background image

®

S

UPER

S

ERVER

 6022P-8R

S

UPER

S

ERVER

 6022P-8

USER’S MANUAL

1.0a

   

S

UPER

Содержание SUPERSERVER 6022P-8R

Страница 1: ...SUPERSERVER 6022P 8R SUPERSERVER 6022P 8 USER SMANUAL 1 0a SUPER...

Страница 2: ...R INABILITY TO USE THIS PRODUCT OR DOCUMENTATION EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES IN PARTICULAR THE VENDOR SHALL NOT HAVE LIABILITY FOR ANY HARDWARE SOFTWARE OR DATA STORED OR USED W...

Страница 3: ...updates on supported processors Manual Organization Chapter 1 Introduction The first chapter provides a checklist of the main components included with the server system and describes the main feature...

Страница 4: ...er to this chapter when adding or removing processors or main memory and when reconfiguring the motherboard Chapter 6 Advanced Chassis Setup Refer to Chapter 6 for detailed information on the 2U SC822...

Страница 5: ...v Preface Notes...

Страница 6: ...r Setup 2 1 Choosing a Setup Location 2 2 Rack Precautions 2 2 Server Precautions 2 2 2 4 Installing the 6022P 8R 6022P 8 into a Rack 2 3 Identifying the Sections of the Rack Rails 2 3 Installing the...

Страница 7: ...ing Power Cables 5 5 Connecting the Control Panel 5 6 5 4 I O Ports 5 7 5 5 Installing Memory 5 7 5 6 Adding PCI Cards 5 9 5 7 Motherboard Layout 5 10 P4DP8 G2 Quick Reference 5 11 5 8 Connector Defin...

Страница 8: ...oppy Hard Drive and SCSI Connections 5 22 Floppy Connector 5 22 IDE Connectors 5 23 Ultra320 SCSI Connectors 5 23 5 12 Installing Software Dirvers 5 24 Chapter 6 Advanced Chassis Setup 6 1 Static Sens...

Страница 9: ...r 7 BIOS 7 1 Introduction 7 1 7 2 Running Setup 7 2 7 3 Main 7 2 7 4 Advanced 7 6 7 5 Security 7 15 7 6 Power 7 17 7 7 Boot 7 19 7 8 PIR 7 20 7 9 Exit 7 22 Appendices Appendix A BIOS POST Messages A 1...

Страница 10: ...SUPERSERVER 6022P 8R 6022P 8 User s Manual x Notes...

Страница 11: ...for use with the SuperServer 6022P 8R 6022P 8 www supermicro com In addition to the mainboard and chassis various hardware components may have been included with your SuperServer 6022P 8R 6022P 8 as...

Страница 12: ...Attach ment The SCSI drives are connected to an SCA backplane that provides power bus termination and configuration settings The SCSI drives are also hot swap units Control Panel The SC822S control p...

Страница 13: ...22S chassis revolutionary cooling design that includes four 8 cm redundant system cooling intake fans The fans plug into chassis fan connectors that are located behind the drive bays They operate cont...

Страница 14: ...interface is a 266 MB sec point to point connection using an 8 bit wide 66 MHz base clock at a 4x data transfer rate The P64H2 interface is a 1 GB s point to point connection using a 16 bit wide 66 M...

Страница 15: ...the speeds of these slots if needed see Chapter 5 ATI Graphics Controller The P4DP8 G2 features an integrated ATI video controller based on the Rage XL graphics chip Rage XL utilizes 8 MB of memory a...

Страница 16: ...Address SuperMicro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl...

Страница 17: ...and note if it was damaged in any way If the server itself shows damage you should file a damage claim with the carrier who deliv ered it Decide on a suitable location for the rack unit that will hol...

Страница 18: ...re extending a component from the rack You should extend only one component at a time extending two or more simultaneously may cause the rack to become unstable Server Precautions Review the electrica...

Страница 19: ...e Rack Rails You should have received two rack rail assemblies with the SuperServer 6022P 8R 6022P 8 Each of these assemblies consist of three sections an inner fixed chassis rail that secures to the...

Страница 20: ...rack Locking Tabs As you have seen both chassis rails have a locking tab which serves two functions The first is to lock the server into place when installed and pushed fully into the rack which is i...

Страница 21: ...e front of the rack rails Slide the chassis rails into the rack rails keeping the pressure even on both sides you may have to depress the locking tabs when inserting See Figure 2 3 When the server has...

Страница 22: ...ou are installing the SuperServer 6022P 8R 6022P 8 into a Telco type rack follow the directions given on the previous pages for rack installation The only difference in the installation procedure will...

Страница 23: ...the top cover from the chassis to gain full access to the inside of the server 2 Check the CPUs processors You should have one or two processors already installed into the system board Each processor...

Страница 24: ...the SCSI drives and SCA backplane have been properly installed and all connections have been made 1 Accessing the drive bays All drives are accessable from the front of the server For servicing the C...

Страница 25: ...airflow Airflow is provided by two heavy duty 10 cm blower fans The system component layout was carefully designed to direct sufficient cooling air flow to the components that generate the most heat...

Страница 26: ...2 10 SUPERSERVER 6022P 8R 6022P 8 Manual Notes...

Страница 27: ...ttons on the chassis control panel 3 2 Control Panel Buttons There are two push button buttons located on the front of the chassis These are in order from left to right a reset button and a power on o...

Страница 28: ...This may be caused by cables obstructing the airflow in the system or the ambient room tem perature being too warm You should also check to make sure that the chassis cover is installed and that all f...

Страница 29: ...has two LEDs l Green When illuminated the green LED on the front of the SCSI drive carrier indicates drive activity A connection to the SCSI SCA backplane enables this LED to blink on and off when th...

Страница 30: ...SUPERSERVER 6022P 8R 6022P 8 User s Manual 3 4 Notes...

Страница 31: ...ard memory modules and the CD ROM and floppy drives When disconnecting power you should first power down the system with the operating system and then unplug the power cords of all the power supply un...

Страница 32: ...circuits or be pulled into a cooling fan l Remove any jewelry or metal objects from your body which are excellent metal conductors that can create short circuits and harm you if they come into contact...

Страница 33: ...Touch a grounded metal object before removing the board from the antistatic bag l Do not let components or PCBs come into contact with your clothing which may retain a charge even if you are wearing...

Страница 34: ...ing Precautions Care must be taken to assure that the chassis cover is in place when the 6022P 8R 6022P 8 is operating to assure proper cooling Out of warranty damage to the 6022P 8R 6022P 8 system ca...

Страница 35: ...that the size and weight of the mother board can cause it to bend if handled improperly which may result in dam age To prevent the motherboard from bending keep one hand under the center of the board...

Страница 36: ...do not place the motherboard on a conductive surface which can damage the BIOS battery and prevent the system from booting up 1 Lift the lever on the CPU socket Lift the lever completely or you will...

Страница 37: ...lips into their proper position When correctly installed the retention clips should click into place and the three black tabs on the CPU retention pieces should protrude fully through the correspondin...

Страница 38: ...5 4 SUPERSERVER 6022P 8R 6022P 8 User s Manual Figure 5 2 Heatsink Installation...

Страница 39: ...nnect to the pin 1 locations If you are configuring the sys tem keep the airflow in mind when routing the cables The following data cables with their motherboard connector locations noted should be co...

Страница 40: ...nectors See Figure 5 3 for the pin locations of the various front control panel buttons and LED indicators Please note that even and odd numbered pins are on opposite sides of each header All JF2 wire...

Страница 41: ...e Also note that the memory is interleaved to improve performance see step 1 DIMM Installation See Figure 5 5 1 Insert the desired number of DIMMs into the memory slots starting with Bank 1 DIMM 1A DI...

Страница 42: ...ntion to the bottom notch To Remove Use your thumbs to gently push each release tab outward to free the DIMM from the slot Memory Support The P4DP8 G2 only supports ECC registered PC1600 DDR 200 memor...

Страница 43: ...fore installing a PCI add on card make sure you install it into a slot that supports the speed of the card see step 1 above Begin by swinging the release tab on the I O backpanel shield out to the lef...

Страница 44: ...an JP9 JP33 USB 4 CPU2 Chassis Fan CPU2 Fan JL1 J3A J2A JP7 IDE 1 IDE 2 FLOPPY Ultra III LVD SCSI CH A Chassis Fan2 SMB IPMB BIOS Battery P64H2 P64H2 MCH AIC 7902W ICH3 IPMI USB 2 USB 3 Speaker JP32 1...

Страница 45: ...DIMM 4B Memory RAM Slots COM1 COM2 COM1 COM2 Serial Port Connector CPU CHS OH FAN CPU Chassis Overheat Fan Headers J7 Parallel Printer Port J9 PS 2 Keyboard Mouse Ports J13 J14 USB2 3 Headers J15 Sec...

Страница 46: ...cation Make sure that the orientation of the connector is correct See the table on the right for pin definitions Pins 1 thru 4 5 thru 8 Definition Ground 12v 8 Pin 12v Po w er Supply Connector J15 PWR...

Страница 47: ...ch the NIC1 LED cable to display net work activity Refer to the table on the right for pin definitions NIC1 LED Pin Definitions JF2 Pin Number 11 12 Definition Vcc GND O verheat O H LED Pin Definition...

Страница 48: ...To turn off the power when set to suspend mode de press the button for at least 4 seconds Refer to the table on the right for pin definitions Pin Number 1 2 Definition PW _O N Ground Pow er Button Con...

Страница 49: ...an Headers The motherboard has three fan headers These are designated CPU 1 Chassis Fan CPU 2 Chas sis Fan and Chassis Fan 3 See the table on the right for pin defini tions Serial Ports The COM1 seria...

Страница 50: ...h a Wake on LAN connector and cable Wake On Ring The Wake On Ring header is des ignated WOR This function al lows your computer to receive and wake up by an incoming call to the modem when in sustpend...

Страница 51: ...CMOS CMO S C lear Jum per Settings JBT 1 Jumper Position 1 2 2 3 Definition Normal CMOS Clear Position 1 2 Position 2 3 Normal CMOS Clear 5 9 Jumper Settings Explanation of Jumpers To modify the oper...

Страница 52: ...tended for use with Supermicro chassis See the table on the right for jumper settings Jumper Position Open Closed Definition CPU CPU Chassis CPU Chassis CPU Fan Select Jum per Settings JP33 GLAN Enabl...

Страница 53: ...JPA2 Watchdog Enable Disable The WD jumper located on JD1 al lows you to enableor disable the Watchdog feature The default po sition is open to disable the Watch dog timer When enabled Watch dog can...

Страница 54: ...6 Refer to the table on the right to set the speed of slot 6 with jumpers JP14 JP15 and JP13 Default setting PCI X Bus SpeedJum per Settings for Slot 5 JP10 JP11 JP12 Protocol Max Freq Off Off Off PCI...

Страница 55: ...operate as 66 MHz max PCI cards You may run a single 66 MHz PCI X card in slots 1 4 only if the other three slots remain empty 5 10 Onboard Indicators GLAN LEDs The Ethernet ports located beside the V...

Страница 56: ...d wires always connects to drive A and the connector that does not have twisted wires always connects to drive B Pin Number Function 1 GND 3 GND 5 Key 7 GND 9 GND 11 GND 13 GND 15 GND 17 GND 19 GND 21...

Страница 57: ...68 68 pin U ltra320 SCSI Connectors JA1 JA2 JA4 Ultra320 SCSI Connectors Refer to the table on the right for the pin defi nitions of the Ultra320 SCSI connectors lo cated at JA1 and JA2 IDE Connector...

Страница 58: ...inserting this CD into your CD ROM drive the display shown in Figure 5 8 should appear If this display does not appear double click on the My Computer icon and then on the icon representing your CD RO...

Страница 59: ...ully The following measures are generally sufficient to protect your equipment from ESD damage Precautions l Use a grounded wrist strap designed to prevent static discharge l Touch a grounded metal ob...

Страница 60: ...n Connect the cable from JF2 on the motherboard to JP4 on the Control Panel PCB printed circuit board Make sure the red wire plugs into pin 1 on both JF2 and JP4 Pull all excess cabling out of the air...

Страница 61: ...to function upon connection to its fan header on the P4DP8 G2 motherboard Replacing System Cooling Fans 1 Removing a fan Remove the chassis cover Press the tabs on the top of the fan housing and remo...

Страница 62: ...erver 6022P 8R 6022P 8 CD ROM Floppy Disk Drive For installing removing the CD ROM or floppy disk drive you will need to gain access to the inside of the server by removing the top cover of the chassi...

Страница 63: ...SCSI drive install a drive into the carrier with the printed circuit board side toward the carrier so that the mounting holes align with those in the carrier Secure the drive to the carrier with four...

Страница 64: ...The SCSI drives are hot swap units meaning that they can be installed and removed while the system is running To remove a SCSI drive first push the colored release button located beside the drive s L...

Страница 65: ...in the 5 1 4 Drive Bay 1 Mounting the component in the drive carrier A component such as an IDE hard drive or an additional SCSI drive that can fit into a standard IDE drive bay can be mounted in the...

Страница 66: ...in their bays The floppy disk drive cable has seven twisted wires A color mark on a cable typically designates the location of pin 1 A single floppy disk drive ribbon cable has 34 wires and two conne...

Страница 67: ...bility meaning you can replace the failed unit without powering down the system Removing Replacing the Power Supply You do not need to shut down the system to replace a power supply unit The redundant...

Страница 68: ...n the power switch on the control panel off then unplug the power cord from the system Remove the chassis cover by pressing the two release buttons on the top of the chassis near the front and push th...

Страница 69: ...tle electrical power When the computer is turned off a back up battery provides power to the BIOS flash chip enabling it to retain system parameters Each time the computer is powered on the computer i...

Страница 70: ...pressing Delete immediately after turning the system on or 2 When the message shown below appears briefly at the bottom of the screen during the POST Power On Self Test press the Delete key to activat...

Страница 71: ...orrect data Press the Enter key to save the data Phoenix BIOS Setup Utility Main Advanced Security Power Boot Exit System Time 16 19 20 System Date 02 02 02 Legacy Diskette A 1 44 1 25 MB Legacy Diske...

Страница 72: ...Master Slave and IDE Secondary Master Slave slots Hit Enter to activate the following sub menu screen for detailed options of these items Set the correct configurations accordingly The items included...

Страница 73: ...ll access the IDE Primary Master Device via LBA mode The options are Enabled and Disabled 32 bit I O Selects 32 bit I O operation Options are Enabled and Disabled Transfer Mode Selects the transfer mo...

Страница 74: ...f enabled this feature will speed up the POST Power On Self Test routine after the computer is turned on The settings are Enabled and Disabled If Disabled the POST routine will run at normal speed Qui...

Страница 75: ...gacy USB Support This setting allows you to enable support for Legacy USB devices The settings are Enabled and Disabled Installed OS This setting allows you to choose which operating system you are us...

Страница 76: ...z 66 MHz 100 MHz and 133 MHz PCI PCIX Frequency Slot 6 Use this setting to change the speed of PCI PCIX slot 6 Options are Auto 33 MHz 66 MHz 100 MHz and 133 MHz uPCI Device Slot 1 Slot 6 Access the s...

Страница 77: ...r various sections of cache memory Uncache Write Protect Write Back Write Through or Disable See the Item Specific Help window for details uI O Device Configuration Access the submenu to make changes...

Страница 78: ...This setting allows you to assign control of serial port B The options are Enabled user defined Disabled and Auto BIOS controlled Mode Specify the type of device that will be connected to serial port...

Страница 79: ...l Options are DMA1 and DMA3 Floppy Disk Controller This setting allows you to assign control of the floppy disk controller The options are Enabled user defined Disabled and Auto BIOS controlled Base I...

Страница 80: ...required to qualify as an ECC error Options are None Single Bit Multiple Bit and Both uAdvanced Processor Options Access the submenu to make changes to the following settings CPU Speed This is a displ...

Страница 81: ...make changes to the following settings Event Log Validity This is a display not a setting informing you of the event log validity Event Log Capacity This is a display not a setting informing you of t...

Страница 82: ...e redirection Console Type Choose from the available options to select the console type for console redirection Flow Control Choose from the available options to select the flow control for console re...

Страница 83: ...has not been used and Set means a supervisor password has been entered for the system User Password Is This displays whether a user password has been entered for the system Clear means such a passwor...

Страница 84: ...Enter key When prompted type the user s password in the dialogue box to set or to change the user s password which allows access to the system at boot up Password on Boot This setting allows you to r...

Страница 85: ...tion and Power Interface power management on your system Options are Yes and No Power Savings This setting sets the degree of power saving for the system The options are Disabled Customized Maximum Po...

Страница 86: ...u want the system to wake up the above setting must be set to On Enter the time with the number keys Resume on Modem Ring Use this setting to enable or disable the WOR Wake on Ring feature Options are...

Страница 87: ...nd the field See details on how to change the order and specs of devices in the Item Specific Help window CD ROM Drive See details on how to change the order and specs of the CD ROM drive in the Item...

Страница 88: ...the arrow keys and pressing Enter All PIR BIOS Setup options are described in this section Select the Processor s PIR Selects the processor PIR Options are A0h A1h A2h A3h A4h A5h A6h A7h A8h A8h AAh...

Страница 89: ...ure Data Other Data OEM Data uHardware Monitor Logic Highlight this and hit Enter to see monitor data for the following items CPU1 Temperature CPU2 Temperature System Temperature CPU Fan1 CPU1 Chassis...

Страница 90: ...he arrow keys You should see the following display All Exit BIOS settings are described in this section Phoenix BIOS Setup Utility Main Advanced Security Power Boot PIR Exit Exit Saving Changes Exit D...

Страница 91: ...out saving any changes you may have made Load Setup Defaults Highlight this item and hit Enter to load the default settings for all items in the BIOS Setup These are the safest settings to use Discard...

Страница 92: ...7 24 SUPERSERVER 6022P 8R 6022P 8 Manual Notes...

Страница 93: ...ed Keyboard controller failed test May require replacing keyboard controller Keyboard locked Unlock key switch Unlock the system to proceed Monitor type does not match CMOS Run SETUP Monitor type not...

Страница 94: ...ious POST did not complete successfully POST loads default values and offers to run Setup If the failure was caused by incorrect values and they are not corrected the next boot will likely fail On sys...

Страница 95: ...tware NMI Failed ServerBIOS2 test error Cannot generate software NMI Non Maskable Interrupt Fail Safe Timer NMI Failed ServerBIOS2 test error Fail Safe Timer takes too long device Address Conflict Add...

Страница 96: ...ssfully tested nnnn kB System RAM Passed Where nnnn is the amount of system RAM in kilobytes successfully tested One or more I2O Block Storage Devices were excluded from the Setup Boot Menu There was...

Страница 97: ...Write down and follow the information shown on the screen Press F2 to enter Setup Optional message displayed during POST Can be turned off in Setup PS 2 Mouse PS 2 mouse identified Run the I2O Configu...

Страница 98: ...A 6 SUPERSERVER 6022P 8R 6022P 8 Manual Notes...

Страница 99: ...the error to port 80h attempt to initialize video and write the error in the top left corner of the screen The following is a list of codes that may be written to port 80h Appendix B BIOS POST Codes P...

Страница 100: ...adow 32h Test CPU bus clock frequency 33h Initialize Phoenix Dispatch Manager 36h Warm start shut down 38h Shadow system BIOS ROM 3Ah Auto size cache 3Ch Advanced configuration of chipset registers 3D...

Страница 101: ...are interrupt vectors 7Dh Initialize Intelligent System Monitoring 7Eh Initialize coprocessor if present 80h Disable onboard Super I O ports and IRQs 81h Late POST device initialization 82h Detect and...

Страница 102: ...orm RomPilot about the end of POST B2h POST done prepare to boot operating system B4h 1 One short beep before boot B5h Terminate QuietBoot optional B6h Check password optional B7h Initialize ACPI BIOS...

Страница 103: ...tialize PIC and DMA ECh Initialize Memory type EDh Initialize Memory size EEh Shadow Boot Block EFh System memory test F0h Initialize interrupt vectors F1h Initialize Run Time Clock F2h Initialize vid...

Страница 104: ...B 6 SUPERSERVER 6022P 8R 6022P 8R Manual Notes...

Страница 105: ...ty Eight 184 pin DDR DIMM sockets supporting up to 16 GB of registered ECC PC1600 DDR 200 SDRAM Note Interleaved memory requires memory to be installed two at a time PC2100 memory modules are supporte...

Страница 106: ...cy 47hz 63hz Maximum Output 5V and 3 3V 45A total 5V 3 3V and 12V 385W total System Cooling Four 8 cm ball bearing fans Operating Environment Operating Temperature Range 0 to 35 degrees C Humidity Ran...