![Supermicro SuperStorage 1029P-NEL32R Скачать руководство пользователя страница 142](http://html1.mh-extra.com/html/supermicro/superstorage-1029p-nel32r/superstorage-1029p-nel32r_user-manual_1404776142.webp)
142
superserver 1029P-nel32r User's Manual
Figure E-3. Created Volume
without
enabling RAID spanned over VMD
controller
Figure E-4. Created Volume
with
enabling RAID spanned over VMD
controller
6.
Press [F4] to save the configuration and reboot the system.
7. Press [Del] to enter BIOs.
8. switch to
Advanced > Intel® Virtual RAID on CPU > All Intel VMD Controllers >
Create RAID Volume
.
9. set
Name
.
10. set
RAID Level
.
11. If cross-controller raID is required, select
Enable RAID spanned over VMD Controller
as shown in Figure e-4.
12.
Select specific disks for RAID with an [X].
•
raID0: select at least two [2 - 24] disks
•
raID1: select only two disks
•
raID5: select at least three [3 - 24] disks
•
raID10: select only four disks
13. select
Strip Size
(Default 64KB).
14. select
Create Volume
.
15. If another raID is needed, start again at step 6.