background image

USER’S MANUAL

Revision 1.0

S

UpER

S

toRAgE

 S

ERvER

®

2028R-NR48N

Содержание SuperStorage Server 2028R-NR48N

Страница 1: ...USER S MANUAL Revision 1 0 SuperStorage Server 2028R NR48N...

Страница 2: ...f any such disputes Super Micro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and found to comply with the limit...

Страница 3: ...s page on our Web site for updates on supported memory processors and operating systems www supermicro com This manual may be periodically updated without notice Please check the Supermicro Web site f...

Страница 4: ...on 2 1 Unpacking the System 2 1 2 2 Preparing for Setup 2 1 Choosing a Setup Location 2 1 2 3 Warnings and Precautions 2 2 Rack Precautions 2 2 General Server Precautions 2 2 Rack Mounting Considerati...

Страница 5: ...em 4 12 Backplane Voltage if applicable to your system 4 13 Comply with Local and National Electrical Codes 4 14 Product Disposal 4 15 Hot Swap Fan Warning if applicable to your system 4 16 Power Cabl...

Страница 6: ...3 Rear Cover 6 4 6 4 Storage Drives 6 5 Drive Connections 6 5 Drive Carriers 6 6 Installing a Solid State Drive SSD 6 7 Installing Rear Hard Drives 6 8 6 5 Installing the Expansion Cards 6 9 6 6 Inst...

Страница 7: ...vii Preface Appendix A BIOS Error Beep Codes Appendix B UEFI BIOS Recovery Instructions Appendix C System Specifications...

Страница 8: ...viii SuperStorage Server 2028R NR48N Notes...

Страница 9: ...or information on operating systems that have been certified for use with the system www supermicro com In addition to the above components the server includes Two SAS3 backplanes BPN SAS3 226SEL1 N4...

Страница 10: ...133 1866 1600 memory See Chapter 5 for details NVMe Ports The motherboard features four NVMExpress ports PCI E 3 0 x4 using OCuLink The NVMe ports provide high speed low latency connections directly f...

Страница 11: ...x4 4 7 0 3 port 1 2 with RJ45 REAR port 3 TYPE A x8 x16 PCIe Slot1 PCIe Slot2 PCIe Slot3 0 15 x8 x16 0 15 NCSI NVMe1 NVMe2 NVMe3 NVMe4 x4 12 15 x4 JMAZZ1 SAS AOM1 0 7 SPI PEI BMC AST2400 HWM VGA LAN L...

Страница 12: ...ted by a separate backplane the rear most referred to herein as the mid plane The chassis also supports two additional hot swap 2 5 hard drives at the rear PCI Expansion Slots The system allows three...

Страница 13: ...e Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro...

Страница 14: ...1 6 SuperStorage Server 2028R NR48N Notes...

Страница 15: ...here heat electrical noise and electromagnetic fields are generated A nearby grounded power outlet is required The box your chassis was shipped in should include two sets of rail assemblies two rail m...

Страница 16: ...sly may cause the rack to become unstable General Server Precautions Review the electrical and general safety precautions that came with the components you are adding to your chassis Determine the pla...

Страница 17: ...equipment nameplate ratings should be used when addressing this concern Reliable Ground A reliable ground must be maintained at all times To ensure this the rack itself should be grounded Particular a...

Страница 18: ...are using Note This rail will fit a rack between 26 5 and 36 4 deep Identifying the Sections of the Rack Rails The chassis package includes two rail assemblies in the rack mounting kit Each assembly c...

Страница 19: ...Releasing the Inner Rail from the Middle and Outer Rails 1 Lift the front latch on the inner rail and pull the inner rail out of the middle rail and the middle rail out of the outer rail until the rai...

Страница 20: ...the side of the chassis aligning the pins on the side of the chassis with the slotted thru holes in the inner rail 3 Slide the inner rail toward the rear of the chassis until the pins are at the end o...

Страница 21: ...that slide to lengthen Pull out the rear of the outer rail adjusting the length until the square pin assembly passes then fits against the back of the rear post Be careful to keep the rail level 5 Ins...

Страница 22: ...assis with the front of the middle rails 3 Slide the inner rails on the chassis into the middle rails keeping the pressure even on both sides When partially in the locking levers will stop further pro...

Страница 23: ...Removing the Chassis 1 Lift the right and left front latches which are just below the LED control panels on the front edges of the chassis 2 Pull the chassis forward until it clicks to a stop 3 Press...

Страница 24: ...pins and the front of the rail from the rack 3 Support the front of the outer and middle rail assembly while releasing the rear 4 Remove the outer rail from the rear of the rack in the same way as th...

Страница 25: ...ded out the front of the rack The kit includes six fabric Velcro cable ties The CMA attaches to the rack mounting rails by means of four connectors They are labled on the connectors 1 2 3 and 4 Instal...

Страница 26: ...4 align the metal tabs with the slots on the rear of the left outer rail and push it forward It snaps into place 5 Open the six red plastic caps and route the cables into the wire carrier 6 Use the s...

Страница 27: ...m the CMA releasing the Velcro straps and the red plastic caps 2 For CMA connector 4 pull the metal release tab toward the center of the rack and slide the connector toward the rear to release it 3 Fo...

Страница 28: ...SuperStorage Server 2028R NR48N 2 14 Notes...

Страница 29: ...The server includes a control panel on the front that house power buttons and status monitoring lights The externally accessible hard drives display status lights The power supply displays status ligh...

Страница 30: ...intains standby power To perform most maintenance tasks unplug the system to remove all power Reset The reset button is used to reboot the system 3 2 Control Panel Buttons The chassis control panel in...

Страница 31: ...d red An overheat condition has occured This may be caused by cable congestion Blinking red 1Hz Fan failure check for an inoperative fan Blinking red 0 25Hz Power failure check for a non operational p...

Страница 32: ...r displays two LED indicators an activity indicator and a status indicator The status indicator functions in RAID configurations For non RAID configurations it remains off See the table below for deta...

Страница 33: ...supply is on Solid Amber When illuminated indicates the power supply is plugged in and turned off or the system is off but in an abnormal state Blinking Amber When blinking this system power supply te...

Страница 34: ...SuperStorage Server 2028R NR48N 3 6 Notes...

Страница 35: ...y certified technicians should attempt to install or configure components Read this chapter in its entirety before installing or configuring components in the Supermicro chassis Some warnings may not...

Страница 36: ...sidere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontrar el t...

Страница 37: ...k letsel kan veroorzaken Voordat u aan enige apparatuur gaat werken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaa...

Страница 38: ...en des Systems an die Stromquelle die Installationsanweisungen lesen Advertencia Lea las instrucciones de instalaci n antes de conectar el sistema a la red de alimentaci n Attention Avant de brancher...

Страница 39: ...ert ist Stellen Sie sicher dass der Nennwert der Schutzvorrichtung nicht mehr als 250 V 20 A betr gt Advertencia Este equipo utiliza el sistema de protecci n contra cortocircuitos o sobrecorrientes de...

Страница 40: ...t um Systemsbestandteile anzubringen oder zu entfernen Warning The system must be disconnected from all sources of power and the power cord removed from the power supply module s before accessing the...

Страница 41: ...nentes de sistema Attention Le syst me doit tre d branch de toutes les sources de puissance ainsi que de son cordon d alimentation secteur avant d acc der l int rieur du chassis pour installer ou enle...

Страница 42: ...ng Das Installieren Ersetzen oder Bedienen dieser Ausr stung sollte nur geschultem qualifiziertem Personal gestattet werden Advertencia Solamente el personal calificado debe instalar reemplazar o util...

Страница 43: ...stallation in Bereichen mit beschr nktem Zutritt vorgesehen Der Zutritt zu derartigen Bereichen ist nur mit einem Spezialwerkzeug Schloss und Schl ssel oder einer sonstigen Sicherheitsvorkehrung m gli...

Страница 44: ...or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions Waarschuwing Dit apparaat is bedoeld voor installatie in gebieden met een bep...

Страница 45: ...ecommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incorrecta Reemplazar la bat...

Страница 46: ...limentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Attention Cette unit peut avoir plus d une connexion d alimentation Pour supprimer toute tension...

Страница 47: ...del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques circulent sur le fond de panier Prendre des pr cautions lors d...

Страница 48: ...trical codes Warnung Die Installation der Ger te muss den Sicherheitsstandards entsprechen Advertencia La instalacion del equipo debe cumplir con las normas de electricidad locales y nacionales Backpl...

Страница 49: ...ional laws and regulations Attention L quipement doit tre install conform ment aux normes lectriques nationales et locales Waarschuwing Bij installatie van de apparatuur moet worden voldaan aan de lok...

Страница 50: ...leyes y reglamentos nacionales Attention La mise au rebut ou le recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l org...

Страница 51: ...dedos los destornilladores y todos los objetos lejos de las aberturas del ventilador Attention Il est possible que les ventilateurs soient toujours en rotation lorsque vous retirerez le bloc ventilat...

Страница 52: ...ter kann zu einer Fehlfunktion oder ein Brand entstehen Elektrische Ger te und Material Safety Law verbietet die Verwendung von UL oder CSA zertifizierte Kabel UL oder CSA auf der Code f r alle andere...

Страница 53: ...utres appareils lectriques que les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA UL CSA Supermicro UL CSA AC Electrical Appliance and Material Safety Law UL CSA UL CSA Waarschuwing Bi...

Страница 54: ...4 20 SuperStorage Server 2028R NR48N Notes...

Страница 55: ...s chapter To prevent the motherboard from bending keep one hand under the center of the board to support it when handling The following measures are generally sufficient to protect your equipment from...

Страница 56: ...Power Connections Power is routed from the power supplies to the power distribution board which in turn connects to the midplane When the motherboards are seated in their bays they plug into the midpl...

Страница 57: ...U separately use only an Intel certified multi directional heatsink Avoid placing direct pressure to the top of the processor package Install the processor into the CPU socket before installing the he...

Страница 58: ...ges will fit the socket OPEN1st IMPORTANT Caution You can only install the CPU into the socket in one direction Make sure that the CPU is properly inserted into the socket before closing the load plat...

Страница 59: ...and lock the Close 1st lever Push down and lock the lever labeled Open 1st OPEN1st OPEN1st Push down and lock the lever labeled Close 1st 9 Close and lock the Open 1st lever Engage the lip of the load...

Страница 60: ...aution Removing the CPU or the heatsink is not recommended If you do need to remove the heatsink please follow the instructions below to prevent damage to the CPU or other components Installing a CPU...

Страница 61: ...updates please refer to the product page on our website DIMM Installation Caution Exercise extreme care when installing or removing DIMM modules to prevent any possible damage Installing Memory Module...

Страница 62: ...DIMMB1 P1 DIMMC1 P1 DIMMD1 any pair of P1 DIMMA2 P1 DIMMB2 P1 DIMMC2 P1 DIMMD2 slots 2 CPUs 4 DIMMs CPU1 CPU2 P1 DIMMA1 P1 DIMMB1 P2 DIMME1 P2 DIMMF1 2 CPUs 6 DIMMs CPU1 CPU2 P1 DIMMA1 P1 DIMMB1 P1 DI...

Страница 63: ...3 DPC E5 2600 V3 E5 2600 V4 E5 2600 V3 E5 2600 V4 E5 2600 V3 E5 2600 V4 4 Gb 8 Gb 1 2 V 1 2 V 1 2 V 1 2 V 1 2 V 1 2 V RDIMM SRx4 8 GB 16 GB 2133 2400 1866 2133 1600 1600 RDIMM SRx8 4 GB 8 GB 2133 2400...

Страница 64: ...1JNVI2C1 JI2C_EXP2 JNVI2C2 JIPMB1 BIOS LICENSE BAR CODE IPMI CODE REV 1 01 X10DSC X16 PCI E 3 0 CPU1 SIOM S SATA3 TPM PORT80 USB2 3 0 S SATA0 S SATA1 CPU2 SLOT1 PCI E 3 0 X8 CPU2 SLOT2 PCI E 3 0 X16 C...

Страница 65: ...orm Module Port 80 Header IPMI_LAN Dedicated IPMI LAN P1_NVMe 0 3 NVM Express PCI E 3 0 x4 Ports from CPU1 S SATA 0 3 SAS 3 0 Ports S SATA 1 2 support SMCI SuperDOM with built in power pins S SGPIO 1...

Страница 66: ...re LED_C1 C3 CPU1 Memory Fail LED for DIMMs C1 C3 On Memory Failure LED_D1 D3 CPU1 Memory Fail LED for DIMMs D1 D3 On Memory Failure LED_E1 E3 CPU2 Memory Fail LED for DIMMs E1 E3 On Memory Failure LE...

Страница 67: ...n the right for pin definitions Required Connection 12V 8 pin Power Pin Definitions Pins Definition 1 4 Ground 5 8 12V Caution To provide adequate power supply to the motherboard be sure to connect JP...

Страница 68: ...ttaches to the reset switch on the computer chassis See the table on the right for pin definitions Power Button The Power On connection is on pins 1 and 2 of JF1 These should be connected to the chass...

Страница 69: ...HDD LED Pin Definitions JF1 Pin Definition 13 UID Switch 14 HD Active NIC2 JLAN2 LED The LED connections for LAN2 are on pins 9 and 10 of JF1 Attach an LED cable to display network activity See the ta...

Страница 70: ...NMI Button Pin Definitions JF1 Pin Definition 19 Control 20 Ground Fan Header Pin Definitions FAN1 8 Pin Definition 1 Ground Black 2 12V Red 3 Tachometer 4 PWR Modulation Power On LED The Power On LE...

Страница 71: ...n Pin Definition 1 NC 2 NC 3 Ground 4 DATA Out 5 Load 6 Ground 7 Clock 8 NC NC No Connection Serial Ports One serial port COM1 is located at the rear of the server as part of the rear I O panel IPMB A...

Страница 72: ...connectors for SAS3 health monitoring and system management Power Supply SMBus I2 C Header The power System Management Bus header at JPI2 C1 is used to monitor the status of the power supply fan and...

Страница 73: ...te at http www supermicro com UID Switch Pin Definition 1 Ground 2 Ground 3 Button In 4 Ground UID LED Status Color State Status Blue On Unit Identified SMB I2 C for LCD Connector The connector used f...

Страница 74: ...1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS To clear CMOS 1 F...

Страница 75: ...firmware from a host server in order to modify system settings See the table on the right for jumper settings Watch Dog Enable Disable Jumper JWD controls the Watch Dog function Watch Dog is a system...

Страница 76: ...reen Blinking BMC Normal HDD LED Indicator States Color State Definition Green Blinking HDDs Normal BMC Heartbeat LED A BMC Baseboard Management Controller Heartbeat LED is located at BMC_HB_LED1 When...

Страница 77: ...M module installed on the memory slot that carries the same name For example if LED_A1 is on it indicates that an error has occurred to the DIMM module installed on the P1 DIMMA1 memory slot See the t...

Страница 78: ...e with non Supermicro SATADOMs that require an external power supply Note2 For more information on SATA HostRAID configuration please refer to the Intel SATA HostRAID User s Guide posted on our websit...

Страница 79: ...bsite at http www supermicro com products Find the product page for your motherboard here where you may download individual drivers and utilities After creating a CD DVD with the ISO files insert the...

Страница 80: ...versions and can be used with Nagios to maximize your system monitoring needs With SuperDoctor 5 Management Server SSM Server you can remotely control power on off and reset chassis intrusion for mul...

Страница 81: ...y in any way a damaged battery may release hazardous materials into the environment Do not discard a used battery in the garbage or a public landfill Please comply with the regulations set up by your...

Страница 82: ...5 28 SuperStorage Server 2028R NR48N Notes...

Страница 83: ...only tool required is a Phillips screwdriver Review the warnings and precautions listed in the manual before setting up or servicing this chassis These include information in Chapter 2 Warning Statem...

Страница 84: ...ved from the system 1 Use the operating system to power down the node following the on screen prompts 2 After the system has completely shut down carefully grasp the head of the power cord and gently...

Страница 85: ...ns while the server continues to operate Removing the Mid chassis Cover Remove the two screws securing each side of the cover push in the tabs then lift the cover Caution Do not operate the for long p...

Страница 86: ...rStorage Server 2028R NR48N 6 4 Rear Cover Removing the Rear Cover Remove the thumbscrew at the rear of the chassis then slide the cover to the rear and off Figure 6 4 Removing the Rear Cover Remove S...

Страница 87: ...e level SSDs and hard disk drives are recommended for use in Supermicro servers For information on recommended drives visit the Supermicro website Drive Connections NVMe drive slot numbers 0 23 are at...

Страница 88: ...ive bays Each drive carrier has two LED indicators These are described in Chapter 3 Removing Drive Carriers from the Chassis 1 To access mid chassis drives open the mid chassis cover and lift the driv...

Страница 89: ...and so that the mounting holes in the drive align with those in the carrier 4 Secure the drive to the carrier with the four screws included with the drive 5 Insert the drive and carrier into its bay v...

Страница 90: ...s of time such as swapping hard drives do not operate the server with the hard drive bays empty Installing Rear Hard Drives The two drives in the rear of the chassis are installed in the same way as t...

Страница 91: ...lot shield in the PCI slot that you wish to use 3 Slide the expansion card bracket into the open PCI slot while plugging the expansion card into the motherboard 4 Secure the expansion card bracket int...

Страница 92: ...le retaining screw to remove the cover Figure 6 11 SIOM Card Position on Chassis Rear 3 Position the card with its cover bracket in front of the SIOM slot and gently push in both sides of the card unt...

Страница 93: ...res changing Never run the server for an extended period of time with the chassis open 2 Open the mid chassis cover as described in Sections 6 3 3 Press the fan release tab to lift the failed fan from...

Страница 94: ...SuperStorage Server 2028R NR48N 6 12 Figure 6 14 Placing the System Fan...

Страница 95: ...Installing the Air Shroud 1 Power down the system as described in Section 5 2 Remove the covers as described in Section 5 3 2 Place the air shroud in the chassis The air shroud fits just behind the fi...

Страница 96: ...r 180 240v An amber light will be illuminated on the power supply when the power is off An illuminated green light indicates that the power supply is operating Changing the Power Supply 1 Unplug the A...

Страница 97: ...reserved for informational text When an option is selected in the left frame it is highlighted in white Often informational text will accompany it Note The AMI BIOS has default informational messages...

Страница 98: ...to the system In no event shall the manufacturer be liable for direct indirect special incidental or consequential damage arising from a BIOS update If you have to update the BIOS do not shut down or...

Страница 99: ...te This item displays the date that the BIOS setup utility was built CPLD Complex Programmable Logic Device Version This item displays the CPLD version used in the system Memory Information Total Memo...

Страница 100: ...IOS timing setting may cause the system to malfunction When this occurs restore the setting to the manufacture default setting Boot Feature Quiet Boot Use this item to select the screen display betwee...

Страница 101: ...ow the BIOS to automatically reboot the system from an EFI boot device after the initial boot failure Select Legacy Boot to allow the BIOS to automatically reboot the system from a Legacy boot device...

Страница 102: ...re CPU settings Processor Socket Processor ID Processor Frequency Processor Max Ratio Processor Min Ratio Microcode Revision L1 Cache RAM L2 Cache RAM L3 Cache RAM CPU 1 Version CPU 2 Version Clock Sp...

Страница 103: ...e and Enable Adjacent Cache Prefetch Available when supported by the CPU Select Enable for the CPU to prefetch both cache lines for 128 bytes as comprised Select Disable for the CPU to prefetch both c...

Страница 104: ...d Power Management Configuration Advanced Power Management Configuration Power Technology Select Energy Efficient to support power saving mode Select Custom to customize system power settings Select D...

Страница 105: ...e frequency to reduce power consumption and heat dissipation The options are Disable and Enable Turbo Mode Select Enable to use the Turbo Mode to boost system performance The options are Enable and Di...

Страница 106: ...ng CPU s clock cycle and voltage during a Halt State The options are Disable and Enable CPU T State Control Available when Power Technology is set to Custom ACPI Advanced Configuration Power Interface...

Страница 107: ...by the user The options are Gen 1 Generation 1 2 5 GT s Gen 2 Generation 2 5 GT s and Gen 3 Generation 3 8 GT s IIO1 Port 2C Link Speed This item configures the link speed of a PCI E port specified by...

Страница 108: ...by the user The options are x4x4x4x4 x4x4x8 x8x4x4 x8x8 x16 and Auto IIO2 Port 3A Link Speed This item configures the link speed of a PCI E port specified by the user The options are Gen 1 Generation...

Страница 109: ...rt to enhance system performance The options are Enable and Disable QPI Quick Path Interconnect Configuration QPI General Configuration QPI Status The following information will display Number of CPU...

Страница 110: ...configure Integrated Memory Controller IMC settings Enforce POR Select Enabled to enforce POR restrictions on DDR4 frequency and voltage programming The options are Enabled and Disabled Memory Frequen...

Страница 111: ...formance The options are Independent Mirror and Lockstep Mode Memory Rank Sparing Select Enable to enable memory sparing support for memory ranks to improve memory performance The options are Disabled...

Страница 112: ...ill display USB Configuration USB Module Version USB Controllers USB Devices Legacy USB Support Select Enabled to support onboard legacy USB devices Select Auto to disable legacy support when there ar...

Страница 113: ...or should be enabled for EHCI support The options are Disabled and Enabled XHCI Pre Boot Driver Select Enabled to load Intel XHCI pre boot driver The settings are Enabled and Disabled sSATA Configurat...

Страница 114: ...thout shutting down the system The options are Enabled and Disabled sSATA Port 0 Port 3 Spin Up Device On an edge detect from 0 to 1 set this item to allow the PCH to start a COMRESET initialization t...

Страница 115: ...se note that the option Both is not supported by the Windows Server 2012 R2 OS The options are Both SATA Controller and sSATA Controller sSATA Port 0 Port 3 Hot Plug Select Enabled to enable hot plugg...

Страница 116: ...ress The options are Enabled and Disabled SR IOV Available if the system supports Single Root Virtualization Select Enabled for Single Root IO Virtualization support The options are Enabled and Disabl...

Страница 117: ...using a device installed on the slot specified by the user The options are Disabled Legacy and EFI NVMe1 OPROM NVMe2 OPROM NVMe3 OPROM NVMe4 OPROM Select EFI to enable Option ROM support to boot the...

Страница 118: ...AST2400 Serial Port 1 Configuration Serial Port 1 Select Enabled to enable the onboard serial port specified by the user The options are Enabled and Disabled Device Settings This item displays the ba...

Страница 119: ...ts Per second Use this item to set the transmission speed for a serial port used in Console Redirection Make sure that the same speed is used in the host computer and the client computer A lower trans...

Страница 120: ...isplayed on a terminal and send it as text messages to a remote server The options are Disabled and Enabled Resolution 100x31 Select Enabled for extended terminal resolution support The options are Di...

Страница 121: ...8 Bits Per second Use this feature to set the transmission speed for a serial port used in Console Redirection Make sure that the same speed is used in the host computer and the client computer A lowe...

Страница 122: ...splayed on a terminal and send it as text messages to a remote server The options are Disabled and Enabled Resolution 100x31 Select Enabled for extended terminal resolution support The options are Dis...

Страница 123: ...s are COM1 Console Redirection and SOL Console Redirection Terminal Type Use this feature to select the target terminal emulation type for Console Redirection Select VT100 to use the ASCII character s...

Страница 124: ...the system boots until you reach the BIOS screen 2 You will be presented with the BIOS setup main screen Using the arrow keys navigate to the Advanced tab From there navigate down and select the CPU...

Страница 125: ...ACPI Settings WHEA Support Select Enabled to support the Windows Hardware Error Architecture WHEA platform and provide a common infrastructure for the system to handle hardware errors within the Windo...

Страница 126: ...CSI Initiator which is a unique name used in the world The name must in the IQN format The following submenu will be available for configuration Add an Attempt Delete Attempts Change Attempt Order 7 4...

Страница 127: ...S event log when the event log is full Select Do Nothing for the system to do nothing when the SMBIOS event log is full The options are Do Nothing and Erase Immediately SMBIOS Event Log Standard Setti...

Страница 128: ...rasing Settings Erase SEL Select Yes On next reset to erase all system event logs upon next system reboot Select Yes On every reset to erase all system event logs upon each system reboot Select No to...

Страница 129: ...S will search for a DHCP Dynamic Host Configuration Protocol server attached to the network and request the next available IP address for this computer The options are DHCP and Static Station IP Addre...

Страница 130: ...e options are Setup and Always Administrator Password Use this feature to set the administrator password which is required before entering the BIOS setup utility The length of the password should be f...

Страница 131: ...ment Provision Factory Default Keys Select Enable to install all manufacturer default keys for the following system security settings The options are Disabled and Enabled Enroll All Factor Default Key...

Страница 132: ...whose names appear on the list Forbidden Signatures This feature allows the user to set and save the forbidden signatures and deny the access to those whose names appear on the list Authorized TimeSta...

Страница 133: ...em to select the type of device to be used for system boot The options are Legacy UEFI and Dual Fixed Boot Order Priorities This option prioritizes the order of bootable devices from which the system...

Страница 134: ...Use this feature to create a new path for boot option Boot Option File Path Use this feature to set a new file path for boot option Create Use this feature to create a new boot option for the new dev...

Страница 135: ...r the new system configuration parameters to take effect Select Yes and press Enter to save the changes you ve made and reboot the system Save Options Save Changes When you have completed the system c...

Страница 136: ...estore User Defaults Select this item and press Enter to retrieve the user defined default settings that were previously saved to be used as current default settings Boot Override This feature allows...

Страница 137: ...fatal errors are usually communicated through a series of audible beeps The numbers on the fatal error list correspond to the number of beeps for the corresponding error X10 Serverboard BIOS Error Be...

Страница 138: ...SuperStorage Server 2028R NR48N A 2 Notes...

Страница 139: ...off control to a computer system at bootup B 2 How to Recover the UEFI BIOS Image the Main BIOS Block A UEFI BIOS flash chip consists of a recovery BIOS block and a main BIOS block a main BIOS image T...

Страница 140: ...website at www supermicro com to download the BIOS image into a USB flash device and rename it Super ROM for BIOS recovery use 2 Insert the USB device that contains the new BIOS image Super ROM into y...

Страница 141: ...want to start with BIOS recovery If you decide to proceed with BIOS recovery follow the procedures below 5 When the screen as shown above displays using the arrow key select the item Proceed with flas...

Страница 142: ...mpt Note Do not interrupt this process until BIOS flashing is completed 9 After seeing the message that BIOS update is completed unplug the AC power cable from the power supply to clear the CMOS and t...

Страница 143: ...Capacity Twenty four DIMM slots that can support ECC LRDIMM Load Reduced or ECC Registered RDIMM DDR4 2400 2133 1866 1600 memory Drive Bays Forty eight hot swap drive bays to house 2 5 NVMe SSD drives...

Страница 144: ...s with PMbus 12V Max 83 3A and Min 0A 100Vac 127Vac Max 133A and Min 0A 200Vac 240Vac 12V SB Max 2 1A and Min 0A Operating Environment Operating Temperature 10 C to 35 C 50 F to 95 F Non Operating Tem...

Страница 145: ...fornia Best Management Practices Regulations for Perchlorate Materials This Perchlorate warning applies only to products containing CR Manganese Dioxide Lithium coin cells Perchlorate Material special...

Страница 146: ...orm be reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro dis claims any and all liability and should buyer use or sell such pro...

Отзывы: