background image

112

111

SuperWorkstation 5039D-I User's Manual

Appendix B: Standardized Warning Statements

Warnung
Die Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen 
wird. Halten Sie Finger, Schraubendreher und andere Gegenstände von den Öffnungen des 
Lüftergehäuses entfernt.

¡Advertencia! 

Los ventiladores podran dar vuelta cuando usted quite ell montaje del ventilador del chasis. 
Mandtenga  los  dedos,  los  destornilladores  y  todos  los  objetos  lejos  de  las  aberturas  del 

ventilador

Attention 

Il est possible que les ventilateurs soient toujours en rotation lorsque vous retirerez le bloc 
ventilateur du châssis. Prenez garde à ce que doigts, tournevis et autres objets soient éloignés 

du logement du bloc ventilateur.

!הרהזא

 

יקלח תא םיריסמ רשאכ

 

 שי .םידבוע ןיידע םיררוואמהו ןכתי ,זראמהמ ררוואמה

 קיחרהל

ל

ררוואמה ךותב םיחתפהמ םינוש הדובע ילכו תועבצאה תא חוטב קחרמ

 

 

هكممنا هم

 

حوارمنا نأ

 

لاست لا

 

ةنازإ دنعرودت

 

ةهتك

 

ةحورمنا

 

مكيهنا هم

 

بجي

 

ءاقبإ

 

عباصلأا

 

و

يغاربنا تاكفم

 

.

ءايشلأا هم اهريغو

 

اديعب

 

هع

 

تاحتفنا

 

يف

 

ةهتك

 

ةحورمنا

  

 

 

경고!

섀시로부터 팬 조립품을 제거할 때 팬은 여전히 회전하고 있을 수 있습니다. 팬 조림품 
외관의 열려있는 부분들로부터 손가락 및 스크류드라이버, 다른 물체들이 가까이 하지 
않도록 배치해 주십시오. 

Waarschuwing

Het is mogelijk dat de ventilator nog draait tijdens het verwijderen van het ventilatorsamenstel 

uit het chassis. Houd uw vingers, schroevendraaiers en eventuele andere voorwerpen uit de 
buurt van de openingen in de ventilatorbehuizing.

Power Cable and AC Adapter 

Warnung 
Bei der Installation des Produkts, die zur Verfügung gestellten oder benannt Anschlusskabel, 
Stromkabel und Netzteile. Verwendung anderer Kabel und Adapter kann zu einer Fehlfunktion 
oder ein Brand entstehen. Elektrische Geräte und Material Safety Law verbietet die 

Verwendung von UL-oder CSA-zertifizierte Kabel, UL oder CSA auf der Code für alle anderen 

elektrischen Geräte als Produkte von Supermicro nur bezeichnet gezeigt haben.

¡Advertencia! 
Al instalar el producto, utilice los cables de conexión previstos o designados, los cables y 
adaptadores de CA. La utilización de otros cables y adaptadores podría ocasionar un mal 
funcionamiento o un incendio. Aparatos Eléctricos y la Ley de Seguridad del Material prohíbe 

el uso de UL o CSA cables certificados que tienen UL o CSA se muestra en el código de 

otros dispositivos eléctricos que los productos designados por Supermicro solamente.

電源コードとACアダプター
製品を設置する場合、提供または指定された接続ケーブル、電源コードとACアダプターを使用下さ
い。 他のケーブルやアダプタを使用すると故障や火災の原因になることがあります。 電気用品安全
法は、ULまたはCSA認定のケーブル(UL/CSEマークがコードに表記)を  Supermicroが指定する製
品以外に使用することを禁止しています。

警告
安装此产品时,请使用本身提供的或指定的连接线,电源线和电源适配器.使用其它线材或适配
器可能会引起故障或火灾。除了Supermicro所指定的产品,电气用品和材料安全法律规定禁止
使用未经UL或CSA认证的线材。(线材上会显示UL/CSA符号)。

警告
安裝此產品時,請使用本身提供的或指定的連接線,電源線和電源適配器.使用其它線材或適配
器可能會引起故障或火災。除了Supermicro所指定的產品,電氣用品和材料安全法律規定禁止
使用未經UL或CSA認證的線材。(線材上會顯示UL/CSA符號)。

Warning! 

When installing the product, use the provided or designated connection 

cables, power cables and AC adaptors. Using any other cables and adaptors could 

cause a malfunction or a fire. Electrical Appliance and Material Safety Law prohibits 
the use of UL or  CSA -certified cables (that have  UL/CSA shown on the code) for any 

other electrical devices than products designated by Supermicro only.

Содержание SuperWorkstation 5039D-I

Страница 1: ...rence when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer...

Страница 2: ...hout notice Please check the Supermicro website for possible updates to the manual revision level Warnings Special attention should be given to the following symbols used in this manual Warning Indica...

Страница 3: ...Dist New Taipei City 235 Taiwan R O C Tel 886 2 8226 3990 Fax 886 2 8226 3992 Email support supermicro com tw Website www supermicro com tw Chapter 4 Motherboard Connections 4 1 Power Connections 33 4...

Страница 4: ...x the SuperWorkstation 5039D I was shipped in and note if it was damaged in any way If any equipment appears damaged please file a damage claim with the carrier who delivered it The system should be s...

Страница 5: ...may be caused by cable congestion Blinking red 1Hz Fan failure check for an inoperative fan Solid blue Local UID has been activated Use this function to locate the server in a rackmount environment Bl...

Страница 6: ...e illustration below shows the features included on the rear of the chassis 1 3 2 Front Chassis Features Item Feature Description 1 Fixed Drive Area Supports two fixed 5 25 drives such as a DVD ROM or...

Страница 7: ...entifier Switch LAN1 LAN2 Gigabit RJ45 Ports PCI E CPU Slot 7 PCI Express 3 0 x8 Slot PCI E CPU Slot 6 PCI Express 3 0 x8 in x16 Slot Table continued on next page Figure 1 4 Motherboard Layout 1 5 Mot...

Страница 8: ...3 0 USB 2 0 USB3 0 USB2 0 TPM Header Debug Card BIOS MUX LPC SPI SPI SPI FRONT PANEL FAN SPEED CTRL SYSTEM POWER VGA CONN COM1 Connector COM2 Header BMC AST2400 BMC Boot Flash DDR3 RJ45 Temp Sensor EM...

Страница 9: ...ted circuit boards it is important to use a grounded wrist strap handle all PCBs by their edges and keep them in anti static bags when not in use 2 2 Preparing for Setup Precautions Review the electri...

Страница 10: ...dant power supply 1 Use the operating system to power down the system 2 After the system has completely shut down disconnect the AC power cord from the power strip or outlet 3 Disconnect the power cor...

Страница 11: ...to install a processor CPU and heatsink to the motherboard Notes The motherboard should be installed into the chassis first and the processor should be installed into the CPU socket before you instal...

Страница 12: ...ative purposes only A different heatsink may be used in the 5039D I 5 With the processor inserted into the socket inspect the four corners of the CPU to make sure that it is properly installed and flu...

Страница 13: ...he module snaps into place 4 Press the release tabs to the locked positions to secure the DIMM module into the slot Repeat for other DIMM slots as needed See next page for population sequence 5 To rem...

Страница 14: ...tery may release hazardous materials into the environment Do not discard a used battery in the garbage or a public landfill Please comply with the regulations set up by your local hazardous waste mana...

Страница 15: ...talled or removed Installing a Hard Drive Begin by removing power from the system as described in section 3 1 and remove the chassis cover as described in section 3 2 1 To rotate the hard drive cage l...

Страница 16: ...rill aligning the mounting holes of the fan grill with the mounting holes of the system fan 4 Pull the rubber pins through the mounting holes of the system fan to secure the fan to the chassis 4 Optio...

Страница 17: ...ion 3 1 and access the inside of the system as described in section 3 2 1 Remove the screws securing the power supply to the chassis These are located on the rear of the chassis Set these screws aside...

Страница 18: ...ction ATX Power 24 pin Connector Pin Definitions Pin Definition Pin Definition 13 3 3V 1 3 3V 14 12V 2 3 3V 15 Ground 3 Ground 16 PS_ON 4 5V 17 Ground 5 Ground 18 Ground 6 5V 19 Ground 7 Ground 20 Res...

Страница 19: ...o power connectors for SATA DOM Disk_On_Module devices are located at JSD1 JSD2 Connect appropriate cables here to provide power support for your Serial Link DOM devices DOM Power Pin Definitions Pin...

Страница 20: ...of a chassis intrusion when the chassis is opened Chassis Intrusion Pin Definitions Pin Definition 1 Intrusion Input 2 Ground Unit Identifier Switch UID LED Indicator A rear Unit Identifier UID switch...

Страница 21: ...rn off the power when the system is in suspend mode press the button for 4 seconds or longer Power Button OH Fan Fail LED 1 NIC1 Link Active LED Reset Button 2 Power Fail LED HDD LED FP PWRLED Reset P...

Страница 22: ...rive activity status Attach a cable to Pin 13 to use UID switch Refer to the table below for pin definitions HDD LED Pin Definitions JF1 Pin Definition 13 3 3V Standby UID Switch 14 HDD Active Power L...

Страница 23: ...2 0 Pin Definitions Pin Definition Pin Definition 1 5V 5 5V 2 USB_N 6 USB_N 3 USB_P 7 USB_P 4 Ground 8 Ground Universal Serial Bus USB Ports There are two USB 2 0 ports USB 0 1 and two USB 3 0 ports...

Страница 24: ...t is located above the USB 0 1 ports All of these ports accept RJ45 cables Please refer to the LED Indicator section for LAN LED information CMOS Clear JBT1 is used to clear CMOS which will also clear...

Страница 25: ...r JPME2 to bypass SPI flash security and force the system to operate in the manufacturer mode which will allow the user to flash the system firmware from a host server for system setting modifications...

Страница 26: ...ated on the rear I O panel The LED on the right indicates activity while the LED on the left indicates the speed of the connection IPMI LAN LEDs LED Color State Definition Link left Green Solid Amber...

Страница 27: ...he Windows OS Setup screen will display 3 From the Windows OS Setup screen press the Enter key The OS Setup will automatically load all device files and then continue with the Windows installation 4 A...

Страница 28: ...With SuperDoctor 5 Management Server SSM Server you can remotely control power on off and reset chassis intrusion for multiple systems with SuperDoctor 5 or IPMI SuperDoctor 5 Management Server monit...

Страница 29: ...es built in We retain the option to include omit or change any of these text messages Settings printed in Bold are the default values A indicates a submenu Highlighting such an item and pressing the E...

Страница 30: ...revert to the default to the manufacture default settings Boot Feature Quiet Boot Use this feature to select the screen display between the POST messages and the OEM logo upon bootup Select Disabled...

Страница 31: ...for more than 5 minutes The options are Enabled and Disabled Power Button Function This feature controls how the system shuts down when the power button is pressed Select 4_Seconds_Override for the u...

Страница 32: ...y to reduce power consumption and heat dissipation The options are Disabled and Enabled Turbo Mode Select Enabled for processor cores to run faster than the frequency specified by the manufacturer The...

Страница 33: ...m to reduce power consumption The options are Enabled and Disabled Chipset Configuration Warning Setting the wrong values in the following features may cause the system to malfunc tion System Agent SA...

Страница 34: ...board to change this value The default setting is 75 SLOT6 Slot Power Limit Scale Use this feature to select the scale used for the slot power limit value The options are 1 0x 0 1x 0 01x and 0 001x CP...

Страница 35: ...PCH SKU Name Intel PCH Rev ID PCI Express Configuration DMI Link ASPM Control Use this feature to set the ASPM Active State Power Management state on the SA System Agent side of the DMI Link The optio...

Страница 36: ...ive on the particular SATA port Model number of drive and capacity Software Preserve Support Port 0 Port 7 Spin Up Device Port 6 and Port 7 on X11SSM F only On an edge detect from 0 to 1 set this item...

Страница 37: ...abled PXE boot wait time Use this option to specify the wait time to press the ESC key to abort the PXE boot Press or on your keyboard to change the value The default setting is 0 Media detect count U...

Страница 38: ...ey support Select ANSI to use the Extended ASCII Character Set Select VT UTF8 to use UTF8 encoding to map Unicode characters into one or more bytes The options are VT100 VT100 VT UTF8 and ANSI COM1 Bi...

Страница 39: ...set the transmission speed for a serial port used in Console Redirection Make sure that the same speed is used in the host computer and the client computer A lower transmission speed may be required f...

Страница 40: ...usy lines The options are 9600 19200 57600 and 115200 bits per second Flow Control Use this item to set the flow control for Console Redirection to prevent data loss caused by buffer overflow Send a S...

Страница 41: ...tect against software based attacks and ensures protection confidentiality and integrity of data stored or created on the system Use this feature to enable or disable TXT Support The options are Disab...

Страница 42: ...will allow the system to wake up when an onboard device receives an incoming signal The options are Disabled and Enabled Blink LEDs Use this feature to identify the physical network port by blinking t...

Страница 43: ...tely for all messages to be automatically erased from the event log when the event log memory is full The options are Do Nothing and Erase Immediately SMBIOS Event Long Standard Settings Log System Bo...

Страница 44: ...take effect BMC Network Configuration BMC Network Configuration IPMI LAN Selection This item displays the IPMI LAN setting The default setting is Failover IPMI Network Link Status This item displays t...

Страница 45: ...configure the following security settings for the system Password Check Select Setup for the system to check for a password at Setup Select Always for the system to check for a password at bootup or...

Страница 46: ...are Yes and No Key Exchange Key Set New Key Select Yes to load the KEK from the manufacturer s defaults Select No to load the KEK from a file The options are Yes and No Append Key Select Yes to add t...

Страница 47: ...r 6 Legacy UEFI Dual Boot Order 7 Legacy UEFI Dual Boot Order 8 Legacy UEFI Dual Boot Order 9 Legacy UEFI Dual Boot Order 10 Legacy UEFI Dual Boot Order 11 Legacy UEFI Dual Boot Order 12 Legacy UEFI D...

Страница 48: ...changes you have made This will not reset reboot the system Discard Changes Select this option and press Enter to discard all the changes and return to the AMI BIOS utility Program Default Options Res...

Страница 49: ...or Beep POST Codes Beep Code Error Message Description 1 beep Refresh Circuits have been reset Ready to power up 5 short 1 long Memory error No memory detected in system 5 beeps No con in or con out d...

Страница 50: ...mit den Gefahren elektrischer Schaltungen und den blichen Verfahren zur Vorbeugung vor Unf llen vertraut Suchen Sie mit der am Ende jeder Warnung angegebenen Anweisungsnummer nach der jeweiligen bers...

Страница 51: ...R DEZE INSTRUCTIES Installation Instructions Warning Read the installation instructions before connecting the system to the power source Warnung Vor dem Anschlie en des Systems an die Stromquelle die...

Страница 52: ...sche installatie Controleer of het beveiligde aparaat niet groter gedimensioneerd is dan 250V 20A Power Disconnection Warning Warnung Das System muss von allen Quellen der Energie und vom Netzanschlus...

Страница 53: ...n dieser Ausr stung sollte nur geschultem qualifiziertem Personal gestattet werden Advertencia Solamente el personal calificado debe instalar reemplazar o utilizar este equipo Restricted Area Waarschu...

Страница 54: ...n alleen verkregen worden door gebruik te maken van speciaal gereedschap slot en sleutel of andere veiligheidsmaatregelen Battery Handling Warnung Bei Einsetzen einer falschen Batterie besteht Explosi...

Страница 55: ...the unit Warnung Dieses Ger t kann mehr als eine Stromzufuhr haben Um sicherzustellen dass der Einheit kein trom zugef hrt wird m ssen alle Verbindungen entfernt werden Waarschuwing Deze eenheid kan m...

Страница 56: ...ntenance Warning Hazardous voltage or energy is present on the backplane when the system is operating Use caution when servicing Comply with Local and National Electrical Codes Warnung Die Installatio...

Страница 57: ...vertencia Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales Waarschuwing De uiteindelijke verwijdering van dit product dient te geschieden in overeenstem...

Страница 58: ...Anschlusskabel Stromkabel und Netzteile Verwendung anderer Kabel und Adapter kann zu einer Fehlfunktion oder ein Brand entstehen Elektrische Ger te und Material Safety Law verbietet die Verwendung vo...

Страница 59: ...es appareils lectriques que les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA UL CSA Supermicro UL CSA AC Electrical Appliance and Material Safety Law UL CSA UL CSA Waarschuwing Bij h...

Страница 60: ...2 x 1 7 x 20 in 437 x 43 x 508 mm W x H x D System Cooling Two 4 cm high performance fans Power Supply Model PWS 305 PQ AC Input Voltages 100 240 VAC Rated Input Current 5A maximum Rated Input Frequen...

Отзывы: