Chapter 3: System Interface
3-3
1
2
NIC1 LED
Indicates network activity on the LAN1 port when
fl
ashing.
NIC2 LED
Indicates network activity on the LAN2 port when
fl
ashing.
HDD LED
This indicates the IDE channel activity. It also indicates SAS/SATA drive, SCSI drive,
and/or DVD-ROM drive activity when
fl
ashing.
Power Fail LED
This indicates a power failure to the system's power supply units.
Universal Information LED
See the following table for the status shown by this LED.
Universal Information LED
Status
Description
Continuously on and red
An overheat condition has occurred. (This may be caused by cable congestion.)
Blinking red (1 Hz)
Fan failure: check for an inoperative fan.
Blinking red (0.25 Hz)
Power failure: check for an inoperative power supply.
Solid blue
Local UID has been activated. Use this function to locate the server in a rack
environment.
Blinking blue (300 msec)
Remote UID has been activated. Use this function to locate the server from a
remote location.