIO1
I-SGPIO2
S-SGPIO1
JL1
I-SA
TA4
FANA
JSD2
JSD1
FAN-I1
JBT1
JBAT1
Battery
BIOS
SP1
FAN3
JVR1
FAN2
FAN6
CPU1
FAN1
JPWR1
JPWR2
JPWR3
FAN7
CPU2
P1-DIMMD2
P1-DIMMD1
P1-DIMMC2
P1-DIMMC1
P2-DIMMF2
P2-DIMMF1
P2-DIMME2
P2-DIMME1
P2-DIMMG1
P2-DIMMG2
P2-DIMMH1
P2-DIMMH2
JSTBY1
JI2C1
JI2C2
J23
FAND
FAN4
FAN5
JPWR4
JNVI2C1
JNVI2C2
BMC CTRL
LAN CTRL
PCH
JTPM1
JUIDB1
LEM1
LED2
LED1
CPU2
CPU1
Power Button
OH/Fan Fail/
PWR Fail LED)
1
NIC1 Link LED
Reset Button
2
Power Fail LED
HDD LED
FP PWRLED
Reset
PWR
3.3 V
UID Switch
UID LED
Ground
Ground
19
20
3.3V
X
Ground
NMI
X
NIC2 Link LED
NIC2 Activity LED
NIC1 Activity LED
1. UID Switch (on the I/O
Back Panel)
2. Rear UID LED (on the
motherboard)
3. Front UID LED (on the
Front CTRL Panel)
4. Front UID Switch (on
the Front CTRL Panel)
3
Unit Identifier Switches & UID LED
Indicators
A rear unit identifier switch (JUIDB1) is located
next to the VGA port on the IO back panel, and
a front UID switch is located on pin 13 on the
front control panel (JF1). The rear UID LED
(LED1) is located next to the rear UID switch,
and the front UID LED is located on pins 7 on
JF1. When you press the front UID switch or
the rear UID switch, both front and rear UID
LED indicators will be turned on. Press the
UID switch again to turn off the LEDs. The
UID Indicators provide easy identification of
a system unit that may be in need of service.
Refer to the layout below for the locations of
the front control panel and the I/O back panel.
Note:
UID can also be triggered via
IPMI on the motherboard. For more
information on IPMI, please refer to
the IPMI User's Guide posted on our
website @http://www.supermicro.
com.
UID Button
Pin# Definition
1
Ground
2
Ground
3
Button In
4
Button In
UID LED
Status
Color/State Status
Blue: On
Unit Identified
4
2
Front Control Panel (JF1)
I/O Back Panel
1
1
JF1
Содержание X10DRX
Страница 1: ...USER S MANUAL Revision 1 0 X10DRX...
Страница 114: ...A 2 X10DRU i Motherboard User s Manual Notes...