Chapter 7: BIOS
7-15
Console Connection
Select the console connection: either
Direct
or Via Modem.
Continue CR after POST
This option allows the user to decide whether to continue with console
redirection after the POST routine. The options are On and
Off
.
Hardware Monitor Logic
CPU Temperature Threshold
This option allows the user to set a CPU temperature threshold that will activate
the alarm system when the CPU temperature reaches this pre-set temperature
threshold. The options are 75
o
C,
80
o
C
, 85
o
C and 90
o
C.
Highlight this and hit <Enter> to see the status of the following items:
CPU1 Temperature
:
This item displays CPU1 Temperature.
CPU2 Temperature
:
This item displays CPU2 Temperature.
System Temperature
:
This item displays the system Temperature.
Fan Speed Control Modes:
[Disable (Full Speed),
3-pin (Server)
]
This feature allows the user to decide how the system controls the speeds of onboard
fans. Select "Disable" to disable of the function of fan speed control and the system
will run at the full speed (12V.) Select "3-pin Server" to optimize the fan speed control
via BIOS Thermal management. The default setting is
3-pin Server
.
Fan 1/ Fan 2/Fan 3/Fan 4/Fan 5
The voltage status of the following items will also be displayed:
Vcore A
Vcore B
P3V3
P5V
N12V
P12V
VDD
P5Vsb
Содержание SUPERSERVER 6014H-32
Страница 1: ...SUPERSERVER 6014H 32 USER S MANUAL 1 0a SUPER...
Страница 5: ...v Preface Notes...
Страница 10: ...SUPERSERVER 6014H 32 User s Manual x Notes...
Страница 30: ...3 4 SUPERSERVER 6014H 32 User s Manual Notes...
Страница 66: ...6 10 SUPERSERVER 6014H 32 User s Manual Figure 6 6 Removing Replacing the Power Supply...
Страница 86: ...7 20 SUPERSERVER 6014H 32 User s Manual Notes...
Страница 92: ...A 6 SUPERSERVER 6014H 32 User s Manual Notes...
Страница 126: ...C 4 SUPERSERVER 6014H 32 User s Manual Notes...