background image

Chapter 7: BIOS

7-37

Secure Boot Menu 

Secure Boot

Select Enable for secure boot support to ensure system security at bootup. The 
options are Enabled and Disabled.

Secure Boot Mode

This feature allows the user to select the desired secure boot mode for the system. 
The options are Standard and Custom.

Key Management

Default Keys Provision

Select Enable to install all manufacture defaults for the following system security 
settings. The options are Disabled and 

Enabled

.

Enroll All Factory Default Keys

This feature allows the user to store security-related boot data in a file of the same 

named in the system root folder of your computer.

Save All Secure Boot Variables

This feature allows the user to save the secure boot settings specified by the user.

Platform Key (PK)

Delete PK

Select <Yes> to confirm deletion of the Platform Key (PK) from the system.

Set New Key

Select <Yes> to load the manufacture_default platform keys for your system. Select 
No to load the default settings from other sources.

Key Exchange Key (KEK)

Delete KEK (Key Exchange Key)

Select <Yes> to confirm deletion of the KEK from the system.

Set New KEK (Key Exchange Key)

Select <Yes> to confirm that a new KEK will be set in the  system.

Содержание SuperServer 6048R-TXR

Страница 1: ...SUPERSERVER 6048R TXR USER S MANUAL 1 0...

Страница 2: ...f any such disputes Super Micro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and found to comply with the limit...

Страница 3: ...ssary to install the system into a rack and check out the server configuration prior to powering up the system If your server was ordered without the processor and memory components this chapter will...

Страница 4: ...low the procedures given in this chapter when installing removing or reconfiguring SATA or peripheral drives and when replacing system power supply units and cooling fans Chapter 7 BIOS The BIOS chapt...

Страница 5: ...v Preface Notes...

Страница 6: ...em 2 1 2 3 Preparing for Setup 2 1 Choosing a Setup Location 2 1 2 4 Warnings and Precautions 2 2 Rack Precautions 2 2 Server Precautions 2 2 Rack Mounting Considerations 2 3 Ambient Operating Tempera...

Страница 7: ...lation 4 8 Restricted Area 4 9 Battery Handling 4 10 Redundant Power Supplies 4 12 Backplane Voltage 4 13 Comply with Local and National Electrical Codes 4 14 Product Disposal 4 15 Hot Swap Fan Warnin...

Страница 8: ...2 6 3 Accessing the Inside of the System 6 3 6 4 System Fans 6 4 System Fan Failure 6 4 Installing the Rear Exhaust Fans 6 4 6 5 Drive Bay Installation Removal 6 5 Hot Swap Drive Bays 6 5 Installing...

Страница 9: ...xhaust fans FAN 0082L4 One 9 cm front intake fan FAN 0097L4 Two active CPU heatsinks SNK P0048AP4 SATA accessories One HDD backplane BPN SAS 842TQ Five 3 5 hard disk drive trays MCP 220 00075 0B Note...

Страница 10: ...3 0 subsystem which is RAID 0 1 5 and 10 supported The I SATA0 through I SATA5 ports are supported by the Intel PCH while the S SATA0 through S SATA0 3 ports are supported by the Intel SCU The SATA d...

Страница 11: ...rives are hot swappable units and are connected to a backplane that provides power and control Three additional 5 25 drive bays are included which are not hot swappable Front Control Panel The control...

Страница 12: ...0 USB2 0 PCIE 3 0 x8 5 PCIE 2 0 x4 1 x8 5 PCIE3 0 x8 Slots 6 7 8 9 10 PCIE2 0 x8 Slots 11 x4 CPU REAR CPU FRONT QPI DDR4 DIMM DDR4 DIMM DDR4 DIMM DDR4 DIMM DDR4 DIMM DDR4 DIMM DDR4 DIMM QPI 9 6GT s PC...

Страница 13: ...e Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro...

Страница 14: ...1 6 SUPERSERVER 6048R TXR User s Manual Notes...

Страница 15: ...itable location for the rack unit that will hold the SuperServer 6048R TXR It should be situated in a clean dust free area that is well ventilated Avoid areas where heat electrical noise and electroma...

Страница 16: ...her Always make sure the rack is stable before extending a component from the rack You should extend only one component at a time extending two or more si multaneously may cause the rack to become uns...

Страница 17: ...le overloading of circuits might have on overcurrent protection and power supply wiring Appropriate consideration of equipment nameplate ratings should be used when addressing this concern Reliable Gr...

Страница 18: ...s into a Telco type rack use one L shaped bracket on either side of the chassis two total First determine how far follow the server will extend out the front of the rack Larger chassis should be posit...

Страница 19: ...il System Overview This section provides information on installing the SC842 chassis into a four post rack unit with the optional quick release rails There are a variety of rack units on the market wh...

Страница 20: ...er rail toward the front of the chassis 3 Secure the chassis with two screws as illustrated Repeat steps 1 and 2 for the other inner rail 1 1 1 2 1 3 1 3 Warning In any instance of pulling the system...

Страница 21: ...smaller outer rail 3 Hang the hooks of the rails onto the rack holes and if desired use screws to secure the front of the outer rail onto the rack 4 Repeat steps 1 3 for the remaining outer rail Figu...

Страница 22: ...ide the inner rails into the outer rails keeping the pressure even on both sides When the chassis has been pushed completely into the rack it should click into the locked position 4 Optional screws ma...

Страница 23: ...of specific components There are also two buttons on the chassis control panel 3 2 Control Panel Buttons The two buttons located on the front of the chassis include a reset button and a power on off b...

Страница 24: ...be off when the system is operating normally NIC1 Indicates network activity on the LAN1 port when flashing NIC2 Indicates network activity on the LAN2 port when flashing Information LED This LED wil...

Страница 25: ...ystem is operating 3 4 Drive Carrier LEDs Each drive carrier has two LEDs Green When illuminated the green LED on the drive carrier indicates drive activity A connection to the backplane enables this...

Страница 26: ...SUPERSERVER 6048R TXR User s Manual 3 4 Notes...

Страница 27: ...nt for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis...

Страница 28: ...onsidere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontrar el...

Страница 29: ...l kan veroorzaken Voordat u aan enige apparatuur gaat werken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard proc...

Страница 30: ...e en des Systems an die Stromquelle die Installationsanweisungen lesen Advertencia Lea las instrucciones de instalaci n antes de conectar el sistema a la red de alimentaci n Attention Avant de branche...

Страница 31: ...erstromschutz installiert ist Stellen Sie sicher dass der Nennwert der Schutzvorrichtung nicht mehr als 250 V 20 A betr gt Advertencia Este equipo utiliza el sistema de protecci n contra cortocircuito...

Страница 32: ...e power cord removed from the power supply module s before accessing the chassis interior to install or remove system components 250V 20A Waarschuwing Dit product is afhankelijk van de kortsluitbeveil...

Страница 33: ...tado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me doit tre d branch de toutes les sourc...

Страница 34: ...nung Das Installieren Ersetzen oder Bedienen dieser Ausr stung sollte nur geschultem qualifiziertem Personal gestattet werden Advertencia Solamente el personal calificado debe instalar reemplazar o ut...

Страница 35: ...eug Schloss und Schl ssel oder einer sonstigen Sicherheitsvorkehrung m glich Advertencia Esta unidad ha sido dise ada para instalaci n en reas de acceso restringido S lo puede obtenerse acceso a una d...

Страница 36: ...me or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions Waarschuwing Dit apparaat is bedoeld voor installatie in gebieden met een b...

Страница 37: ...ecommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incorrecta Reemplazar la bat...

Страница 38: ...llen dass der Einheit kein trom zugef hrt wird m ssen alle Verbindungen entfernt werden Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por complet...

Страница 39: ...System in Betrieb ist treten auf der R ckwandplatine gef hrliche Spannungen oder Energien auf Vorsicht bei der Wartung Advertencia Cuando el sistema est en funcionamiento el voltaje del plano trasero...

Страница 40: ...Installation der Ger te muss den Sicherheitsstandards entsprechen Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigh...

Страница 41: ...onal laws and regulations Advertencia La instalacion del equipo debe cumplir con las normas de electricidad locales y nacionales Attention L quipement doit tre install conform ment aux normes lectriqu...

Страница 42: ...ge de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Warning The fans might still be t...

Страница 43: ...tfernt Advertencia Los ventiladores podran dar vuelta cuando usted quite ell montaje del ventilador del chasis Mandtenga los dedos los destornilladores y todos los objetos lejos de las aberturas del v...

Страница 44: ...CSA Supermicro UL CSA UL CSA Warnung Bei der Installation des Produkts die zur Verf gung gestellten oder benannt Anschlusskabel Stromkabel und Netzteile Verwendung anderer Kabel und Adapter kann zu ei...

Страница 45: ...s dispositivos el ctricos que los productos designados por Supermicro solamente Attention Lors de l installation du produit utilisez les bables de connection fournis ou d sign L utilisation d autres c...

Страница 46: ...els stroomkabels en adapters Het gebruik van andere kabels en adapters kan leiden tot een storing of een brand Elektrisch apparaat en veiligheidsinformatiebladen wet verbiedt het gebruik van UL of CSA...

Страница 47: ...chapter To prevent the serverboard from bending keep one hand under the center of the board to support it when handling The following measures are generally sufficient to protect your equipment from e...

Страница 48: ...the cables do not come into contact with the fans Connecting Power Cables The X10DRX has a 24 pin proprietary power supply connector JPWR1 for connection to the ATX power supply In addition there are...

Страница 49: ...Pins 5 3 I O Ports The I O ports are color coded in conformance with the PC 99 specification See Figure 5 2 below for the colors and locations of the various I O ports 1 1 1 7 1 5 1 6 1 4 1 3 1 2 1 8...

Страница 50: ...dding re moving or changing any hardware components Make sure that you install the processor into the CPU socket before you install the CPU heatsink If you buy a CPU separately make sure that you use...

Страница 51: ...remove the WARNING plastic cap from the socket 5 Use your thumb and index finger to hold the CPU by its edges Align the CPU keys which are semi circle cutouts against the socket keys 6 Once they are a...

Страница 52: ...e check that the CPU is aligned properly 7 With the CPU in the socket inspect the four corners of the CPU to make sure that they are flush with the socket 8 Close the load plate Lock the lever labeled...

Страница 53: ...ready been applied 2 Place the heatsink on top of the CPU so that the four mounting holes are aligned with those on the serverboard and the heatsink bracket underneath 3 Screw in two diagonal screws i...

Страница 54: ...the CPU or the CPU socket 1 Unscrew the heatsink screws from the serverboard in the sequence as shown in the illustration below 2 Gently wriggle the heatsink to loosen it from the CPU Do not use exces...

Страница 55: ...tabs outwards on both ends of the DIMM slot to unlock 3 Insert each DIMM module vertically into its slot Pay attention to the notch along the bottom of the module to avoid installing incorrectly see...

Страница 56: ...le For memory to work properly please follow the instructions below 1 CPU 2 DIMMs CPU1 P1 DIMMA1 P1 DIMMB1 1 CPU 4 DIMMs CPU1 P1 DIMMA1 P1 DIMMB1 P1 DIMMC1 P1 DIMMD1 1 CPU 5 8 DIMMs CPU1 P1 DIMMA1 P1...

Страница 57: ...eviously removed from the chassis 8 Repeat this process with each PCI card you want to install into the chassis INTEL CONFIDENTIAL Intel and the Intel logo are trademarks or registered trademarks of I...

Страница 58: ...5 12 SUPERSERVER 6048R TXR User s Manual Press the Middle of the Release Tab Lift the Release Tab Figure 5 7 Add on Card Expansion Card Port...

Страница 59: ...Port80 Front CTRL Panel JF1 USB 2 3 2 0 USB 7 8 3 0 S SATA0 S SATA1 S SATA2 S SATA3 I SATA0 I SATA2 I SATA1 I SATA3 I SATA5 I SGPIO1 I SGPIO2 S SGPIO1 JL1 I SATA4 FANA JSD2 JSD1 JBT1 JBAT1 Battery BIO...

Страница 60: ...in ATX Main Power Connector JPWR2 3 12V 8 pin Power Connectors JPWR4 12V 4 pin Power Connector I SATA0 5 SATA 3 0 Ports supported by Intel PCH I SATA4 I SATA5 support SuperDOMs with power pins built i...

Страница 61: ...V 14 12V 2 3 3V 15 COM 3 COM 16 PS_ON 4 5V 17 COM 5 COM 18 COM 6 5V 19 COM 7 COM 20 Res NC 8 PWR_OK 21 5V 9 5VSB 22 5V 10 12V 23 5V 11 12V 24 COM 12 3 3V Required Connections 12V 8 pin PWR Pin Definit...

Страница 62: ...y Fail Overheat OH Fan Fail PWR Fail UID LED Connect an LED cable to pins 7 and 8 of Front Control Panel to use the Overheat Fan Fail Power Fail and UID LED connections The red LED on pin 8 provides w...

Страница 63: ...s COM1 COM2 are provided on the serverboard COM1 is located on the rear I O panel COM2 located close to PCI E slot1 provides front access support See the table on the right for pin definitions Etherne...

Страница 64: ...rial Bus USB Two USB 3 0 USB 4 5 and two USB 2 0 ports USB 0 1 are located on the rear I O panel A Type A USB connector USB 6 and a USB header with two USB connections USB 7 8 provide a total of three...

Страница 65: ...in definitions Internal Buzzer SP1 Pin Definition Pin Definitions Pin 1 Pos Beep In Pin 2 Neg Alarm Speaker TPM Header Port 80 Header A Trusted Platform Module Port 80 header is located at JTPM1 to pr...

Страница 66: ...s on the right for more information I SGPIO1 2 S SGPIO1 Headers Pin Definitions Pin Definition Pin Definition 1 NC 2 NC 3 Ground 4 Data 5 Load 6 Ground 7 Clock 8 NC Power SMB I2 C Connector The Power...

Страница 67: ...2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS To clear CMOS 1...

Страница 68: ...on the right for jumper settings Watch Dog must also be enabled in BIOS Note When enabled the user needs to write their own application software in order to disable the Watch Dog Timer Watch Dog Jumpe...

Страница 69: ...ate the speed of the connection See the tables at right for more information 5 10 Onboard Indicators GLAN Link Indicator LED Settings LED Color Definition Off No Connection or 10 Mbps Green 100 Mbps A...

Страница 70: ...TA0 5 are supported by the Intel PCH and S SATA0 3 are supported by the Intel SCU I SATA4 5 can be used with Supermicro SuperDOMs These are yellow SATA DOM connectors with power pins built in and so d...

Страница 71: ...ctory and locate the ISO file for your serverboard Download this file to create a CD DVD of the drivers and utilities it contains You may also use a utility to extract the ISO file if preferred Anothe...

Страница 72: ...nt versions and can be used with Nagios to maximize your system monitoring needs With SuperDoctor 5 Management Server SSM Server you can remotely control power on off and reset chassis intrusion for m...

Страница 73: ...y in any way a damaged battery may release hazardous materials into the environment Do not discard a used battery in the garbage or a public landfill Please comply with the regulations set up by your...

Страница 74: ...5 28 SUPERSERVER 6048R TXR User s Manual Notes...

Страница 75: ...o prevent damage to any printed circuit boards PCBs it is important to handle them very carefully The following measures are generally sufficient to protect your equipment from ESD damage Precautions...

Страница 76: ...dled these wires together to simplify the connection Connect the cable from JF1 on the serverboard to the Control Panel PCB printed circuit board Make sure the red wire plugs into pin 1 on both connec...

Страница 77: ...the system has been installed to a rack carefully pull it out on the rails until the top cover is exposed Powered must be removed from the system before working on or replacing some components refer t...

Страница 78: ...p up to full speed and the overheat fan fail LED on the control panel will turn on Replace any failed fan at your earliest convenience with the same type and model the system can continue to run with...

Страница 79: ...es plug into a backplane that provides power drive ID and bus ter mination A RAID controller can be used with the backplane to provide data security Removing a Hard Drive Carrier 1 Press the release b...

Страница 80: ...into the carrier with the printed circuit board side facing down 5 Carefully align the mounting holes in the hard drive and the carrier Make sure the bottom of the hard drive and bottom of the hard d...

Страница 81: ...chassis remove the mini bezel from the drive bay The mini bezel is the small grating that covers the drive bay Remove this by simply pulling it out of the bay 3 If replacing an existing drive remove...

Страница 82: ...Replacing the Power Supply You do not need to shut down the system to replace a power supply unit The backup power supply module will keep the system up and running while you replace the failed hot s...

Страница 83: ...Chapter 6 Advanced Chassis Setup 6 9 Figure 6 5 Replacing a Power Supply Module Release Button 1 1 1 2...

Страница 84: ...6 10 SUPERSERVER 6048R TXR User s Manual Notes...

Страница 85: ...ve the key legend is an area reserved for a text message When an option is selected in the left frame it is highlighted in white Often a text message will accompany it Note The AMI BIOS has default te...

Страница 86: ...e manufacturer be liable for direct indirect special incidental or consequential damage arising from a BIOS update If you have to update the BIOS do not shut down or reset the system while the BIOS is...

Страница 87: ...lays the date that the BIOS setup utility was built Memory Information Total Memory This displays the amount of memory that is available in the system Memory Speed This displays the detected system me...

Страница 88: ...Enabled INT19 Interrupt 19 Trap Response Interrupt 19 is the software interrupt that handles the boot disk function When this item is set to Immediate the ROM BIOS of the host adaptors will capture In...

Страница 89: ...ect Power On for the system power to be turned on after a power outage Select Last State to allow the system to resume its last state before a power outage The options are Power On Stay Off and Last S...

Страница 90: ...k The options are Enable and Disable Refer to Intel and Microsoft websites for more information PPIN Control Select Unlock Enable to use the Protected Processor Inventory Number PPIN in the system The...

Страница 91: ...le operating systems and applications in independent parti tions creating multiple virtual systems in one physical computer The options are Enable and Disable Note If a change is made to this setting...

Страница 92: ...the Turbo Mode to boost system performance The options are Enable and Disable P State Coordination This feature determines how an ACPI aware operating system will coordinate P State transitions betwe...

Страница 93: ...m to reduce power consumption The options are Enable and Disable Chipset Configuration North Bridge This feature allows the user to configure the following North Bridge settings IIO Configuration EV D...

Страница 94: ...E port speci fied by the user The options are x4x4x4x4 x4x4x8 x8x4x4 x8x8 x16 and Auto CPU1 SLOT4 PCI E 3 0 x8 Link Speed This item configures the link speed of a PCI E port specified by the user The...

Страница 95: ...Generation 2 5 GT s and Gen 3 Generation 3 8 GT s IOU1 II02 PCIE Port 3 Use this item to configure the PCI E port Bifuraction setting for a PCI E port speci fied by the user The options are x4x4x4x4 x...

Страница 96: ...support for Direct I O VT d support by reporting the I O device assignments to the VMM Virtual Machine Monitor through the DMAR ACPI Tables This feature offers fully protected I O resource sharing acr...

Страница 97: ...U support this feature Select Enable for Early Snoop support to enhance system performance The options are Enable Disable and Auto Isoc Mode Select Enable to enable Isochronous support to meet QoS Qua...

Страница 98: ...processor idle states The options are Disabled and CLTT Closed Loop Thermal Throttling A7 Mode Select Enable to support A7 Addressing mode to improve memory performance The options are Enable and Disa...

Страница 99: ...nd on a memory module When the CPU or I O issues a demand read command and the read data from memory turns out to be a correctable error the error is corrected and sent to the requestor the original s...

Страница 100: ...re Disabled and Enabled EHCI2 Select Enabled to enable EHCI Enhanced Host Controller Interface support on USB 2 0 connector 2 at least one USB 2 0 connector should be enabled for EHCI support The opti...

Страница 101: ...able a SATA port specified by the user The options are Disabled and Enabled Port 0 Port 5 Hot Plug Select Enabled to enable hot plugging support for a port specified by the user which will allow the u...

Страница 102: ...egacy to load a legacy driver for system boot The options are Disabled EFI and Legacy SATA sSATA RAID Boot Select Select SATA Controller to boot the system from a SATA RAID device Select sSATA Control...

Страница 103: ...Enabled and Disabled Configure sSATA as Select IDE to configure an sSATA drive specified by the user as an IDE drive Select AHCI to configure an sSATA drive specified by the user as an AHCI drive Sele...

Страница 104: ...SATA as is set to IDE the following items will display sSATA Port 0 Port 3 This item indicates that an sSATA port specified by the user is not installed or not detected Port 0 Port 3 sSATA Device Type...

Страница 105: ...are Disabled and Enabled sSATA Port 0 Port 3 Hot Plug Select Enabled to enable hot plugging support for a port specified by the user which will allow the user to replace a SATA disk drive installed on...

Страница 106: ...em supports Single Root Virtualization Select Enabled for Single Root IO Virtualization support The options are Enabled and Disabled Maximum Payload Select Auto for the system BIOS to automatically se...

Страница 107: ...gacy and EFI Onboard LAN Option ROM Type Select Enabled to enable Option ROM support to boot the computer using a device installed on the slot specified by the user The options are Legacy and EFI Onbo...

Страница 108: ...r Serial Port 1 are Auto IO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 and IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 The options for Serial Po...

Страница 109: ...its to detect data transmission errors Select Even if the parity bit is set to 0 and the number of 1 s in data bits is even Select Odd if the parity bit is set to 0 and the number of 1 s in data bits...

Страница 110: ...or disable legacy Console Redirection after BIOS POST When the option Bootloader is selected legacy Console Redirection is disabled before booting the OS When the option Always Enable is selected lega...

Страница 111: ...do not want to send a parity bit with your data bits in transmission Select Mark to add a mark as a parity bit to be sent along with the data bits Select Space to add a Space as a parity bit to be sen...

Страница 112: ...le legacy Console Redirection remains enabled upon OS boot The options are Always Enable and Bootloader Serial Port for Out of Band Management Windows Emergency Management Services EMS The submenu all...

Страница 113: ...The setting for each these features is displayed Data Bits Parity Stop Bits ACPI Settings WHEA Support Select Enabled to support the Windows Hardware Error Architecture WHEA plat form and provide a co...

Страница 114: ...Please reboot your system for any change on the TPM state to take effect The options are Disabled and Enabled Pending Operation Use this item to schedule a TPM related operation to be performed by a s...

Страница 115: ...support Runtime Error Logging The options are Enable and Dis able If this item is set to Enable the following item will be available for configuration Erasing Settings Erase Event Log Select Enabled t...

Страница 116: ...is 1 METW Multiple Event Count Time Window This item is used to determine how long in minutes should the multiple event counter wait before generating a new event log Enter a number between 0 to 99 T...

Страница 117: ...o configure Intelligent Platform Management Interface IPMI settings IPMI Firmware Revision This item indicates the IPMI firmware revision used in your system IPMI Status This item indicates the status...

Страница 118: ...to erase all system event logs upon each system reboot Select No to keep all system event logs after each system reboot The options are No Yes On next reset and Yes On every reset When SEL is Full Th...

Страница 119: ...MI BIOS will search for a DHCP Dy namic Host Configuration Protocol server attached to the network and request the next available IP address for this computer The options are DHCP Unspecified and Stat...

Страница 120: ...pt for a password at bootup and upon entering the BIOS setup utility The options are Setup and Always Administrator Password Use this feature to set the administrator password which is required before...

Страница 121: ...eys This feature allows the user to store security related boot data in a file of the same named in the system root folder of your computer Save All Secure Boot Variables This feature allows the user...

Страница 122: ...Delete DBT DataBase Timer Select Yes to confirm deletion of the database timer from the system Set New DBT DataBase Timer Select Yes to confirm that the new database timer will be set in the system Ap...

Страница 123: ...t The options are Legacy UEFI and Dual Fixed Boot Order Priorities This option prioritizes the order of bootable devices from which the system will boot Press Enter on each entry from top to bottom to...

Страница 124: ...TXR User s Manual Delete Boot Option Use this item to select a boot device to delete from the boot priority list Delete Boot Option Select the target boot device to delete Network Drive BBS Prioritie...

Страница 125: ...em configuration changes select this option to leave the BIOS setup utility and reboot the computer for the new system configura tion parameters to take effect Select Save Changes and Exit from the Ex...

Страница 126: ...s User Defaults from the Exit menu and press Enter to save changes to the BIOS setup for future use Restore User Defaults Select Restore User Defaults from the Exit menu and press Enter to retrieve us...

Страница 127: ...These fatal errors are usually communicated through a series of audible beeps The numbers on the fatal error list correspond to the number of beeps for the cor responding error BIOS Error Beep Codes B...

Страница 128: ...A 2 SUPERSERVER 6048R TXR User s Manual Notes...

Страница 129: ...ts that can support up to 1024 GB of LRDIMM or 512 GB of RDIMM DDR4 2133 1866 1600 memory Note See the memory section in Chapter 5 for details SATA Controller Intel on chip controller for 10 SATA 3 0...

Страница 130: ...re 40 to 60 C 40 to 140 F Operating Relative Humidity 8 to 95 non condensing Non operating Relative Humidity 5 to 95 non condensing Regulatory Compliance Electromagnetic Emissions FCC Class A EN 55022...

Страница 131: ...B 3 Appendix B System Specifications Notes...

Страница 132: ...rform be reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro dis claims any and all liability and should buyer use or sell such p...

Отзывы: