To load it from the external media, navigate to No and press
<Enter>
.
When the following screen appears, select the USB flash drive that contains the desired file.
Страница 1: ...USER S MANUAL Revision 1 0a SuperServer 6029TR DTR...
Страница 2: ...a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instruction manual may cause harmful i...
Страница 3: ...drivers utilities and the user s manual for your server Supermicro product manuals http www supermicro com support manuals Product drivers and utilities https www supermicro com wftp driver Product s...
Страница 4: ...Rack Precautions 16 Server Precautions 17 Rack Mounting Considerations 17 Ambient Operating Temperature 17 Airflow 17 Mechanical Loading 17 Circuit Overloading 18 Reliable Ground 18 2 3 Installing th...
Страница 5: ...rom the Motherboard 29 PCI Expansion Card Installation 30 Memory Installation 30 Memory Support 30 DIMM Installation 32 DIMM Removal 32 Motherboard Battery 33 Replacing the Battery 33 3 3 Chassis Comp...
Страница 6: ...ctor 5 59 5 4 IPMI 60 Chapter 6 BIOS 6 1 Introduction 61 6 2 Main Setup 62 6 3 Advanced Setup Configurations 64 6 4 Event Logs 92 6 5 IPMI 94 6 6 Security 97 6 7 Boot 100 6 8 Save Exit 103 Appendix A...
Страница 7: ...V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma supermic...
Страница 8: ...lease file a damage claim with the carrier who delivered it Decide on a suitable location for the rack unit that will hold the server It should be situated in a clean dust free area that is well venti...
Страница 9: ...to 1TB 3DS ECC RDIMM LRDIMM to speeds of DDR4 2666MHz in 8 DIMM slots 81xx 61xx 51xx 41xx 31xx series processors Chipset Intel C621 chipset Expansion Slots Two PCI E 3 0 x8 FH HL or one PCI E 3 0 x8 F...
Страница 10: ...linking blue 300 msec Remote UID has been activated Use this function to locate the server from a remote location 1 4 3 2 Control Panel Features Item Feature Description 1 Power Button The main power...
Страница 11: ...l Front control panel with LEDs and buttons see preceding page 2 HDD LED Indicates activity on a hard drive when flashing Figure 1 2 Chassis Front View Front Features The SC827HD R1K23BP3 is a 2U chas...
Страница 12: ...00W Titanium Level power supplies 5 Dedicated IPMI LAN Port A dedicated IPMI LAN port is located above USB0 1 6 USB 3 0 Ports Rear access USB 3 0 ports 2x 7 LAN Ports Accept RJ45 type cables 8 COM Por...
Страница 13: ...s pinout information and jumper settings refer to Chapter 4 IPMI CODE C A 1 BIOS LICENSE DESIGNED IN USA MAC CODE X11DPT L REV 1 01 CM P N BAR CODE P1 DIMMB1 P1 DIMMA1 CPU1 CPU2 PCH BMC LAN CTRL LAN C...
Страница 14: ...sk On Module devices JF1 Front Panel Control Signals and Power Input Connector JIPMB1 4 pin BMC External I2 C header for an IPMI supported card JSD1 JSD2 SATA DOM Power Connectors 1 2 JTPM1 Trusted Pl...
Страница 15: ...X1 G2 USB 2 0 2 USB2 0 PCH RTL8211E VB CG RJ45 BIOS ESPI LBG 1G X1 UPLINK 15W SPI Temp Sensor NCT7718W TPM HEADER USB SPI BIOS BMC AST2500 5 COM1 Connector VGA Connector BMC Boot Flash DDR4 PCI E X16...
Страница 16: ...k Please read this section in its entirety before you begin the installation Choosing a Setup Location The system should be situated in a clean dust free area that is well ventilated Avoid areas where...
Страница 17: ...from power surges and voltage spikes and to keep your system operating in case of a power failure Allow any drives and power supply modules to cool before touching them When not servicing always keep...
Страница 18: ...ention should be given to power supply connections other than the direct connections to the branch circuit i e the use of power strips etc To prevent bodily injury when mounting or servicing this unit...
Страница 19: ...ation instructions that came with the specific rack you are using Identifying the Rails The rack rails and the related hardware should have been included with the system Refer to Figure 2 1 to identif...
Страница 20: ...manner again keeping in mind that the rails are left right specific You will also need to attach the rail brackets when installng into a telco rack Note Both front chassis rails and the rack rails ha...
Страница 21: ...to the rack using the screws provided 2 Press the button where the two outer rails are joined to retract the smaller outer rail 3 Hang the hooks of the rails onto the rack holes and if desired use sc...
Страница 22: ...ng the inside of the rack and the rollers toward the front of the rack 2 Screw the assembly securely to the rack 3 Attach the other assembly to the other side of the rack making sure that both are at...
Страница 23: ...ssis four total 1 First determine how far the server will extend out from the front of the rack The chassis should be positioned so that the weight is balanced between front and back 2 Attach the two...
Страница 24: ...ply 1 Use the operating system to power down the system 2 After the system has completely shut down disconnect the AC power cord s from the power strip or outlet If your system has more than one power...
Страница 25: ...clip Also locate notch B and notch C on the processor clip 2 Locate pin 1 notch A which is the triangle on the substrate of the CPU Also locate notch B and notch C on the CPU as shown below 3 Align p...
Страница 26: ...sembly a in the graphic Note a larger hole and plastic mounting clicks located next to the hollow triangle Also locate another set of mounting clicks and Heatsink Upside Down 1 2 1 2 Remaining plastic...
Страница 27: ...late These components are pre installed on the motherboard before shipping CPU Socket w Dust Cover On Dusk Cover CPU Socket Removing the Dust Cover from the CPU Socket Remove the dust cover from the C...
Страница 28: ...acing the heatsink on top 3 With a T30 Torx bit screwdriver gradually tighten screws 1 4 to assure even pressure The order of the screws is shown on the label on top of the heatsink To avoid damaging...
Страница 29: ...escribed in Section 3 1 1 Using a T30 Torx bit screwdriver loosen and remove the screws on the PHM from the socket starting with the screw marked 4 in the sequence of 4 3 2 1 2 Pull up the PHM while r...
Страница 30: ...opulating the DIMM slots in a 1DPC one DIMMs per channel configuration with pairs of memory modules of the same type speed and size will result in interleaved memory which improves performance Check t...
Страница 31: ...GB 2666 RDIMM 3Ds QRX4 N A 2H 64GB 2666 RDIMM 3Ds 8RX4 N A 4H 128GB 2666 LRDIMM QRx4 32GB 64GB 2666 LRDIMM 3Ds QRX4 N A 2H 64GB 2666 8Rx4 N A 4H 128GB 2666 DDR4 Memory Support for 1 Slot Per Channel C...
Страница 32: ...rly please use memory modules of the same type and speed on the motherboard 2 Push the release tabs outwards on both ends of the DIMM slot to unlock it 3 Align the key of the DIMM module with the rece...
Страница 33: ...Replacing the Battery Begin by removing power from the system as described in Section 3 1 1 Push aside the small clamp that covers the edge of the battery When the battery is released lift it out of...
Страница 34: ...chassis The SATA drives are mounted in drive carriers to simplify their installation and removal from the chassis Both procedures may be done without removing power from the system Removing a Hot Swa...
Страница 35: ...cator and a status indicator In RAID configurations the status indicator lights to indicate the status of the drive In non RAID configurations the status indicator remains off See the table below for...
Страница 36: ...cooling It is very important that the chassis top cover is installed for the cooling air to circulate properly through the chassis and cool the components Installing Fans Fan speed is controlled by s...
Страница 37: ...fan header on the motherboard 7 Lift the failed fan from the chassis and pull it completely out 8 Place the new fan into the vacant space in the housing while making sure the arrows on the top of the...
Страница 38: ...SuperServer 6029TR DTR User s Manual 38 Figure 3 6 Replacing a System Fan in the Fan Housing...
Страница 39: ...f it is necessary to remove the backplane follow the instructions below Removing the Backplane 1 Power down and unplug the system from any power source 2 Remove the chassis cover 3 Disconnect the cabl...
Страница 40: ...kplane Mounting Bracket in the Floor of the Chassis Figure 3 9 Removing the Backplane from the Chassis 7 Loosen the six screws in the backplane mounting bracket located on the floor of the chassis 8 G...
Страница 41: ...angle pushing it up against the side of the chassis 4 Ease the backplane forward against the front of the chassis This will aid in the alignment of the mounting holes 5 Align the mounting holes in th...
Страница 42: ...nterfere with the air shroud placement 3 Place the air shroud in the chassis 4 Slide the air shroud into the grooves just behind the fan rack 5 Ensure the two tabs on the air shroud are fit in the pin...
Страница 43: ...handles at the rear of the node tray Push both of these inward 3 While pushing the latches inward grasp both handles and pull the node from the chassis 4 Perform any service needed to the node in a ti...
Страница 44: ...in the drawer and add and remove standoffs as needed 5 Secure the serverboard to the node drawer using the rounded Phillips head screws included for this purpose Do not exceed eight pounds of torque...
Страница 45: ...45 Chapter 3 Maintenance and Component Installation Figure 3 12 Installing the Serverboard in the Serverboard Node Drawer...
Страница 46: ...or each node Installing the Riser Card onto the Riser Card Bracket 1 Disconnect the power supply and lay the chassis on a flat surface 2 Pull the serverboard node drawer from the chassis 3 Remove the...
Страница 47: ...il the failed unit has been replaced Replacement units can be ordered directly from Supermicro see contact information in the Preface Removing Replacing the Power Supply 1 Begin by removing power from...
Страница 48: ...Supermico optional A TPM Port 80 connector is a security device that supports encryption and authentication in hard drives It allows the motherboard to deny access if the TPM associated with the hard...
Страница 49: ...Ground I SATA 3 0 Ports The X11DPT L has eight I SATA 3 0 ports I SATA0 7 on the motherboard These SATA ports are supported by the Intel C621 chipset I SATA0 5 are supported by SXB1 I SATA6 I SATA7 ca...
Страница 50: ...t GbE LAN connections on the motherboard In addition an IPMI dedicated LAN that supports GbE LAN is located next to USB 0 1 ports on the back panel All Ethernet ports accept RJ45 type cables Please re...
Страница 51: ...o the IPMI User s Guide posted on our website at http www supermicro com UID Switch Pin Definitions Pin Definition 1 Ground 2 Ground 3 Button In 4 Button In UID LED Pin Definitions Color Status Blue O...
Страница 52: ...Connector Pins Jumper Setting 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally cleari...
Страница 53: ...fault setting is Reset Note When Watch Dog is enabled the user needs to write their own application software to disable it Watch Dog Jumper Settings Jumper Setting Definition Pins 1 2 Reset Pins 2 3 N...
Страница 54: ...Definition Off No Connection 10 Mbps or 100 Mbps Green 100 Mbps Orange 1 Gbps IPMI LAN Activity LED Link LED LAN 1 LAN 2 IPMI LAN X8ST3 F LAN1 LAN2 Activity LED Right LED Color Status Definition Amber...
Страница 55: ...ble below for the LED status BMC Heartbeat LED Indicator LED Color Definition Green Blinking BMC Normal UID LED LED Indicator LED Color Definition Blue On Unit Identified Unit ID LED A rear UID LED in...
Страница 56: ...at www supermicro com support manuals Installing the OS 1 Create a method to access the MS Windows installation ISO file That might be a DVD perhaps using an external USB SATA DVD drive or a USB flas...
Страница 57: ...iver browse the USB flash drive for the proper driver files For RAID choose the SATA sSATA RAID driver indicated then choose the storage drive on which you want to install it For non RAID choose the S...
Страница 58: ...referred Another option is to go to the Supermicro website at http www supermicro com products Find the product page for your motherboard and Download the Latest Drivers and Utilities Insert the flash...
Страница 59: ...Protocol SNMP SuperDoctor 5 comes in local and remote management versions and can be used with Nagios to maximize your system monitoring needs With SuperDoctor 5 Management Server SSM Server you can r...
Страница 60: ...ent Platform Management Interface IPMI IPMI is used to provide remote access monitoring and management There are several BIOS settings that are related to IPMI For general documentation and informatio...
Страница 61: ...h main BIOS menu option is described in this manual The Main BIOS screen has two main frames The left frame displays all the options that can be configured Grayed out options cannot be configured The...
Страница 62: ...date and time Highlight System Date or System Time using the arrow keys Enter new values using the keyboard Press the Tab key or the arrow keys to move between fields The date must be entered in MM D...
Страница 63: ...63 CPLD Version This item displays the version of the CPLD Complex Programmable Logical Device used in the system Memory Information Total Memory This item displays the total size of memory available...
Страница 64: ...Use this feature to select the screen display between the POST messages and the OEM logo upon bootup Select Disabled to display the POST messages Select Enabled to display the OEM logo instead of the...
Страница 65: ...oot Install Windows 7 USB Support Enable this feature to use the USB keyboard and mouse during the Windows 7 installation since the native XHCI driver support is unavailable Use a SATA optical drive a...
Страница 66: ...Instant Off and 4 Seconds Override CPU Configuration Processor Configuration The following CPU information will be displayed Processor BSP Revision Processor Socket Processor ID Processor Frequency P...
Страница 67: ...s the system to run several operating systems simultaneously The options are Disable and Enable PPIN Control Select Unlock Enable to use the Protected Processor Inventory Number PPIN in the system The...
Страница 68: ...able Chipset Configuration Warning Setting the wrong values in the following features may cause the system to malfunction North Bridge This feature allows users to configure the following North Bridge...
Страница 69: ...to be sent to the memory controller requesting the prefetch in parallel to an LLC Last Level Cache look up The options are Disable and Enable KTI Prefetch KTI Prefetch is a feature that enables memor...
Страница 70: ...memory modules The options are Auto 1866 2000 2133 2400 2666 and 2933 Note 2933 MHz memory is supported by 2nd Gen Intel Xeon Scalable SP 82xx 62xx series processors only Data Scrambling for NVDIMM U...
Страница 71: ...mory to be mirrored between two channels providing 100 re dundancy The options are Disable Mirror Mode 1LM and Mirror Mode 2LM UEFI ARM Mirror This options allows the system to imitate the behavior of...
Страница 72: ...ite back one cache line every 16K cycles if there is no delay caused by internal processing By using this method roughly 64 GB of memory behind the IO hub will be scrubbed every day The options are Di...
Страница 73: ...ize of 128 or 256 Options are 128B 256B and Auto Auto is enabled by default RSC T2R 884 SLOT2 Available when the device is detected by the system Link Speed Use this item to select the link speed for...
Страница 74: ...ility security and availability in networking and data sharing The options are Enabled and Disabled ACS Control This feature allows users to choose whether they want to enable or disable PCIe Access C...
Страница 75: ...the Intel Volume Management Device Technology for this spe cific root port The options are Disable and Enable CPU1 SLOT4 PCI E 3 0 X8 VMD Available when the device is detected by the system Select En...
Страница 76: ...Technology for this spe cific root port The options are Disable and Enable Hot Plug Capable Available when the device is detected by the system Use this feature to enable hot plug support for PCIe ro...
Страница 77: ...Controller Interface hand off The XHCI ownership changes should be claimed by the XHCI driver The options are Enabled and Disabled Port 60 64 Emulation Select Enabled for legacy I O support for USB de...
Страница 78: ...tions are AHCI and RAID SATA HDD Unlock This feature allows the user to remove any password protected SATA disk drives The options are Disable and Enable Aggressive Link Power Management When this ite...
Страница 79: ...rted by the Intel PCH chip and displays the following items sSATA Controller This item enables or disables the onboard sSATA controller supported by the Intel PCH chip The options are Enable and Disab...
Страница 80: ...o enhance system performance The options are Auto 128 Bytes 256 Bytes 512 Bytes 1024 Bytes 2048 Bytes and 4096 Bytes MMCFG Base Use this item to select the low base address for PCIE adapters to increa...
Страница 81: ...e settings if Enabled is selected the policy will be enabled all the time The options are Enabled and Disabled Onboard LAN Device Select Enabled to enable the Onbaord LAN device The options are Disabl...
Страница 82: ...hange the value The default setting is 1 Super IO Configuration The following Super IO information will be displayed Super IO Chip AST2500 Serial Port 1 Configuration This submenu allows the user the...
Страница 83: ...Port 2 as a Serial Over LAN SOL port for console The options are SOL and COM Serial Port Console Redirection COM1 Console Redirection Select Enabled to enable console redirection support for a serial...
Страница 84: ...sent with your data bits The options are None Even Odd Mark and Space Stop Bits A stop bit indicates the end of a serial data packet Select 1 Stop Bit for standard serial data communication Select 2 S...
Страница 85: ...change data with the client computer which is the remote computer used by the user If the item above is set to Enabled the following items will become available for configuration Terminal Type Use thi...
Страница 86: ...start sending data when the receiving buffer is empty The options are None and Hardware RTS CTS VT UTF8 Combo Key Support Select Enabled to enable VT UTF8 Combination Key support for ANSI VT100 termi...
Страница 87: ...available for configuration Console Redirection Settings Out of Band Mgmt Port The feature selects a serial port in a client server to be used by the Microsoft Windows Emergency Management Services E...
Страница 88: ...r the system to handle hardware errors within the Windows OS environment to reduce system crashes and to enhance system recovery and health monitoring The options are Disabled and Enabled High Precisi...
Страница 89: ...keys During system boot the platform firmware uses this trusted public key to verify a digital signature in an attempt to manage and control the security of the platform firmware used in a host system...
Страница 90: ...ease refer to the TPM manual at http www supermicro com manuals other Intel R Virtual RAID on CPU When this submenu is selected and the RAID devices are detected the BIOS screen displays the following...
Страница 91: ...This item displays the information status of driver installed in the system Blink LEDs Use this feature to identify the physical network port by blinking the associated LED Use the keybaord to select...
Страница 92: ...ed in the event log will not be erased Select Yes Next Reset data in the event log will be erased upon next system reboot Select Yes Every Reset data in the event log will be erased upon every system...
Страница 93: ...s that a duplicate event must happen before the MECI counter is incremented This is a numeric value The default value is 1 METW The Multiple Event Time Window METW defines number of minutes must pass...
Страница 94: ...e IPMI firmware installed in your system System Event Log Enabling Disabling Options SEL Components Select Enabled for all system event logging at bootup The options are Disabled and Enabled Erasing S...
Страница 95: ...ted LAN Configuration Address Source Available when Update IPMI LAN Configuration is set to Yes This feature allows the user to select the source of the IP address for this computer If Static is selec...
Страница 96: ...o enable IPV6 support The options are Enabled and Disabled Configuration Address Source This feature allows the user to select the source of the IP address for this computer If Static is selected you...
Страница 97: ...a new or change an existing user password Administrator Password Password Check Select Setup for the system to check for a password at Setup Select Always for the system to check for a password at bo...
Страница 98: ...tem boot The options are Disabled and Enabled Key Management This submenu allows the user to configure the following Key Management settings Provision Factory Default Keys Select Enabled to install th...
Страница 99: ...user to configure the settings of the Forbidden Signatures The options are Set New and Append Authorized TimeStamps This feature allows the user to configure the settings of the authorized TimeStamps...
Страница 100: ...tem to boot to EFI OS if boot fails from Legacy boot order The options are Disabled and Enabled Fixed Boot Order Priorities This option prioritizes the order of bootable devices that the system to boo...
Страница 101: ...o specify which UEFI devices are boot devices Boot Option 1 The options are UEFI Built in EFI Shell and Disabled Hard Disk Drive BBS Priorities UEFI Boot Option 1 The options are ISATA P0 HGST HUH7280...
Страница 102: ...SATA Port 5 and Disabled UEFI Boot Option 5 The options are ISATA P0 HGST HUH728080ALE600 SATA Port 0 ISATA P1 HGST HUH728080ALE600 SATA Port 1 ISATA P2 HGST HUH728080ALE600 SATA Port 2 ISATA P3 HGST...
Страница 103: ...s Enter Save Changes and Reset After completing the system configuration changes select this option to save the changes you have made This will not reset reboot the system Save Changes When you have c...
Страница 104: ...IOS setup for future use Restore User Defaults To set this feature select Restore User Defaults from the Save Exit menu and press Enter Use this feature to retrieve user defined settings that were sav...
Страница 105: ...for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis The...
Страница 106: ...po considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontra...
Страница 107: ...en dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan h...
Страница 108: ...mentaci n Attention Avant de brancher le syst me sur la source d alimentation consulter les directives d installation Circuit Breaker Waarschuwing Raadpleeg de installatie instructies voordat u het sy...
Страница 109: ...es del edificio Aseg rese de que el dispositivo de protecci n no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit d pend de l insta...
Страница 110: ...e energ a y del cable el ctrico quitado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me do...
Страница 111: ...bels aangesloten op de voeding en van de behuizing te verwijderen Equipment Installation Warning Only trained and qualified personnel should be allowed to install replace or service this equipment War...
Страница 112: ...tention Il est vivement recommand de confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s Warning This unit is intended for installation...
Страница 113: ...a una de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r serv s L acc s...
Страница 114: ...emblable ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incor...
Страница 115: ...aanbevolen wordt Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd te worden Redundant Power Supplies Warning This unit might have more than one power supply connection All co...
Страница 116: ...omloos te maken Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Atte...
Страница 117: ...vertencia Cuando el sistema est en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques ci...
Страница 118: ...cumplir con las normas de electricidad locales y nacionales Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is...
Страница 119: ...le elektriciteitsvoorschriften Warnung Die Entsorgung dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Warning Ultimate disposal of this product should be handled accordi...
Страница 120: ...recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Warning Hazardous moving...
Страница 121: ...stornilladores y todos los objetos lejos de las aberturas del ventilador Attention Pieces mobiles dangereuses Se tenir a l ecart des lames du ventilateur Il est possible que les ventilateurs soient to...
Страница 122: ...UL oder CAS zertifizierten Kabeln mit UL CSA gekennzeichnet an Ger ten oder Produkten die nicht mit Supermicro gekennzeichnet sind AC AC UL CSA UL CSE Supermicro Supermicro UL CSA UL CSA Supermicro U...
Страница 123: ...le code pour tous les autres appareils lectriques sauf les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA Supermicro UL CSA UL CSA Supermicro Advertencia Cuando instale el producto ut...
Страница 124: ...Aansluitmethode deze moet altijd voldoen aan de lokale voorschriften en veiligheidsnormen inclusief de juiste kabeldikte en stekker Het gebruik van niet geschikte Kabels en of Adapters kan een storin...
Страница 125: ...de On chip Intel C621 controller Drive Bays Per Node 6 Hot swap 3 5 SATA3 drive bays PCI Expansion Slots Per Node 2 PCI E 3 0 x8 FH HL or 1 PCI E 3 0 x8 FH HL 1 PCI E 3 0 x4 FH HL 1 PCI E 3 0 x 4 LP 8...
Страница 126: ...IEC UL 60950 1 Compliant UL or CSA Listed USA and Canada CE Marking Europe Other VCCI CISPR 32 and AS NZS CISPR 32 Environmental Directive 2011 65 EU and Delegated Directive EU 2015 863 and Directive...
Страница 127: ...how to enable the features of secure boot The F 4 section states Key Management settings C 1 Boot mode select Feature Press Del key continuously during system boot to enter the BIOS Setup utility Nav...
Страница 128: ...Custom Select Standard to load manufacturer s default secure variables Selecting Custom allows users to change the image execution policy and to manage secure boot keys CSM Support Select Enabled to s...
Страница 129: ...Boot Settings Follow the steps below to enable Secure Boot Step 1 Set Secure Boot Mode to Standard Press Yes to install factory default keys as needed Note The Key Management menu will become unavail...
Страница 130: ...changes to take effect press F4 to save the settings and exit the BIOS Setup utility Step 3 Press Del key continuously during system boot to enter the BIOS Setup utility Navigate to the Security tab a...
Страница 131: ...has not been set to Disabled after the completion of Step 4 please be sure to set it to Disabled Step 4 For the changes to take effect press F4 to save the settings and exit the BIOS Setup utility Th...
Страница 132: ...the default secure boot keys set by the manufacturer when system is in the setup mode The options are Disabled and Enabled Reset to Setup Mode Select Yes to clear all secure boot variables and reset...
Страница 133: ...ich is pre installed in firmware during manufacturing provides full control of the secure boot key hierarchy The options are Save to File Set New and Erase Select Save to File to save the current PKs...
Страница 134: ...SuperServer 6029TR DTR User s Manual 134 Press Enter and the following screen will appear To load the manufacturer s defaults navigate to Yes and press Enter The following screen will appear...
Страница 135: ...Appendix C Secure Boot Settings 135 To load it from the external media navigate to No and press Enter When the following screen appears select the USB flash drive that contains the desired file...
Страница 136: ...SuperServer 6029TR DTR User s Manual 136 Erase Use the arrow keys to select Erase and press Enter to clear the current PKs and the system will enter the secure boot setup mode...
Страница 137: ...e used by secure boot to protect access to sig natures databases The options are Save to File Set New Append and Erase Select Save to File to save the current KEKs to a FAT formatted USB flash drive S...
Страница 138: ...SuperServer 6029TR DTR User s Manual 138 Press Enter and the following screen will appear To load the manufacturer s defaults navigate to Yes and press Enter The following screen will appear...
Страница 139: ...Appendix C Secure Boot Settings 139 To load it from the external media navigate to No and press Enter When the following screen appears select the USB flash drive that contains the desired file...
Страница 140: ...from the external media Select Append to add variables to the existing DB Select Erase to clear the current DB Forbidden Signatures Forbidden Signature Database DBX which is the inverse of DB contains...
Страница 141: ...e stamp certificates The options are Save to File Set New Append and Erase Select Save to File to save the current DBT to a FAT formatted USB flash drive Select Set New to load the manufacturer s defa...
Страница 142: ...recovery vari ables The options are Save to File Set New Append and Erase Select Save to File to save the current DBR to a FAT formatted USB flash drive Select Set New to load the manufacturer s defa...
Страница 143: ...oard Intel LAN devices via the BIOS Setup utility supported by the Unified Extensible Firmware Interface UEFI driver D 1 Network Interface Card NIC Settings Press Del key continuously during system bo...
Страница 144: ...LAN device s will become available for configuration as shown below Note If Onboard LAN1 Option ROM is set to EFI all items for onboard LAN option ROM will be set to EFI by the EFI driver Additionall...
Страница 145: ...Interface Card NIC Settings 145 Use the arrow keys to select the desired onboard LAN device as shown below Press Enter and the following screen will appear It displays the detailed information for th...
Страница 146: ...ver 6029TR DTR User s Manual 146 Blink LEDs This item allows the user to set the LED blink duration in seconds The valid range is 0 15 seconds NIC Configuration Use the arrow keys to select NIC Config...
Страница 147: ...147 Press Enter and the following screen will appear Wake on LAN Use the arrow keys to select Wake On LAN and press Enter The following screen will appear The options are Disabled and Enabled Set this...