Supermicro SUPERSERVER 6015TC-10G Скачать руководство пользователя страница 93

Appendix B: BIOS POST Codes

B-1

Appendix B 

BIOS POST Codes

This section lists the POST (Power On Self Test) codes for the PhoenixBIOS. POST 

codes are divided into two categories: recoverable and terminal.

Recoverable POST Errors

When a recoverable type of error occurs, BIOS will display an POST code that 

describes the problem. BIOS may also issue one of the following beep codes:

1 long and two short beeps - video confi guration error

1 repetitive long beep - no memory detected

Terminal POST Errors

If a terminal type of error occurs, BIOS will shut down the system but before doing 

so, will write the error to port 80h, attempt to initialize video and write the error in 

the top left corner of the screen. The following is a list of codes that may be writ-

ten to port 80h.

POST Code   Description

01h    

IPMI Initialization

02h    

Verify Real Mode

03h    

Disable Non-Maskable Interrupt (NMI)

04h    

Get CPU type

06h    

Initialize system hardware

07h    

Disable shadow and execute code from the ROM.

08h    

Initialize chipset with initial POST values

09h    

Set IN POST fl ag

0Ah    

Initialize CPU registers

0Bh    

Enable CPU cache

0Ch    

Initialize caches to initial POST values

0Eh    

Initialize I/O component

0Fh    

Initialize the local bus IDE

10h    

Initialize Power Management

11h    

Load alternate registers with initial POST values

12h    

Restore CPU control word during warm boot

13h    

Reset PCI Bus Mastering devices

14h    

Initialize keyboard controller

16h    

1-2-2-3 BIOS ROM checksum

Содержание SUPERSERVER 6015TC-10G

Страница 1: ...SUPER SUPERSERVER 6015TC T SUPERSERVER 6015TC 10G USER S MANUAL Revision 1 0a...

Страница 2: ...UPERMICRO SHALL NOT HAVE LIABILITY FOR ANY HARDWARE SOFTWARE OR DATA STORED OR USED WITH THE PRODUCT INCLUDING THE COSTS OF REPAIRING REPLACING INTEGRATING INSTALLING OR RECOVERING SUCH HARDWARE SOFTW...

Страница 3: ...chapter provides a checklist of the main components included with the server system and describes the main features of the Super X7DCT X7DCT 10G serverboard and the SC808T 780 chassis Chapter 2 Server...

Страница 4: ...rs Refer to this chapter when adding or removing processors or main memory and when reconfiguring the serverboard Chapter 6 Advanced Chassis Setup Refer to Chapter 6 for detailed information on the SC...

Страница 5: ...v Preface Notes...

Страница 6: ...Panel 1 5 Rear I O Panel 1 5 Cooling System 1 5 1 4 1U Twin System Notes 1 6 System Power 1 6 SATA Backplane Drives 1 6 1 5 Contacting Supermicro 1 7 Chapter 2 Server Installation 2 1 Overview 2 1 2...

Страница 7: ...2 NIC1 3 2 HDD 3 2 Power 3 3 3 4 SATA Drive Carrier LEDs 3 3 Chapter 4 System Safety 4 1 Electrical Safety Precautions 4 1 4 2 General Safety Precautions 4 2 4 3 ESD Precautions 4 3 4 4 Operating Prec...

Страница 8: ...r 6 Advanced Chassis Setup 6 1 Static Sensitive Devices 6 1 Precautions 6 1 Unpacking 6 1 6 2 Control Panel 6 2 6 3 System Fans 6 3 System Fan Failure 6 3 6 4 Drive Bay Installation Removal 6 3 Access...

Страница 9: ...0G as listed below Four 4 CPU heatsinks SNK P0017 SATA Accessories Four 4 SATA hard drive carriers MCP 220 00001 03 01 One 1 internal SATA backplane BPN SAS 808 One 1 SATA cable set CBL 0201L Two 2 PC...

Страница 10: ...hannel configurations All memory modules used to populate the system should be the same size type and speed Serial ATA The South Bridge ICH9R of the chipset includes a Serial ATA controller for six Gb...

Страница 11: ...one set for each serverboard ATI Graphics Controller The X7DCT X7DCT 10G features an integrated ATI video controller based on the ES1000 graphics chip which includes 32 MB of DDR2 memory The ES1000 wa...

Страница 12: ...apter 5 for details USB 2 0 3 0 Gb S Intel 5100 MCH PROCESSOR 2 ICH9R PCI EXP x8 GILGAL GB LAN FWH RJ45 RJ45 LPC SIO W83627GF ATI PCI 33MHz ES1000 VGA CONN KB MS PROCESSOR 1 1067 1333 MT S 1067 1333 M...

Страница 13: ...iated with each serverboard in the chassis Each control panel has LEDs to indicate power on net work activity hard disk drive activity and system overheat conditions Each control panel also includes a...

Страница 14: ...2 C signals used for power supply monitoring are received by the primary serverboard only When viewed from the front of the chassis the serverboard on the left is referred to as the primary board and...

Страница 15: ...per Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical...

Страница 16: ...1 8 SUPERSERVER 6015TC T 6015TC 10G User s Manual Notes...

Страница 17: ...age claim with the carrier who delivered it Decide on a suitable location for the rack unit that will hold the 6015TC T 6015TC 10G It should be situated in a clean dust free area that is well ventilat...

Страница 18: ...rack installation stabilizers should be attached to the rack In multiple rack installations the racks should be coupled together Always make sure the rack is stable before extending a component from...

Страница 19: ...a ture Tmra Reduced Airflow Equipment should be mounted into a rack so that the amount of airflow required for safe operation is not compromised Mechanical Loading Equipment should be mounted into a r...

Страница 20: ...s that came with the rack unit you are using Identifying the Sections of the Rack Rails You should have received two rack rail assemblies in the rack mounting kit Each assembly consists of two section...

Страница 21: ...cket to the front side of the outer rail with two M4 screws and the long bracket to the rear side of the outer rail with three M4 screws Repeat these steps for the left outer rail Locking Tabs Both ch...

Страница 22: ...e two front brackets to each side of the chassis then the two rear brackets positioned with just enough space to accommodate the width of the rack Finish by sliding the chassis into the rack and tight...

Страница 23: ...on processor and heatsink installation Your server system may have come with system memory already installed 2 Make sure all DIMMs are fully seated in their slots For details on adding system memory r...

Страница 24: ...l SATA drives please refer to Chapter 6 Checking the Airflow Airflow is provided by six sets of 4 cm PWM fans each set of fans consists 1 of two fans that are mounted back to back and an air shroud Th...

Страница 25: ...Chapter 2 Server Installation 2 9 Figure 2 4 Accessing the Inside of the System...

Страница 26: ...2 10 SUPERSERVER 6015TC T 6015TC 10G User s Manual Notes...

Страница 27: ...may need to take Note that the server has two control panels one for each serverboard installed in the system This allows each serverboard to be controlled independently of the other 3 2 Control Panel...

Страница 28: ...t condition which may be caused by cables obstructing the airflow in the system or the ambient room temperature being too warm Check the routing of the cables and make sure all fans are present and op...

Страница 29: ...ystem is operating 3 4 SATA Drive Carrier LEDs Each SATA drive carrier has two LEDs Green When illuminated the green LED on the front of the SATA drive carrier indicates drive activity A connection to...

Страница 30: ...3 4 SUPERSERVER 6015TC T 6015TC 10G User s Manual Notes...

Страница 31: ...ng power you should first power down the system with the operating system first and then unplug the power cords of all the power supply units in the system When working around exposed electrical circu...

Страница 32: ...bjects from your body which are excellent metal conductors that can create short circuits and harm you if they come into contact with printed circuit boards or areas where power is present Serverboard...

Страница 33: ...static bags until ready for use Touch a grounded metal object before removing the board from the antistatic bag Do not let components or PCBs come into contact with your clothing which may retain a ch...

Страница 34: ...ure that the chassis cover is in place when the 6015TC T 6015TC 10G is operating to assure proper cooling Out of warranty damage to the system can occur if this practice is not strictly followed Figur...

Страница 35: ...to handle them very carefully see previous chapter To prevent the X7DCT X7DCT 10G serverboard from bending keep one hand under the center of the board to support it when handling The following measure...

Страница 36: ...ls lock into place See Figure 2 5 Check Compatibility of Serverboard Ports and I O Shield The X7DCT X7DCT 10G in a Twin 1U configuration requires the use of 1 Supermicro s specially designed 1U Twin c...

Страница 37: ...the pin 1 locations The following data cables with their locations noted should be connected See the serverboard layout for connector locations Note that each connection listed should be made for bot...

Страница 38: ...cc Reset Button Power Button Ground x Key Power On LED HDD LED NIC1 LED NIC2 LED OH Fan Fail LED Power Fail LED Ground Ground 2 1 20 19 Connecting the Control Panel JF1 contains header pins for variou...

Страница 39: ...certified multi directional heatsinks and fans When purchasing a Xeon CPU or when receiving a serverboard with a CPU 2 pre installed make sure that the CPU plastic cap is in place and none of the CPU...

Страница 40: ...ally or vertically and do not rub the CPU against any sur face or any of the contacts which may damage the CPU and or contacts 7 With the CPU in the socket inspect the four corners of the CPU to make...

Страница 41: ...Screw in two diagonal screws i e the 1 and the 2 screws until just snug Do not fully tighten the screws or you may damage the CPU 4 Add the two remaining screws then finish the installation by fully...

Страница 42: ...ee Figure 5 3 Repeat to install a total of four or six DIMMs 3 CAUTION Exercise extreme care when installing or removing DIMM modules to prevent any possible damage To Install Insert module vertically...

Страница 43: ...locking tab 1 Insert the add on card into the riser card 2 Secure the add on card with the locking tab 3 Possible System Memory Allocation Availability System Device Size Physical Memory Remaining Ava...

Страница 44: ...USB2 3 PCI Exp x16 SGPIO USB4 PWR_BKPlane PWR1 PWR2 COM SATA3 SATA2 SATA1 SATA0 DIMM3A DIMM3B DIMM1A DIMM1B DIMM2A DIMM2B SIMSO CPU1 LAN1 CPU2 LAN2 USB0 1 VGA Battery SPKR LAN CTRL Super I O FP CTLR...

Страница 45: ...abled JWD Watch Dog Pins 1 2 Reset Connector Description COM COM Serial Port FAN 1 3 System Fan Headers I2 C_PWR I2 C Power Connector JF1 Control Panel Header LAN1 2 Gigabit Ethernet RJ45 Ports JF1 Fr...

Страница 46: ...on the right for the pin definitions Only one of the two ATX power connectors from each serverboard should be connected to the power supply Reset Button Pin Definitions JF1 Pin Definition 3 Reset 4 G...

Страница 47: ...Serial ATA and IDE See the table on the right for pin definitions OH Fan Fail LED Pin Definitions JF1 Pin Definition 7 Vcc 8 Ground NIC1 LED Pin Definitions JF1 Pin Definition 11 Vcc 12 Ground NIC2 LE...

Страница 48: ...ers See the table on the right for pin definitions Note The onboard fan speed is con trolled by the CPU die temperature NMI Button The non maskable interrupt button header is located on pins 19 and 20...

Страница 49: ...und 10 NC SGPIO Header An SGPIO Serial General Purpose Input Output header is included on the serverboard This header is used to communicate with the System Monitor ing chip on the backplane to monito...

Страница 50: ...l also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS To Clear CMOS First power down the system and unplug the power cor...

Страница 51: ...og Timer Watch Dog Jumper Settings JWD Jumper Setting Definition Pins 1 2 Reset Pins 2 3 NMI Open Disabled LAN1 LAN2 Enable Disable Change the setting of jumper JPL1 to enable or disable the LAN1 port...

Страница 52: ...en Solid Power On System On Green flashing quickly ACPI S1 State Green flashing slowly ACPI S3 STR State Off Power Off power cable not connected Onboard Power LED LED3 There is an Onboard Power LED LE...

Страница 53: ...er installing each item you must re boot the system before proceeding with the next item on the list The bottom icon with a CD on it allows you to view the entire contents of the CD 5 12 Installing Ad...

Страница 54: ...Doctor III displays crucial system information such as CPU temperature system voltages and fan status See the Figure below for a display of the Supero Doctor III interface Notes The default User Name...

Страница 55: ...ision 1 0 can be downloaded from our Web site at ftp ftp supermicro com utility Supero_Doctor_III You can also download SDIII User s Guide at http www supermicro com PRODUCT Manuals SDIII UserGuide pd...

Страница 56: ...5 22 SUPERSERVER 6015TC T 6015TC 10G User s Manual Notes...

Страница 57: ...ully The following measures are generally sufficient to protect your equipment from ESD discharge Precautions Use a grounded wrist strap designed to prevent static discharge Touch a grounded metal obj...

Страница 58: ...connection Connect the cable from JF1 on the serverboard to the control panel PCB printed circuit board Make sure the red wire plugs into pin 1 on both connectors Pull all excess cabling out of the a...

Страница 59: ...s still running to deter mine which of the fans has failed Then power down the system before replacing a fan Removing the power cord is also recommended as a safety precaution 6 4 Drive Bay Installati...

Страница 60: ...unting a Drive in a Carrier Figure 6 4 Removing a SATA Drive Installing Removing Hot swap SATA Drives To remove a carrier push the release button located beside the drive LEDs 1 Swing the handle fully...

Страница 61: ...n either side and pull the unit straight out until it 1 locks you will hear a click The top cover of the chassis is secured with four screws two at the top rear 2 of the cover and one on each side lip...

Страница 62: ...g the power cord make sure the power switch on the 3 power supply is in the off position Reconnect the power cord replace the chassis top cover and push the unit 4 back into the rack Finish by turning...

Страница 63: ...d off a backup battery pro vides power to the CMOS Logic enabling it to retain system parameters Each time the computer is powered on the computer is configured with the values stored in the CMOS Logi...

Страница 64: ...s 1 By pressing Delete immediately after turning the system on or 2 When the message shown below appears briefly at the bottom of the screen during the POST Power On Self Test press the Delete key to...

Страница 65: ...e Using the arrow keys highlight the month day and year fields and enter the correct data Press the Enter key to save the data BIOS Date This field displays the date when this version of BIOS was buil...

Страница 66: ...lect the type of IDE hard drive The option Auto will allow the BIOS to automatically configure the parameters of the HDD installed at the connection Enter a number between 1 to 39 to select a predeter...

Страница 67: ...Mode The options are Disabled Mode 0 Mode 1 Mode 2 Mode 3 Mode 4 and Mode 5 Serial ATA This setting allows the user to enable or disable the function of the Serial ATA The options are Disabled and En...

Страница 68: ...This display informs you how much system memory is recognized as being present in the system Extended Memory This display informs you how much extended memory is recognized as being pres ent in the s...

Страница 69: ...display POST Error Messages if an error occurs during bootup If set to Disabled the system will continue to boot without displaying any error message even when a boot error occurs ACPI Mode Use the se...

Страница 70: ...ive for more than 5 minutes The options are Enabled and Disabled Summary Screen This setting allows you to Enable or Disable the summary screen which displays the system configuration during bootup XM...

Страница 71: ...ect to prevent data from being written into the base memory area of Block 512 640K Select Write Back to allow the CPU to write data back directly from the buffer without writing data to the System Mem...

Страница 72: ...ve to make changes to the fol lowing Option ROM Scan When enabled this setting will initialize the device expansion ROM The options are Enabled and Disabled Enable Master This setting allows you to en...

Страница 73: ...cialized dedicated processor that is installed on an add on card or a network card to handle some or all packet processing of this add on card For this motherboard the TOE device is built inside the S...

Страница 74: ...source Memory is updated as well Select Enabled to use Demand Scrubbing for ECC memory correction Enable Multi Media Timer Select Yes to activate a set of timers that are alternative to the tradition...

Страница 75: ...ed and Enabled Note For more information regarding hardware software support for this function please refer to Intel s and Microsoft s web sites Adjacent Cache Line Prefetch Available when supported b...

Страница 76: ...use CPU Cache Line IP Prefetch The options are Disabled and Enabled Direct Cache Access Available when supported by the CPU Set to Enable to route inbound network IO traffi c directly into processor...

Страница 77: ...to the following settings Event Log Validity This is a display to inform you of the event log validity It is not a setting Event Log Capacity This is a display to inform you of the event log capacity...

Страница 78: ...0 2400 9600 19 2K 38 4K 57 6K and 115 2K Console Type This item allows you to choose the console redirection type The options are VT100 VT100 8bit PC ANSI 7bit PC ANSI VT100 and VT UTF8 Flow Control T...

Страница 79: ...pin if your chassis came with 3 pin fan headers Select 4 pin if your chas sis came with 4 pin fan headers Select Workstation if your system is used as a Workstation Select Server if your system is use...

Страница 80: ...t Logging When this function is set to Disabled the system will continue to log events received via system interface The options are Enabled and Disabled Clear System Event Logging Enabling this funct...

Страница 81: ...nutes This feature allows the user to set the time value in minutes for the previous item OS Boot Watch Dog by keying in a desired number in the blank The default set ting is 10 minutes Please ignore...

Страница 82: ...ures fan speeds and voltages of various components 7 5 Security Choose Security from the Phoenix BIOS Setup Utility main menu with the arrow keys You should see the following display Security setting...

Страница 83: ...has not been used and Set means a user password has been entered for the system Set Supervisor Password When the item Set Supervisor Password is highlighted hit the Enter key When prompted type the Su...

Страница 84: ...list section above are bootable devices listed in the sequence of boot order as specified The boot functions for the devices included in the candidate list above are currently disabled Use a key or a...

Страница 85: ...changes you made and to exit the BIOS Setup utility Exit Discarding Changes Highlight this item and hit Enter to exit the BIOS Setup utility without saving any changes you may have made Load Setup Def...

Страница 86: ...7 24 SUPERSERVER 6015TC T 6015TC 10G User s Manual Save Changes Highlight this item and hit Enter to save any changes you made You will remain in the Setup utility...

Страница 87: ...d Keyboard controller failed test May require replacing keyboard controller Keyboard locked Unlock key switch Unlock the system to proceed Monitor type does not match CMOS Run SETUP Monitor type not c...

Страница 88: ...up If the failure was caused by incorrect values and they are not corrected the next boot will likely fail On systems with control of wait states improper Setup settings can also terminate POST and ca...

Страница 89: ...error Fail Safe Timer takes too long device Address Conflict Address conflict for specified device Allocation Error for device Run ISA or EISA Configuration Utility to resolve resource conflict for th...

Страница 90: ...em not found Operating system cannot be located on either drive A or drive C Enter Setup and see if fixed disk and drive A are properly identified Parity Check 1 nnnn Parity error found in the system...

Страница 91: ...devices have the Configuration Request bit set in the LCT Run an I2O Configuration Utility e g the SAC utility System BIOS shadowed System BIOS copied to shadow RAM UMB upper limit segment address nnn...

Страница 92: ...A 6 SUPERSERVER 6015TC T 6015TC 10G User s Manual Notes...

Страница 93: ...tempt to initialize video and write the error in the top left corner of the screen The following is a list of codes that may be writ ten to port 80h POST Code Description 01h IPMI Initialization 02h V...

Страница 94: ...ger 36h Warm start shut down 38h Shadow system BIOS ROM 3Ah Auto size cache 3Ch Advanced configuration of chipset registers 3Dh Load alternate registers with CMOS values 41h Initialize extended memory...

Страница 95: ...nd IRQs optional 81h Late POST device initialization 82h Detect and install external RS232 ports 83h Configure non MCD IDE controllers 84h Detect and install external parallel ports 85h Initialize PC...

Страница 96: ...inate QuietBoot optional B6h Check password optional B7h Initialize ACPI BIOS and PPM Structures B9h Prepare Boot BAh Initialize SMBIOS BCh Clear parity checkers BDh Display MultiBoot menu BEh Clear s...

Страница 97: ...terrupt vectors F1h Initialize Run Time Clock F2h Initialize video F3h Initialize System Management Manager F4h Output one beep F5h Clear Huge Segment F6h Boot to Mini DOS F7h Boot to Full DOS If the...

Страница 98: ...B 6 SUPERSERVER 6015TC T 6015TC 10G User s Manual Notes...

Страница 99: ...slots to support a maximum up to 96 GB of registered ECC DDR2 667 533 SDRAM Note interleaved memory requires DIMMs to be installed in pairs refer to Section 5 6 for details Serial ATA Controller Intel...

Страница 100: ...emperature 40 to 70 C 40 to 158 F Operating Relative Humidity 8 to 90 non condensing Non operating Relative Humidity 5 to 95 non condensing Regulatory Compliance Electromagnetic Emissions FCC Class A...

Страница 101: ...C 3 Appendix C System Specifications Notes...

Страница 102: ...to perform be reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro dis claims any and all liability and should buyer use or sell s...