45
Chapter 3: Maintenance and Component Installation
as shown in above BMC GUI screen shot, the target eDsFF long drive is in slot 22, with
its Vendor/Model/serial matching what we probed.
Besides the slot labeling on the drive tray, the slot physical position could also be located
through the locate function in the BMC GUI (as shown above). When located, the slot
leD will blink reD.
3. Prepare the target eDsFF long drive for hot removal. On the BMC GUI, once the
eDsFF long (e1.l) drive
has been correctly identified, click the Eject button for its slot
to remove it from the Os:
2. Find the slot information of the target eDsFF long (e1.l) drive. In the server BMC GUI
(under server Health/nVMe ssD), the probed target nVMe ssD information can be
used find its slot location in the enclosure: