Chapter 2: Server Installation
2-7
2-5
Checking the Motherboard Setup
After you install the 6021F in the rack, you will need to open the unit to
make sure the motherboard is properly installed and all the connections
have been made.
1. Accessing the inside of the 6021F (see Figure 2-5):
First, release the retention screws that secure the unit to the rack.
Grasp the two handles on either side and pull the unit straight out until it
locks (you will hear a "click"). Next, depress the two buttons on the top
of the chassis to release the top cover. There is a large rectangular
recess in the middle front of the top cover to help you push the cover
away from you until it stops. You can then lift the top cover from the
chassis to gain full access to the inside of the server.
2. Check the CPUs (processors):
You should have one or two processors already installed into the
system board. Each processor should have its own heatsink attached.
See Section 5-5 for instructions on processor installation.
3. Verify the proper CPU core/bus ratio setting:
You need to verify that the CPU core/bus ratio as set with DIP Switch 1
matches the speed of your installed processors. This DIP Switch is
defaulted to 5.5, which corresponds to 550 MHz processors running on
a 100 MHz front side bus (FSB). If the setting is different or if you are
using processors of a different speed, you may need to change this
setting. (See Section 5-9 for setting the core/bus ratio with DIP Switch
1.) This speed can also be set in BIOS.
4. Check the system memory:
Your 6021F server system may have come with system memory already
installed. Make sure all DIMMs are fully seated in their slots. For details
on adding system memory, refer to Section 5-6.
5. Installing add-on cards:
If desired, you can install an add-on card to the system. See Section 5-
7 for details on installing a PCI add-on card.
Содержание SUPERSERVER 6021F
Страница 1: ...SUPERSERVER 6021F USER SMANUAL 1 0a SUPER...
Страница 10: ...NOTES SUPERSERVER 6021F User s Manual x...
Страница 30: ...SUPERSERVER 6021F Manual 3 4 NOTES...
Страница 41: ...Chapter 5 Installation 5 7 Installation Figure 5 4 Heat Sink Installation...
Страница 60: ...5 26 SUPERSERVER 6021F User s Manual Installation NOTES...
Страница 69: ...Chapter 6 Advanced Chassis Setup 6 9 Figure 6 6 Chassis Rear View Power Supply I O Shield...
Страница 70: ...6 10 SUPERSERVER 6021F Manual NOTES...
Страница 112: ...SUPERSERVER 6021F User s Manual B 10 APPENDIX B NOTES...
Страница 116: ...SUPERSERVER 6021F User s Manual C 4 Notes...